Remotely-sensed atomic magnetometry

Christopher J. Sataline

Published Jan 1, 2013• 0 citations
OpenAlex

Abstract

Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.

Related papers

High-temperature lithium atomic magnetometry by symmetric hyperfine coherent population trapping resonances

Kiyoshi Ishikawa

A glass lithium vapor cell is an atomic sensor operating at high temperature. The longitudinal magnetic-field strength is measured by coherent population trapping (CPT) in ground-state hyperfine levels. Two linearly polarized light beams are polarized orthogonally to each other. The difference of optical frequencies is tuned to generate a dark state. Additionally, a few light modes of equidistant frequency spacing are generated by modulating the difference frequency. The symmetry of the light modes and the energy levels enables simultaneous measurement of the hyperfine splitting frequency of the ground state and the magnetic-field strength. Tuning the optical frequency difference to the central CPT resonance, a sensitivity of 15 p T / H z is achieved. The time response and the sensitivity of the CPT magnetometry are studied by changing the cell temperature, the laser power, the frequency separation of the light modes, and the Zeeman frequency.

Journal of the Optical Society of America B•Jun 7, 2021•4 citations

All-Optical Magnetometer Based on Resonant Excitation of Rubidium Atoms by Frequency Modulated Diode Laser Light

S. Cartaleva, Todor S. Karaulanov, Nikolay Petrov +6 more

Magnetic field and its gradient measurements based on coherent population trapping resonances at the D1 line of 87 Rb are performed by means of coupling two ground-state Zeeman sublevels belonging to different hyperfine levels to a common excited state.Two coherent laser fields with frequency difference of 6.8 GHz are used.They are produced by direct current modulation of a diode laser.The resonance splitting and broadening caused by the applied magnetic field is measured by scanning the laser modulation frequency around the ground-state hyperfine frequency.

Acta Physica Polonica A•Nov 1, 2007•2 citations

A remotely interrogated all-optical 87Rb magnetometer

Brian Patton, Oscar O. Versolato, D. C. Hovde +3 more

Atomic magnetometry was performed at Earth’s magnetic field over a free-space distance of ten meters. Two laser beams aimed at a distant alkali-vapor cell excited and detected the 87Rb magnetic resonance, allowing the magnetic field within the cell to be interrogated remotely. Operated as a driven oscillator, the magnetometer measured the geomagnetic field with ≲3.5 pT precision in a ∼2 s data acquisition; this precision was likely limited by ambient field fluctuations. The sensor was also operated in self-oscillating mode with a 5.3 pT/Hz noise floor. Further optimization will yield a high-bandwidth, fully remote magnetometer with sub-pT sensitivity.

arXiv:1208.1236•Applied Physics Letters•Aug 20, 2012•46 citations

Magnetometer and frequency standard based on coherently prepared thermal alkali atomic vapors

C. Affolderbach, W R G Kemp, Svenja A. Knappe +3 more

Summary form only given. We have experimentally investigated the potential of narrow coherent population trapping resonances for precision applications like magnetometry or atomic frequency standards. CPT can be observed in /spl Lambda/ systems where two ground states are coupled to a common excited state by two near-resonant light fields. Effective formation of ground state coherences takes place when the frequency difference of the light fields precisely matches the ground state splitting. This process leads to reduced absorption in the medium (electromagnetically induced transparency) and thus reduced fluorescence intensity (dark resonance) at the optical resonance frequency. Extremely narrow dark resonances can be observed when the two light fields have fixed phase and frequency difference and time-of-flight broadening is suppressed by the use of a buffer gas, making this type of system a promising candidate for precision applications. The /spl Lambda/ systems under study here are the D/sub 2/ lines of Cs, /sup 87/Rb and /sup 85/Rb where the ground state hyperfine splittings are 9.2 GHz, 6.8 GHz, and 3.0 GHz, respectively. Thus in a magnetic field the CPT resonance splits into several Zeeman components whose frequency positions are determined by the Breit-Rabi formula.

Quantum Electronics and Laser Science Conference•Jan 1, 2000•1 citation

Magnetic Field Measurement Using Peak-Locked Zeeman Coherent Population Trapping Resonance in Rubidium Vapor

Renu Tripathi, G. S. Pati

A sensor for magnetic field measurement is developed using a small (centimeter size) rubidium cell. A high contrast Zeeman coherent population trapping (CPT) resonance is produced by the magnetic dither in the sensor solenoid, and a peak-locked servo is implemented for magnetic field measurement. Sensitivity close to 110 pT/ √Hz has been achieved in axial field measurement. The CPT-based magnetic sensor is capable of measuring sub-nanotesla level magnetic field variations at high (microtesla) field strength. We discussed possible sources of noise and broadening which are affecting the performance of the sensor, and suggest changes that will further improve the performance of the sensor.

IEEE photonics journal•Jun 13, 2019•8 citations

Atomic magnetometer with microfabricated vapor cells based on coherent population trapping*

Xiaojie Li, Yuejiang Shi, Hongbo Xue +2 more

An atomic magnetometer based on coherent population trapping (CPT) resonances in microfabricated vapor cells is demonstrated. Fabricated by the micro-electro-mechanical-system (MEMS) technology, the cells are filled with Rb and Ne at a controlled pressure. An experimental apparatus is built for characterizing properties of microfabricated vapor cells via the CPT effects. The typical CPT linewidth is measured to be about 3 kHz (1.46 kHz with approximately zero laser intensity) for the rubidium D1 line at about 90 °C. The effects of pressure, temperature and laser intensity on CPT linewidth are studied experimentally. A closed-loop atomic magnetometer is finally finished with a sensitivity of 210.5 pT/Hz1/2 at 1 Hz bandwidth. This work paves the way for developing an integrated chip-scale atomic magnetometer in the future.

Chinese Physics B•Oct 20, 2020•8 citations
Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.
A glass lithium vapor cell is an atomic sensor operating at high temperature. The longitudinal magnetic-field strength is measured by coherent population trapping (CPT) in ground-state hyperfine levels. Two linearly polarized light beams are polarized orthogonally to each other. The difference of optical frequencies is tuned to generate a dark state. Additionally, a few light modes of equidistant frequency spacing are generated by modulating the difference frequency. The symmetry of the light modes and the energy levels enables simultaneous measurement of the hyperfine splitting frequency of the ground state and the magnetic-field strength. Tuning the optical frequency difference to the central CPT resonance, a sensitivity of 15 p T / H z is achieved. The time response and the sensitivity of the CPT magnetometry are studied by changing the cell temperature, the laser power, the frequency separation of the light modes, and the Zeeman frequency.
Magnetic field and its gradient measurements based on coherent population trapping resonances at the D1 line of 87 Rb are performed by means of coupling two ground-state Zeeman sublevels belonging to different hyperfine levels to a common excited state.Two coherent laser fields with frequency difference of 6.8 GHz are used.They are produced by direct current modulation of a diode laser.The resonance splitting and broadening caused by the applied magnetic field is measured by scanning the laser modulation frequency around the ground-state hyperfine frequency.
Atomic magnetometry was performed at Earth’s magnetic field over a free-space distance of ten meters. Two laser beams aimed at a distant alkali-vapor cell excited and detected the 87Rb magnetic resonance, allowing the magnetic field within the cell to be interrogated remotely. Operated as a driven oscillator, the magnetometer measured the geomagnetic field with ≲3.5 pT precision in a ∼2 s data acquisition; this precision was likely limited by ambient field fluctuations. The sensor was also operated in self-oscillating mode with a 5.3 pT/Hz noise floor. Further optimization will yield a high-bandwidth, fully remote magnetometer with sub-pT sensitivity.
Summary form only given. We have experimentally investigated the potential of narrow coherent population trapping resonances for precision applications like magnetometry or atomic frequency standards. CPT can be observed in /spl Lambda/ systems where two ground states are coupled to a common excited state by two near-resonant light fields. Effective formation of ground state coherences takes place when the frequency difference of the light fields precisely matches the ground state splitting. This process leads to reduced absorption in the medium (electromagnetically induced transparency) and thus reduced fluorescence intensity (dark resonance) at the optical resonance frequency. Extremely narrow dark resonances can be observed when the two light fields have fixed phase and frequency difference and time-of-flight broadening is suppressed by the use of a buffer gas, making this type of system a promising candidate for precision applications. The /spl Lambda/ systems under study here are the D/sub 2/ lines of Cs, /sup 87/Rb and /sup 85/Rb where the ground state hyperfine splittings are 9.2 GHz, 6.8 GHz, and 3.0 GHz, respectively. Thus in a magnetic field the CPT resonance splits into several Zeeman components whose frequency positions are determined by the Breit-Rabi formula.
A sensor for magnetic field measurement is developed using a small (centimeter size) rubidium cell. A high contrast Zeeman coherent population trapping (CPT) resonance is produced by the magnetic dither in the sensor solenoid, and a peak-locked servo is implemented for magnetic field measurement. Sensitivity close to 110 pT/ √Hz has been achieved in axial field measurement. The CPT-based magnetic sensor is capable of measuring sub-nanotesla level magnetic field variations at high (microtesla) field strength. We discussed possible sources of noise and broadening which are affecting the performance of the sensor, and suggest changes that will further improve the performance of the sensor.
An atomic magnetometer based on coherent population trapping (CPT) resonances in microfabricated vapor cells is demonstrated. Fabricated by the micro-electro-mechanical-system (MEMS) technology, the cells are filled with Rb and Ne at a controlled pressure. An experimental apparatus is built for characterizing properties of microfabricated vapor cells via the CPT effects. The typical CPT linewidth is measured to be about 3 kHz (1.46 kHz with approximately zero laser intensity) for the rubidium D1 line at about 90 °C. The effects of pressure, temperature and laser intensity on CPT linewidth are studied experimentally. A closed-loop atomic magnetometer is finally finished with a sensitivity of 210.5 pT/Hz1/2 at 1 Hz bandwidth. This work paves the way for developing an integrated chip-scale atomic magnetometer in the future.