Applied Optics

Loop-locked coherent population trapping magnetometer based on a fiber electro-optic modulator

Yong Hu, Y. Y. Feng, Chi Xu, Hongbo Xue, Li Quan Sun

Published Mar 27, 2014• 11 citations
Publisher

Abstract

We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.

DOI
10.1364/ao.53.002158

Related papers

All optical automated magnetic field monitoring based on coherent population trapping produced by a frequency-modulated diode laser

Jacopo Belfi, G. Bevilacqua, V. Biancalana +2 more

A fully automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) effect produced by a multi-frequency excitation. It has an all optical sensor connected only by an optical fiber to the laser head. This allows truly remote sensing and minimization of the field perturbation. The CPT resonance is observed when a frequency comb, generated by a diode laser current modulation, excites a sample of Cs atoms confined in a cell with 2 Torr of buffer gas. In differential sensor configuration, allowing for common-mode noise cancellation, the sensitivity of 45pT/square root of Hz is obtained.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Mar 2, 2007•0 citations

Atomic magnetometer with microfabricated vapor cells based on coherent population trapping*

Xiaojie Li, Yuejiang Shi, Hongbo Xue +2 more

An atomic magnetometer based on coherent population trapping (CPT) resonances in microfabricated vapor cells is demonstrated. Fabricated by the micro-electro-mechanical-system (MEMS) technology, the cells are filled with Rb and Ne at a controlled pressure. An experimental apparatus is built for characterizing properties of microfabricated vapor cells via the CPT effects. The typical CPT linewidth is measured to be about 3 kHz (1.46 kHz with approximately zero laser intensity) for the rubidium D1 line at about 90 °C. The effects of pressure, temperature and laser intensity on CPT linewidth are studied experimentally. A closed-loop atomic magnetometer is finally finished with a sensitivity of 210.5 pT/Hz1/2 at 1 Hz bandwidth. This work paves the way for developing an integrated chip-scale atomic magnetometer in the future.

Chinese Physics B•Oct 20, 2020•8 citations

All optical sensor for automated magnetometry based on coherent population trapping

Jacopo Belfi, G. Bevilacqua, V. Biancalana +2 more

An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on coherent population trapping (CPT) produced by a multifrequency excitation. CPT resonance is observed when a frequency comb, generated by diode laser current modulation, excites Cs atoms confined in a π/4×(2.5)2×1 cm3, 2 TorrN2 buffered cell. A fully optical sensor is connected through an optical fiber to the laser head allowing for truly remote sensing and minimization of the field perturbation. A detailed analysis of the CPT resonance parameters as a function of the optical detuning has been made in order to get high sensitivity measurements. The magnetic field monitoring performances and the best sensitivity obtained in a balanced differential configuration of the sensor are presented.

arXiv:0705.1671•Journal of the Optical Society of America B•Jun 15, 2007•36 citations

Coherent population trapping-based dual-wavelength modulation system for VCSEL

Jin Li, Dun Qian, Yifan Wang +2 more

Coherent Population Trapping (CPT)-based atomic magnetometers, as a prominent subclass of alkali-metal vapor-cell magnetometers, achieve ultrahigh magnetic-field sensitivity by exploiting an extremely narrow-linewidth optical resonance. A highly stable laser source is a fundamental prerequisite for realizing such performance. Conventionally, when a Vertical-Cavity Surface-Emitting Laser (VCSEL) is employed as the light source in CPT-based atomic magnetometers, its drive electronics rely on discrete benchtop instruments, resulting in bulky systems with limited flexibility and portability. In this work, we present a compact CPT-based dual-wavelength modulation system for the VCSEL. The design integrates a microwave signal generator with excellent phase-noise performance and a high-precision direct current signal source, enabling the generation of a significantly more stable bichromatic optical field. This highly integrated solution addresses the critical demand for robust, lownoise laser sources in a wide range of applications, including quantum sensing and precision measurement, quantum information and computation, as well as fundamental physics research.

International Conference on Computer Technology, Information Engineering, and Electron Materials (CTIEEM)•Apr 8, 2026•0 citations

Nonlinear Zeeman Effect Suppression for CPT Atom Magnetometers

Qiuchang Jia, Feifan Yang, Xianyang Huo +2 more

Geomagnetic measurement relies on high-sensitivity sensors, where coherent population trapping (CPT) magnetometers show promise due to advantages such as no dead zone and miniaturization capability. However, their sensitivity in geomagnetic environments is limited by the nonlinear Zeeman effect. This article establishes a magnetic field measurement model that suppresses this effect by utilizing the linear relationship between the external magnetic field and the frequency difference of the two peaks resulting from the resplitting of the zeroth-order CPT resonance. Theoretical analysis confirms that, at geomagnetic field strength, the frequency difference maintains a strict linear proportionality of 55.713 kHz/mT, whereas traditional methods fail due to higher order energy shifts. To enhance the weak CPT resonance, a closed-loop control system based on spontaneous fluorescence feedback was implemented, stabilizing the excited-state population via real-time laser power adjustment. Experimental results show that under closed-loop operation, the CPT signal amplitude increases approximately threefold with no significant linewidth broadening, theoretically improving sensitivity by 1.1 times, and the resplit double-peak structure is clearly observed in a geomagnetic environment. This approach provides a viable strategy for improving the sensitivity and accuracy of CPT magnetometers in geomagnetic field measurements.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

Quantum vector magnetometer based on the CPT effect in 87Rb vapour

Valeriy Andryushkov, Daba A. Radnatarov, Sergey M Kobtsev +1 more

Developed and characterised for the first time is a quantum vector magnetometer using coherent population trapping (CPT) in 87Rb vapour and external magnetic field compensation by 3-axis Helmholtz coils to stabilize the amplitude and spectral position of the CPT resonance excited on a magneto-sensitive (mf ≠ 0) energy level transition. To measure the magnetic field components orthogonal to the magnetometer optical axis, resonance amplitude dependence upon the transverse field strength is used, which has a maximum at zero transverse field. The proposed approach allowed measurement of the external magnetic field vector with a sensitivity exceeding 500 pT/Hz1/2.

•Aug 22, 2020•2 citations
We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.
A fully automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on Coherent Population Trapping (CPT) effect produced by a multi-frequency excitation. It has an all optical sensor connected only by an optical fiber to the laser head. This allows truly remote sensing and minimization of the field perturbation. The CPT resonance is observed when a frequency comb, generated by a diode laser current modulation, excites a sample of Cs atoms confined in a cell with 2 Torr of buffer gas. In differential sensor configuration, allowing for common-mode noise cancellation, the sensitivity of 45pT/square root of Hz is obtained.
An atomic magnetometer based on coherent population trapping (CPT) resonances in microfabricated vapor cells is demonstrated. Fabricated by the micro-electro-mechanical-system (MEMS) technology, the cells are filled with Rb and Ne at a controlled pressure. An experimental apparatus is built for characterizing properties of microfabricated vapor cells via the CPT effects. The typical CPT linewidth is measured to be about 3 kHz (1.46 kHz with approximately zero laser intensity) for the rubidium D1 line at about 90 °C. The effects of pressure, temperature and laser intensity on CPT linewidth are studied experimentally. A closed-loop atomic magnetometer is finally finished with a sensitivity of 210.5 pT/Hz1/2 at 1 Hz bandwidth. This work paves the way for developing an integrated chip-scale atomic magnetometer in the future.
An automated magnetometer suitable for long lasting measurement under stable and controllable experimental conditions has been implemented. The device is based on coherent population trapping (CPT) produced by a multifrequency excitation. CPT resonance is observed when a frequency comb, generated by diode laser current modulation, excites Cs atoms confined in a π/4×(2.5)2×1 cm3, 2 TorrN2 buffered cell. A fully optical sensor is connected through an optical fiber to the laser head allowing for truly remote sensing and minimization of the field perturbation. A detailed analysis of the CPT resonance parameters as a function of the optical detuning has been made in order to get high sensitivity measurements. The magnetic field monitoring performances and the best sensitivity obtained in a balanced differential configuration of the sensor are presented.
Coherent Population Trapping (CPT)-based atomic magnetometers, as a prominent subclass of alkali-metal vapor-cell magnetometers, achieve ultrahigh magnetic-field sensitivity by exploiting an extremely narrow-linewidth optical resonance. A highly stable laser source is a fundamental prerequisite for realizing such performance. Conventionally, when a Vertical-Cavity Surface-Emitting Laser (VCSEL) is employed as the light source in CPT-based atomic magnetometers, its drive electronics rely on discrete benchtop instruments, resulting in bulky systems with limited flexibility and portability. In this work, we present a compact CPT-based dual-wavelength modulation system for the VCSEL. The design integrates a microwave signal generator with excellent phase-noise performance and a high-precision direct current signal source, enabling the generation of a significantly more stable bichromatic optical field. This highly integrated solution addresses the critical demand for robust, lownoise laser sources in a wide range of applications, including quantum sensing and precision measurement, quantum information and computation, as well as fundamental physics research.
Geomagnetic measurement relies on high-sensitivity sensors, where coherent population trapping (CPT) magnetometers show promise due to advantages such as no dead zone and miniaturization capability. However, their sensitivity in geomagnetic environments is limited by the nonlinear Zeeman effect. This article establishes a magnetic field measurement model that suppresses this effect by utilizing the linear relationship between the external magnetic field and the frequency difference of the two peaks resulting from the resplitting of the zeroth-order CPT resonance. Theoretical analysis confirms that, at geomagnetic field strength, the frequency difference maintains a strict linear proportionality of 55.713 kHz/mT, whereas traditional methods fail due to higher order energy shifts. To enhance the weak CPT resonance, a closed-loop control system based on spontaneous fluorescence feedback was implemented, stabilizing the excited-state population via real-time laser power adjustment. Experimental results show that under closed-loop operation, the CPT signal amplitude increases approximately threefold with no significant linewidth broadening, theoretically improving sensitivity by 1.1 times, and the resplit double-peak structure is clearly observed in a geomagnetic environment. This approach provides a viable strategy for improving the sensitivity and accuracy of CPT magnetometers in geomagnetic field measurements.
Developed and characterised for the first time is a quantum vector magnetometer using coherent population trapping (CPT) in 87Rb vapour and external magnetic field compensation by 3-axis Helmholtz coils to stabilize the amplitude and spectral position of the CPT resonance excited on a magneto-sensitive (mf ≠ 0) energy level transition. To measure the magnetic field components orthogonal to the magnetometer optical axis, resonance amplitude dependence upon the transverse field strength is used, which has a maximum at zero transverse field. The proposed approach allowed measurement of the external magnetic field vector with a sensitivity exceeding 500 pT/Hz1/2.