arXiv:1102.1797 · Physical Review Letters

Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10−17 Level

Philip G. Westergaard, Jérôme Lodewyck, L. Lorini, Arnaud Lecallier, Eric A. Burt, M. Zawada, Jacques Millo, P. Lemonde

Published May 23, 2011• 140 citations
arXivHTMLPDF

Abstract

We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5×10(-17) after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice related perturbations will not affect the clock accuracy down to the 10(-17) level, even for lattices as deep as 150 recoil energies.

DOI
10.1103/physrevlett.106.210801

Related papers

Trapping induced frequency shifts by comparison of two Sr optical lattice clocks at the 10−17 level

Jérôme Lodewyck, Philip G. Westergaard, L. Lorini +4 more

We present a comprehensive study of the frequency shifts associated with the lattice potential in Sr lattice clocks. By comparing two such clocks with a frequency stability better than 5.10-17after one hour of averaging time, and varying the lattice depth up to U0= 900 Erwith Erbeing the recoil energy, we evaluate lattice related shifts with an unprecedented accuracy.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2011•0 citations

Operational Magic Intensity for Sr Optical Lattice Clocks

Ichiro Ushijima, Masao Takamoto, Hidetoshi Katori

We experimentally investigate the lattice-induced light shift by the electric-quadrupole (E2) and magnetic-dipole (M1) polarizabilities and the hyperpolarizability in Sr optical lattice clocks. Precise control of the axial as well as the radial motion of atoms in a one-dimensional lattice allows observing the E2-M1 polarizability difference. Measured polarizabilities determine an operational lattice depth to be 72(2)E_{R}, where the total light shift cancels to the 10^{-19} level, over a lattice-intensity variation of about 30%. This operational trap depth and its allowable intensity range conveniently coincide with experimentally feasible operating conditions for Sr optical lattice clocks.

arXiv:1812.11815•Physical Review Letters•Dec 28, 2018•116 citations

Hyperpolarizability Effects in a Sr Optical Lattice Clock

Anders Brusch, Rodolphe Le Targat, Xavier Baillard +2 more

We report the observation of a higher-order frequency shift due to the trapping field in a (87)Sr optical lattice clock. We show that, at the magic wavelength of the lattice, where the first-order term cancels, the higher-order shift will not constitute a limitation to the fractional accuracy of the clock at a level of 10(-18). This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm(2) and by a specific study of the effect of the two two-photon transitions near the magic wavelength.

arXiv:physics/0512201•Physical Review Letters•Mar 16, 2006•121 citations

Compensation of the multipolar polarizability shift in optical lattice clocks

Artem A. Golovizin

In neutral atom optical clocks, the higher-order atomic polarizability terms lead to the clock transition frequency shift that is motion-state dependent and nonlinear with the optical lattice depth. We propose to use an auxiliary optical lattice to compensate the influence of the E2–M1 differential polarizability or tune the associated coefficient to a favorable value. We show that by applying this method to Sr and Hg optical lattice clocks, the low or even sub-10 −19 clock transition frequency uncertainty from the optical lattice becomes feasible. Finally, the proposed scheme is simple for experimental realization, is compatible with the use of an enhancement cavity, and can be implemented and tested in the existing setups.

arXiv:2402.02550•Optics Letters•May 8, 2024•0 citations

OPTICAL LATTICE CLOCK WITH Sr ATOMS

Philip G. Westergaard, Arnaud Lecallier, Jérôme Lodewyck +1 more

We review the recent progress at LNE-SYRTE on an optical lattice clock using Sr atoms. We discuss the required lattice depth to cancel motional effects in such a clock and show that a relatively small lattice depth is sufficient provided the lattice is oriented vertically. We also demonstrate an accurate frequency measurement of the Sr clock transition with accuracy in the low 10 -15 range. Finally, we describe a new non-destructive method to detect the atoms in the clock and discuss the expected associated improvement in the frequency stability of the clock.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

Hyperpolarizability and Operational Magic Wavelength in an Optical Lattice Clock

Roger C. Brown, Nate Phillips, K. Beloy +11 more

Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.

arXiv:1708.08829•Physical Review Letters•Dec 19, 2017•106 citations
We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5×10(-17) after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice related perturbations will not affect the clock accuracy down to the 10(-17) level, even for lattices as deep as 150 recoil energies.
We experimentally investigate the lattice-induced light shift by the electric-quadrupole (E2) and magnetic-dipole (M1) polarizabilities and the hyperpolarizability in Sr optical lattice clocks. Precise control of the axial as well as the radial motion of atoms in a one-dimensional lattice allows observing the E2-M1 polarizability difference. Measured polarizabilities determine an operational lattice depth to be 72(2)E_{R}, where the total light shift cancels to the 10^{-19} level, over a lattice-intensity variation of about 30%. This operational trap depth and its allowable intensity range conveniently coincide with experimentally feasible operating conditions for Sr optical lattice clocks.
We report the observation of a higher-order frequency shift due to the trapping field in a (87)Sr optical lattice clock. We show that, at the magic wavelength of the lattice, where the first-order term cancels, the higher-order shift will not constitute a limitation to the fractional accuracy of the clock at a level of 10(-18). This result is achieved by operating the clock at very high trapping intensity up to 400 kW/cm(2) and by a specific study of the effect of the two two-photon transitions near the magic wavelength.
In neutral atom optical clocks, the higher-order atomic polarizability terms lead to the clock transition frequency shift that is motion-state dependent and nonlinear with the optical lattice depth. We propose to use an auxiliary optical lattice to compensate the influence of the E2–M1 differential polarizability or tune the associated coefficient to a favorable value. We show that by applying this method to Sr and Hg optical lattice clocks, the low or even sub-10 −19 clock transition frequency uncertainty from the optical lattice becomes feasible. Finally, the proposed scheme is simple for experimental realization, is compatible with the use of an enhancement cavity, and can be implemented and tested in the existing setups.
We review the recent progress at LNE-SYRTE on an optical lattice clock using Sr atoms. We discuss the required lattice depth to cancel motional effects in such a clock and show that a relatively small lattice depth is sufficient provided the lattice is oriented vertically. We also demonstrate an accurate frequency measurement of the Sr clock transition with accuracy in the low 10 -15 range. Finally, we describe a new non-destructive method to detect the atoms in the clock and discuss the expected associated improvement in the frequency stability of the clock.
Optical clocks benefit from tight atomic confinement enabling extended interrogation times as well as Doppler- and recoil-free operation. However, these benefits come at the cost of frequency shifts that, if not properly controlled, may degrade clock accuracy. Numerous theoretical studies have predicted optical lattice clock frequency shifts that scale nonlinearly with trap depth. To experimentally observe and constrain these shifts in an ^{171}Yb optical lattice clock, we construct a lattice enhancement cavity that exaggerates the light shifts. We observe an atomic temperature that is proportional to the optical trap depth, fundamentally altering the scaling of trap-induced light shifts and simplifying their parametrization. We identify an "operational" magic wavelength where frequency shifts are insensitive to changes in trap depth. These measurements and scaling analysis constitute an essential systematic characterization for clock operation at the 10^{-18} level and beyond.