Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2402.02550 · Optics Letters

Compensation of the multipolar polarizability shift in optical lattice clocks

Artem A. Golovizin

Published May 8, 2024• 0 citations
arXivHTMLPDF

Abstract

In neutral atom optical clocks, the higher-order atomic polarizability terms lead to the clock transition frequency shift that is motion-state dependent and nonlinear with the optical lattice depth. We propose to use an auxiliary optical lattice to compensate the influence of the E2–M1 differential polarizability or tune the associated coefficient to a favorable value. We show that by applying this method to Sr and Hg optical lattice clocks, the low or even sub-10 −19 clock transition frequency uncertainty from the optical lattice becomes feasible. Finally, the proposed scheme is simple for experimental realization, is compatible with the use of an enhancement cavity, and can be implemented and tested in the existing setups.

DOI
10.1364/ol.524104

Related papers

Higher-order effects on the precision of clocks of neutral atoms in optical lattices

Vitalii D Ovsiannikov, S. I. Marmo, Vitalii G Pal'chikov +1 more

The recent progress in designing optical lattice clocks with fractional uncertainties below ${10}^{\ensuremath{-}17}$ requires unprecedented precision in estimating the role of higher-order effects of atom-lattice interactions. In this paper, we present results of systematic theoretical evaluations of the multipole, nonlinear, and anharmonic effects on the optical-lattice-based clocks of alkaline-earth-like atoms. Modifications of the model-potential approach are introduced to minimize discrepancies of theoretical evaluations from the most reliable experimental data. Dipole polarizabilities, hyperpolarizabilities, and multipolar polarizabilities for neutral Ca, Sr, Yb, Zn, Cd, and Hg atoms are calculated in the modified approach.

Physical Review A•Apr 26, 2016•29 citations

Nonlinear optical higher-order effects in an optical lattice clock

V. D. Ovsyannikov, S. I. Marmo, Sergey N. Mokhnenko +1 more

The development of optical frequency standards with a relative uncertainty of reproducing the time and frequency units at a level as low as 10 −17 –10 −18 calls for an unprecedented accuracy in estimating the role of higher orders of optical nonlinearity, caused by the influence of the optical lattice on the frequency shift of the 'clock transition'. This paper presents a systematic calculation of the contributions of multipole nonlinear anharmonic effects to the error of clocks based on optical lattices for alkaline-earth-like Sr, Yb, and Hg atoms.

Quantum Electronics•May 9, 2017•0 citations

Strategies for reducing the light shift in atomic clocks

Hidetoshi Katori, Vitalii D Ovsiannikov, S. I. Marmo +1 more

Recent progress in optical lattice clocks requires unprecedented precision in controlling systematic uncertainties at the ${10}^{\ensuremath{-}18}$ level. Tuning of nonlinear light shifts is shown to reduce lattice-induced clock shift for a wide range of lattice intensity. Based on theoretical multipolar, nonlinear, anharmonic, and higher-order light shifts, we numerically demonstrate possible strategies for Sr, Yb, and Hg clocks to achieve lattice-induced systematic uncertainty below $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$.

arXiv:1503.07633•Physical Review A•May 14, 2015•79 citations

Operational Magic Intensity for Sr Optical Lattice Clocks

Ichiro Ushijima, Masao Takamoto, Hidetoshi Katori

We experimentally investigate the lattice-induced light shift by the electric-quadrupole (E2) and magnetic-dipole (M1) polarizabilities and the hyperpolarizability in Sr optical lattice clocks. Precise control of the axial as well as the radial motion of atoms in a one-dimensional lattice allows observing the E2-M1 polarizability difference. Measured polarizabilities determine an operational lattice depth to be 72(2)E_{R}, where the total light shift cancels to the 10^{-19} level, over a lattice-intensity variation of about 30%. This operational trap depth and its allowable intensity range conveniently coincide with experimentally feasible operating conditions for Sr optical lattice clocks.

arXiv:1812.11815•Physical Review Letters•Dec 28, 2018•116 citations

Higher-order shifts of a clock frequency in Sr, Yb and Hg atoms trapped in an optical lattice

Vitalii D Ovsiannikov, Vitalii G Pal'chikov, Hidetoshi Katori

The recent progress in designing optical frequency standards with an uncertainty at a level of 10-17-10-18 requires unprecedented accuracy in estimating the role of higher-order uncertainties of optical clocks. In this paper, we systematically evaluate the multipole, nonlinear, anharmonic contributions to uncertainty of the optical-lattice-based clocks of alkaline-earth-like-atoms Sr, Yb and Hg.

European Frequency and Time Forum•Jun 1, 2014•0 citations

Lattice-Induced Frequency Shifts in Sr Optical Lattice Clocks at the 10−17 Level

Philip G. Westergaard, Jérôme Lodewyck, L. Lorini +5 more

We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5×10(-17) after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice related perturbations will not affect the clock accuracy down to the 10(-17) level, even for lattices as deep as 150 recoil energies.

arXiv:1102.1797•Physical Review Letters•May 23, 2011•140 citations
In neutral atom optical clocks, the higher-order atomic polarizability terms lead to the clock transition frequency shift that is motion-state dependent and nonlinear with the optical lattice depth. We propose to use an auxiliary optical lattice to compensate the influence of the E2–M1 differential polarizability or tune the associated coefficient to a favorable value. We show that by applying this method to Sr and Hg optical lattice clocks, the low or even sub-10 −19 clock transition frequency uncertainty from the optical lattice becomes feasible. Finally, the proposed scheme is simple for experimental realization, is compatible with the use of an enhancement cavity, and can be implemented and tested in the existing setups.
The recent progress in designing optical lattice clocks with fractional uncertainties below ${10}^{\ensuremath{-}17}$ requires unprecedented precision in estimating the role of higher-order effects of atom-lattice interactions. In this paper, we present results of systematic theoretical evaluations of the multipole, nonlinear, and anharmonic effects on the optical-lattice-based clocks of alkaline-earth-like atoms. Modifications of the model-potential approach are introduced to minimize discrepancies of theoretical evaluations from the most reliable experimental data. Dipole polarizabilities, hyperpolarizabilities, and multipolar polarizabilities for neutral Ca, Sr, Yb, Zn, Cd, and Hg atoms are calculated in the modified approach.
The development of optical frequency standards with a relative uncertainty of reproducing the time and frequency units at a level as low as 10 −17 –10 −18 calls for an unprecedented accuracy in estimating the role of higher orders of optical nonlinearity, caused by the influence of the optical lattice on the frequency shift of the 'clock transition'. This paper presents a systematic calculation of the contributions of multipole nonlinear anharmonic effects to the error of clocks based on optical lattices for alkaline-earth-like Sr, Yb, and Hg atoms.
Recent progress in optical lattice clocks requires unprecedented precision in controlling systematic uncertainties at the ${10}^{\ensuremath{-}18}$ level. Tuning of nonlinear light shifts is shown to reduce lattice-induced clock shift for a wide range of lattice intensity. Based on theoretical multipolar, nonlinear, anharmonic, and higher-order light shifts, we numerically demonstrate possible strategies for Sr, Yb, and Hg clocks to achieve lattice-induced systematic uncertainty below $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}18}$.
We experimentally investigate the lattice-induced light shift by the electric-quadrupole (E2) and magnetic-dipole (M1) polarizabilities and the hyperpolarizability in Sr optical lattice clocks. Precise control of the axial as well as the radial motion of atoms in a one-dimensional lattice allows observing the E2-M1 polarizability difference. Measured polarizabilities determine an operational lattice depth to be 72(2)E_{R}, where the total light shift cancels to the 10^{-19} level, over a lattice-intensity variation of about 30%. This operational trap depth and its allowable intensity range conveniently coincide with experimentally feasible operating conditions for Sr optical lattice clocks.
We present a comprehensive study of the frequency shifts associated with the lattice potential in a Sr lattice clock by comparing two such clocks with a frequency stability reaching 5×10(-17) after a 1 h integration time. We put the first experimental upper bound on the multipolar M1 and E2 interactions, significantly smaller than the recently predicted theoretical upper limit, and give a 30-fold improved upper limit on the effect of hyperpolarizability. Finally, we report on the first observation of the vector and tensor shifts in a Sr lattice clock. Combining these measurements, we show that all known lattice related perturbations will not affect the clock accuracy down to the 10(-17) level, even for lattices as deep as 150 recoil energies.