IEEE photonics journal

Magnetic Field Measurement Using Peak-Locked Zeeman Coherent Population Trapping Resonance in Rubidium Vapor

Renu Tripathi, G. S. Pati

Published Jun 13, 2019• 8 citations
Publisher

Abstract

A sensor for magnetic field measurement is developed using a small (centimeter size) rubidium cell. A high contrast Zeeman coherent population trapping (CPT) resonance is produced by the magnetic dither in the sensor solenoid, and a peak-locked servo is implemented for magnetic field measurement. Sensitivity close to 110 pT/ √Hz has been achieved in axial field measurement. The CPT-based magnetic sensor is capable of measuring sub-nanotesla level magnetic field variations at high (microtesla) field strength. We discussed possible sources of noise and broadening which are affecting the performance of the sensor, and suggest changes that will further improve the performance of the sensor.

DOI
10.1109/jphot.2019.2922831

Related papers

Demonstration of a field-deployable vector magnetometer using synchronous coherent population trapping and feedback compensation mechanism

Renu Tripathi, G. S. Pati, Mauricio Pulido

We have developed a field-deployable vector magnetometer using a small rubidium vapor cell, which is capable of measuring the magnitude and direction of the earth's magnetic field with high accuracy and sensitivity. The magnetometer measures Larmor precession of rubidium atoms using the phenomenon, called synchronous coherent population trapping (SCPT). This gives the advantage of producing a high contrast and narrow linewidth resonance needed for measuring the magnetic field with high accuracy and sensitivity. The magnetometer exhibits sub-nT/√Hz sensitivities in measuring the field components along the three directions.

SPIE Quantum Information Science, Sensing, and Computation•Jun 7, 2024•0 citations

Single-shot vector magnetic measurements using synchronous coherent population trapping resonance in a feedback compensation system

G. S. Pati, Renu Tripathi, Mauricio Pulido

We demonstrate a real-time, single-shot vector magnetic measurement technique using synchronous coherent population trapping (SCPT) in an apparatus consisting of a small rubidium vapor cell. Vector modality of our magnetometer is enabled by designing a feedback system based on performing a peak-lock on a particularly strong 2ΩL magnetic resonance produced in the SCPT spectrum and compensating the external magnetic field via a three-axis field coil. With its current design, this magnetometer exhibits high sensitivities of approximately 155, 129, and 57pT/Hz in measuring the magnetic field vector components along the (x,y,z) axes. Sensitivities closer to the shot-noise limit can be achieved in the future by reducing the technical noise of our equipment and by employing a differential detection and polarization rotation measurement scheme in our system.

Journal of Applied Physics•Nov 10, 2023•5 citations

Remotely-sensed atomic magnetometry

Christopher J. Sataline

Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.

•Jan 1, 2013•0 citations

Nonlinear Zeeman Effect Suppression for CPT Atom Magnetometers

Qiuchang Jia, Feifan Yang, Xianyang Huo +2 more

Geomagnetic measurement relies on high-sensitivity sensors, where coherent population trapping (CPT) magnetometers show promise due to advantages such as no dead zone and miniaturization capability. However, their sensitivity in geomagnetic environments is limited by the nonlinear Zeeman effect. This article establishes a magnetic field measurement model that suppresses this effect by utilizing the linear relationship between the external magnetic field and the frequency difference of the two peaks resulting from the resplitting of the zeroth-order CPT resonance. Theoretical analysis confirms that, at geomagnetic field strength, the frequency difference maintains a strict linear proportionality of 55.713 kHz/mT, whereas traditional methods fail due to higher order energy shifts. To enhance the weak CPT resonance, a closed-loop control system based on spontaneous fluorescence feedback was implemented, stabilizing the excited-state population via real-time laser power adjustment. Experimental results show that under closed-loop operation, the CPT signal amplitude increases approximately threefold with no significant linewidth broadening, theoretically improving sensitivity by 1.1 times, and the resplit double-peak structure is clearly observed in a geomagnetic environment. This approach provides a viable strategy for improving the sensitivity and accuracy of CPT magnetometers in geomagnetic field measurements.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

Loop-locked coherent population trapping magnetometer based on a fiber electro-optic modulator

Yong Hu, Y. Y. Feng, Chi Xu +2 more

We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.

Applied Optics•Mar 27, 2014•11 citations

Design and development of a field-deployable vector magnetometer prototype

Renu Tripathi, G. S. Pati, Mauricio Pulido

Vector magnetic field measurement is required in several applications including magnetic surveys, navigation and anomalies detection. We have designed and developed a vector magnetometer prototype that can be deployed in the field to survey earth’s magnetic field. Vector operation is enabled in this prototype by using the phenomenon of synchronous coherent population trapping (SCPT), and combining it with a feedback compensation mechanism. The prototype utilizes a small rubidium cell which is placed inside a three-axis field coil. Magnetic field along each axis is measured by performing a peak-lock on one of the strongest resonances produced by SCPT and compensating the external magnetic field via servo control of the three-axis field coil. Under this locked condition, the feedback current applied to each coil in the three-axis system gives a real-time, single-shot measurement of the magnetic field components. Extensive testing of the prototype is being done by performing magnetic field measurements in the magnetically noisy environment inside the laboratory and in-comparison with that of a fluxgate sensor.

Optical and Quantum Sensing and Precision Metrology II•Mar 19, 2025•0 citations
A sensor for magnetic field measurement is developed using a small (centimeter size) rubidium cell. A high contrast Zeeman coherent population trapping (CPT) resonance is produced by the magnetic dither in the sensor solenoid, and a peak-locked servo is implemented for magnetic field measurement. Sensitivity close to 110 pT/ √Hz has been achieved in axial field measurement. The CPT-based magnetic sensor is capable of measuring sub-nanotesla level magnetic field variations at high (microtesla) field strength. We discussed possible sources of noise and broadening which are affecting the performance of the sensor, and suggest changes that will further improve the performance of the sensor.
We have developed a field-deployable vector magnetometer using a small rubidium vapor cell, which is capable of measuring the magnitude and direction of the earth's magnetic field with high accuracy and sensitivity. The magnetometer measures Larmor precession of rubidium atoms using the phenomenon, called synchronous coherent population trapping (SCPT). This gives the advantage of producing a high contrast and narrow linewidth resonance needed for measuring the magnetic field with high accuracy and sensitivity. The magnetometer exhibits sub-nT/√Hz sensitivities in measuring the field components along the three directions.
We demonstrate a real-time, single-shot vector magnetic measurement technique using synchronous coherent population trapping (SCPT) in an apparatus consisting of a small rubidium vapor cell. Vector modality of our magnetometer is enabled by designing a feedback system based on performing a peak-lock on a particularly strong 2ΩL magnetic resonance produced in the SCPT spectrum and compensating the external magnetic field via a three-axis field coil. With its current design, this magnetometer exhibits high sensitivities of approximately 155, 129, and 57pT/Hz in measuring the magnetic field vector components along the (x,y,z) axes. Sensitivities closer to the shot-noise limit can be achieved in the future by reducing the technical noise of our equipment and by employing a differential detection and polarization rotation measurement scheme in our system.
Coherent population trapping (CPT) effects can be realized with frequency mod- ulated lasers and compact vapor cells of alkali metals such as Rubidium-87. Using these optical resonances, one can readily measure the hyperfine separation of this three-level atom. In the presence of a magnetic field, the Zeeman effect causes magnetic sublevels of these hyperfine ground states to split; the frequency of such splitting can be measured in an ensemble of Rubidium atoms with the magnetometer we have constructed. While other groups have constructed magnetometers based on these effects, none to our knowledge have investigated the capability to measure magnetic fields remotely. Most atomic-optical magnetometers,colocate the transmit and receive optical system with the vapor cell itself or require fiber optics at the location of the cell; our free-space technique with a reflective geometry lends itself to measurement at distances greater than could be achieved with those methods. We have developed a laboratory FM laser spectrometer that interrogates CPT resonances to measure magnetic fields with the vapor cell not necessarily co-located with the spectrometer. Its intrinsic linewidth (in the presence of transit-time broadening) is less than 30 kilohertz, which allows measurements on the order of 2 microtesla. We present results concerning the accuracy of the magnetometer at about one meter of standoff distance, and describe considerations for measurements at longer distances.
Geomagnetic measurement relies on high-sensitivity sensors, where coherent population trapping (CPT) magnetometers show promise due to advantages such as no dead zone and miniaturization capability. However, their sensitivity in geomagnetic environments is limited by the nonlinear Zeeman effect. This article establishes a magnetic field measurement model that suppresses this effect by utilizing the linear relationship between the external magnetic field and the frequency difference of the two peaks resulting from the resplitting of the zeroth-order CPT resonance. Theoretical analysis confirms that, at geomagnetic field strength, the frequency difference maintains a strict linear proportionality of 55.713 kHz/mT, whereas traditional methods fail due to higher order energy shifts. To enhance the weak CPT resonance, a closed-loop control system based on spontaneous fluorescence feedback was implemented, stabilizing the excited-state population via real-time laser power adjustment. Experimental results show that under closed-loop operation, the CPT signal amplitude increases approximately threefold with no significant linewidth broadening, theoretically improving sensitivity by 1.1 times, and the resplit double-peak structure is clearly observed in a geomagnetic environment. This approach provides a viable strategy for improving the sensitivity and accuracy of CPT magnetometers in geomagnetic field measurements.
We have set up a coherent population trapping (CPT)-based magnetometer prototype with the D1 line of ⁸⁷Rb atoms. The dichromatic light field is derived from a fiber electro-optic modulator (FEOM) connected to an external cavity laser diode. A CPT resonance signal with a 516 Hz linewidth is observed. By feeding back the derivative of the resonance curve to the FEOM with a proportional integral controller, of which the voltage output is directly converted to the measured magnetic field intensity, the resonance peak is locked to the environmental magnetic field. The measurement data we have achieved are well matched with the data measured by a commercial fluxgate magnetometer within 2 nT, and the sensitivity is better than 8 pT/√Hz in a parallel B field.
Vector magnetic field measurement is required in several applications including magnetic surveys, navigation and anomalies detection. We have designed and developed a vector magnetometer prototype that can be deployed in the field to survey earth’s magnetic field. Vector operation is enabled in this prototype by using the phenomenon of synchronous coherent population trapping (SCPT), and combining it with a feedback compensation mechanism. The prototype utilizes a small rubidium cell which is placed inside a three-axis field coil. Magnetic field along each axis is measured by performing a peak-lock on one of the strongest resonances produced by SCPT and compensating the external magnetic field via servo control of the three-axis field coil. Under this locked condition, the feedback current applied to each coil in the three-axis system gives a real-time, single-shot measurement of the magnetic field components. Extensive testing of the prototype is being done by performing magnetic field measurements in the magnetically noisy environment inside the laboratory and in-comparison with that of a fluxgate sensor.