All optical sensor for automated magnetometry based on coherent population trapping

Jacopo Belfi, G. Bevilacqua, V. Biancalana, Yordanka V. Dancheva, L. Moi

Published Jun 15, 2007• 36 citations
arXivHTMLPDF

Abstract

An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on coherent population trapping (CPT) produced by a multifrequency excitation. CPT resonance is observed when a frequency comb, generated by diode laser current modulation, excites Cs atoms confined in a π/4×(2.5)2×1 cm3, 2 TorrN2 buffered cell. A fully optical sensor is connected through an optical fiber to the laser head allowing for truly remote sensing and minimization of the field perturbation. A detailed analysis of the CPT resonance parameters as a function of the optical detuning has been made in order to get high sensitivity measurements. The magnetic field monitoring performances and the best sensitivity obtained in a balanced differential configuration of the sensor are presented.

DOI
10.1364/josab.24.001482

Related papers

All optical automated magnetic field monitoring based on coherent population trapping produced by a frequency-modulated diode laser

Jacopo Belfi, G. Bevilacqua, V. Biancalana +2 more

A fully automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) effect produced by a multi-frequency excitation. It has an all optical sensor connected only by an optical fiber to the laser head. This allows truly remote sensing and minimization of the field perturbation. The CPT resonance is observed when a frequency comb, generated by a diode laser current modulation, excites a sample of Cs atoms confined in a cell with 2 Torr of buffer gas. In differential sensor configuration, allowing for common-mode noise cancellation, the sensitivity of 45pT/square root of Hz is obtained.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 2, 2007•0 citations

Loop-locked coherent population trapping magnetometer based on a fiber electro-optic modulator

Yong Hu, Y. Y. Feng, Chi Xu +2 more

We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.

Applied Optics•Mar 27, 2014•11 citations

Synchronous coherent population trapping for remote magnetic field measurement

Renu Tripathi, Raghwinder Singh Grewal, G. S. Pati +1 more

We demonstrate a new mechanism, suitable for performing remote earth field measurement using synchronous modulation of two laser fields, which are two-photon resonant with the sodium atom’s hyperfine ground states. This mechanism relies on coherent population trapping (CPT), and thus, called the synchronous CPT scheme. We have measured the magnetic resonances in fluorescence from a sodium cell to demonstrate suitability of this scheme for remote magnetometry. A strong magnetic resonance with its dip corresponding to the Larmor frequency is produced in the presence of a transverse magnetic field. To estimate the optimal duty cycle of light modulation for attaining high performance, we measured the amplitudes and linewidths of the magnetic resonance as a function of the duty cycle, by keeping the peak intensity in CPT fields constant.

Optical and Quantum Sensing and Precision Metrology•Mar 4, 2021•0 citations

Miniaturized laser magnetometers and clocks

R. Wynands, C. Affolderbach, Leo W. Hollberg +3 more

We have experimentally investigated the potential of narrow coherent population trapping (CPT) resonances for precision applications like magnetometry or atomic frequency standards, using the D lines in thermal Cs or Rb vapor. The magnetometer operates by monitoring the position of the Zeeman-shifted outermost resonance component. The central Zeeman component is well suited for frequency standard applications because its position is shifted by magnetic fields only in second order. We derive the required pair of laser fields form a special diode laser by direct modulation of the injection current. Magneto metric sensitivity down to a picotesla and 10-12 relative instability for a finger-sized clock have been achieved in this way. Use of a magnetic gradiometer allows to cancel fluctuations of ambient magnetic fields to a large degree, making possible sensitive measurements even outside magnetically shielded rooms.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Apr 3, 2002•1 citation

Remotely-sensed atomic magnetometry

Christopher J. Sataline

Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.

•Jan 1, 2013•0 citations

Magnetic Field Measurement Using Peak-Locked Zeeman Coherent Population Trapping Resonance in Rubidium Vapor

Renu Tripathi, G. S. Pati

A sensor for magnetic field measurement is developed using a small (centimeter size) rubidium cell. A high contrast Zeeman coherent population trapping (CPT) resonance is produced by the magnetic dither in the sensor solenoid, and a peak-locked servo is implemented for magnetic field measurement. Sensitivity close to 110 pT/ √Hz has been achieved in axial field measurement. The CPT-based magnetic sensor is capable of measuring sub-nanotesla level magnetic field variations at high (microtesla) field strength. We discussed possible sources of noise and broadening which are affecting the performance of the sensor, and suggest changes that will further improve the performance of the sensor.

IEEE photonics journal•Jun 13, 2019•8 citations
An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on coherent population trapping (CPT) produced by a multifrequency excitation. CPT resonance is observed when a frequency comb, generated by diode laser current modulation, excites Cs atoms confined in a π/4×(2.5)2×1 cm3, 2 TorrN2 buffered cell. A fully optical sensor is connected through an optical fiber to the laser head allowing for truly remote sensing and minimization of the field perturbation. A detailed analysis of the CPT resonance parameters as a function of the optical detuning has been made in order to get high sensitivity measurements. The magnetic field monitoring performances and the best sensitivity obtained in a balanced differential configuration of the sensor are presented.
A fully automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) effect produced by a multi-frequency excitation. It has an all optical sensor connected only by an optical fiber to the laser head. This allows truly remote sensing and minimization of the field perturbation. The CPT resonance is observed when a frequency comb, generated by a diode laser current modulation, excites a sample of Cs atoms confined in a cell with 2 Torr of buffer gas. In differential sensor configuration, allowing for common-mode noise cancellation, the sensitivity of 45pT/square root of Hz is obtained.
We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.
We demonstrate a new mechanism, suitable for performing remote earth field measurement using synchronous modulation of two laser fields, which are two-photon resonant with the sodium atom’s hyperfine ground states. This mechanism relies on coherent population trapping (CPT), and thus, called the synchronous CPT scheme. We have measured the magnetic resonances in fluorescence from a sodium cell to demonstrate suitability of this scheme for remote magnetometry. A strong magnetic resonance with its dip corresponding to the Larmor frequency is produced in the presence of a transverse magnetic field. To estimate the optimal duty cycle of light modulation for attaining high performance, we measured the amplitudes and linewidths of the magnetic resonance as a function of the duty cycle, by keeping the peak intensity in CPT fields constant.
We have experimentally investigated the potential of narrow coherent population trapping (CPT) resonances for precision applications like magnetometry or atomic frequency standards, using the D lines in thermal Cs or Rb vapor. The magnetometer operates by monitoring the position of the Zeeman-shifted outermost resonance component. The central Zeeman component is well suited for frequency standard applications because its position is shifted by magnetic fields only in second order. We derive the required pair of laser fields form a special diode laser by direct modulation of the injection current. Magneto metric sensitivity down to a picotesla and 10-12 relative instability for a finger-sized clock have been achieved in this way. Use of a magnetic gradiometer allows to cancel fluctuations of ambient magnetic fields to a large degree, making possible sensitive measurements even outside magnetically shielded rooms.
Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.
A sensor for magnetic field measurement is developed using a small (centimeter size) rubidium cell. A high contrast Zeeman coherent population trapping (CPT) resonance is produced by the magnetic dither in the sensor solenoid, and a peak-locked servo is implemented for magnetic field measurement. Sensitivity close to 110 pT/ √Hz has been achieved in axial field measurement. The CPT-based magnetic sensor is capable of measuring sub-nanotesla level magnetic field variations at high (microtesla) field strength. We discussed possible sources of noise and broadening which are affecting the performance of the sensor, and suggest changes that will further improve the performance of the sensor.