Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Symposium on Frequency Standards and Metrology

OPTICAL LATTICE CLOCK WITH Sr ATOMS

Philip G. Westergaard, Arnaud Lecallier, Jérôme Lodewyck, P. Lemonde

Published May 1, 2009• 0 citations
Publisher

Abstract

We review the recent progress at LNE-SYRTE on an optical lattice clock using Sr atoms. We discuss the required lattice depth to cancel motional effects in such a clock and show that a relatively small lattice depth is sufficient provided the lattice is oriented vertically. We also demonstrate an accurate frequency measurement of the Sr clock transition with accuracy in the low 10 -15 range. Finally, we describe a new non-destructive method to detect the atoms in the clock and discuss the expected associated improvement in the frequency stability of the clock.

DOI
10.1142/9789812838223_0022

Related papers

AN OPTICAL LATTICE CLOCK: ULTRASTABLE ATOMIC CLOCK WITH ENGINEERED PERTURBATION

Hidetoshi Katori, Masao Takamoto, Ryoichi Higashi +1 more

An optical lattice clock was realized for 87 Sr atoms and its absolute frequency has been measured. Projected uncertainty in the lattice clock is illustrated for the case of 87 Sr . We discuss application of the clock scheme to other atom species, in search for better lattice clocks as well as for the variation of fine-structure constant.

Foundations of Quantum Mechanics in the Light of New Technology•Jun 1, 2006•0 citations

OPTICAL LATTICE CLOCK: SEVEN YEARS OF PROGRESS AND NEXT STEPS

Hidetoshi Katori, Masao Takamoto, Tomoya Akatsuka

We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.

Symposium on Frequency Standards and Metrology•May 1, 2009•0 citations

SR OPTICAL CLOCK WITH HIGH STABILITY AND ACCURACY

Andrew D. Ludlow, Sebastian Blatt, M. BOYD +12 more

We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16

Laser Spectroscopy•Apr 1, 2008•0 citations

Frequency stability of optical lattice clocks

Jérôme Lodewyck, Philip G. Westergaard, Arnaud Lecallier +2 more

In this paper, we review several aspects of the frequency stability of optical lattice clocks. We describe a new ultra-stable cavity design with reduced thermal noise and record frequency stability (below 10 −15 ), as well as a non-destructive detection scheme for measuring the clock transition probability. Given the experimental parameters we measured, we simulate different sequence strategies for optimizing the stability. Finally, we report on the development of a second optical lattice clock and simulate several comparison strategies. In particular, we show by a numerical method that a stability as low as 2 × 10 −16 τ −1/2 can be reached with optical lattice clocks, and we show how to demonstrate this stability with a double clock system.

New Journal of Physics•Jun 28, 2010•33 citations

Developments to improve the stability of optical lattice clocks

S. Bize, Bess Fang, Yann Le Coq +5 more

Abstract We present several developments aimed at improving the stability of optical lattice clocks. First, we present our developments of an optical lattice clock using neutral mercury. We mention recent advances made with the fermionic isotope 199Hg. We also mention our work aimed at using bosonic isotopes, which offer the possibility to circumvent the relatively short lifetime of the upper clock state in 199Hg. Second, we present our work on a non-destructive detection in a Sr optical lattice clock. We describe developments that brought the detection scheme from the classical non-destructive regime to the quantum non-destructive regime. Our detection scheme is practical and has the capability to the used beyond proving the principle. Finally, we present our work on laser stabilization using spectral hole burning in a Eu3+:Y2SiO5 crystal at cryogenic temperatures. We describe our development of low noise interrogation based on digital IQ modulation and detection that can probe multiple spectral features simultaneously, as well as several investigations towards fluctuating environmental factors. These advances, individually or combined for example with spectral purity transfer with combs and composite clock approaches, shall bring significant progress in clock stability and accuracy.

Journal of Physics Conference Series•Nov 1, 2024•1 citation

OPTICAL LATTICE CLOCK: PRECISION SPECTROSCOPY OF NEUTRAL ATOMS IN TIGHT CONFINEMENT

Hidetoshi Katori, Masao Takamoto

We report on the spectroscopy of the 5s 2 1 S 0 (F = 9/2) → 5s5p 3 P 0 (F = 9/2) clock transition of 87 Sr atoms (natural linewidth of 1 mHz) trapped in a one-dimensional optical lattice. A recoilless transition with a linewidth of 0.7 kHz was observed for the trap laser wavelength λ ≈ 813 nm, where the light shift in the clock transition canceled out. We discuss the feasibility of realizing an optical frequency standard based on this scheme.

Laser Spectroscopy•Feb 1, 2004•0 citations
We review the recent progress at LNE-SYRTE on an optical lattice clock using Sr atoms. We discuss the required lattice depth to cancel motional effects in such a clock and show that a relatively small lattice depth is sufficient provided the lattice is oriented vertically. We also demonstrate an accurate frequency measurement of the Sr clock transition with accuracy in the low 10 -15 range. Finally, we describe a new non-destructive method to detect the atoms in the clock and discuss the expected associated improvement in the frequency stability of the clock.
We discuss configurations of optical lattice clocks from the viewpoint of lattice geometries and quantum statistics of interrogated atoms. This leads to two promising schemes: a one-dimensional lattice loaded with spin-polarized fermions and a three-dimensional lattice loaded with bosons. These two optical lattice clocks based on fermionic 87 Sr and bosonic 88 Sr were demonstrated by measuring the frequency stability as well as their isotope shift. In addition, we address the ongoing experimental challenges for optical lattice clocks.
We report on our recent evaluations of stability and accuracy of the JILA Sr optical lattice clock. We discuss precision tools for the lattice clock, including a stabilized clock laser with sub-Hz linewidth, fs-comb based technology allowing accurate clock comparison in both the microwave and optical domains, and clock transfer over optical fiber in an urban environment. High resolution spectroscopy (Q > 2 × 10^14) of lattice-confined, spin-polarized strontium atoms is used for both a high-performance optical clock and atomic structure measurement. Using a Ca optical standard for comparison, the overall systematic uncertainty of the Sr clock is reduced to < 2 × 10^−16
In this paper, we review several aspects of the frequency stability of optical lattice clocks. We describe a new ultra-stable cavity design with reduced thermal noise and record frequency stability (below 10 −15 ), as well as a non-destructive detection scheme for measuring the clock transition probability. Given the experimental parameters we measured, we simulate different sequence strategies for optimizing the stability. Finally, we report on the development of a second optical lattice clock and simulate several comparison strategies. In particular, we show by a numerical method that a stability as low as 2 × 10 −16 τ −1/2 can be reached with optical lattice clocks, and we show how to demonstrate this stability with a double clock system.
Abstract We present several developments aimed at improving the stability of optical lattice clocks. First, we present our developments of an optical lattice clock using neutral mercury. We mention recent advances made with the fermionic isotope 199Hg. We also mention our work aimed at using bosonic isotopes, which offer the possibility to circumvent the relatively short lifetime of the upper clock state in 199Hg. Second, we present our work on a non-destructive detection in a Sr optical lattice clock. We describe developments that brought the detection scheme from the classical non-destructive regime to the quantum non-destructive regime. Our detection scheme is practical and has the capability to the used beyond proving the principle. Finally, we present our work on laser stabilization using spectral hole burning in a Eu3+:Y2SiO5 crystal at cryogenic temperatures. We describe our development of low noise interrogation based on digital IQ modulation and detection that can probe multiple spectral features simultaneously, as well as several investigations towards fluctuating environmental factors. These advances, individually or combined for example with spectral purity transfer with combs and composite clock approaches, shall bring significant progress in clock stability and accuracy.