Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:quant-ph/0404090 · Journal of Physics A Mathematical and General

Operational formulation of homodyne detection

Tomá Tyc, Barry C. Sanders

Published Jul 8, 2004• 53 citations
arXivHTMLPDF

Abstract

We obtain the standard quadrature-phase positive operator-valued measure (POVM) for homodyne detection directly and rigorously from the POVM for photon counting without directly employing the mean field approximation for the local oscillator. In addition, we obtain correction terms for the quadrature-phase POVM that are applicable for relatively weak local oscillator field strengths and typical signal states.

DOI
10.1088/0305-4470/37/29/010

Related papers

Homodyne-like detection scheme based on photon-number-resolving detectors

Alessia Allevi, Matteo Bina, Stefano Olivares +1 more

Homodyne detection is the most effective detection scheme employed in quantum optics to characterize quantum states. It is based on mixing at a beam splitter the signal to be measured with a coherent state, called the “local oscillator,” and on evaluating the difference of the photocurrents of two photodiodes measuring the outputs of the beam splitter. If the local oscillator is much more intense than the field to be measured, the homodyne signal is proportional to the signal-field quadratures. If the local oscillator is less intense, the photodiodes can be replaced with photon-number-resolving detectors, which have a smaller dynamics but can measure the light statistics. The resulting new homodyne-like detector acquires a hybrid nature, being it capable of yielding information on both the particle-like (statistics) and wave-like (phase) properties of light signals. The scheme has been tested in the measurement of the quadratures of coherent states, bracket states and phase-averaged coherent states at different intensities of the local oscillator.

International Journal of Quantum Information•Dec 1, 2017•14 citations

Statistics of difference events in homodyne detection

W. Vogel, Jens Grabow

The statistics of the difference events in a balanced homodyne-detection scheme is studied without using the standard assumption of a strong, classical local oscillator. Starting from the quantum theory of photon counting, we derive the probability distribution for the difference events in the two detection channels. In the limit of the local oscillator being strong compared with the signal, the difference-number statistics tends to the statistics of the electric-field strength of the signal field. For weak signals, this limit may be obtained already far from a classical behavior of the local oscillator. While changing the local oscillator intensity, a transition of the observable concerning the signal field occurs from the photon-number difference towards the electric-field strength. Such a measurement scheme renders it possible to observe the quantum features of a coherent state or a single-photon state from the point of view of the field-strength statistics, a picture which is closely related to classical optics. The possibility to get some insight in the statistical properties of the phase difference of two microscopic fields is discussed.

Physical Review A•May 1, 1993•89 citations

Operational theory of homodyne detection

Konrad Banaszek, Krzysztof Wódkiewicz

We discuss a balanced homodyne detection scheme with imperfect detectors in the framework of the operational approach to quantum measurement. We show that a realistic homodyne measurement is described by a family of operational observables that depends on the experimental setup, rather than a single field quadrature operator. We find an explicit form of this family, which fully characterizes the experimental device and is independent of a specific state of the measured system. We also derive operational homodyne observables for the setup with a random phase, which has been recently applied in an ultrafast measurement of the photon statistics of a pulsed diode laser. The operational formulation directly gives the relation between the detected noise and the intrinsic quantum fluctuations of the measured field. We demonstrate this with two examples: the operational uncertainty relation for the field quadratures, and the homodyne detection of suppressed fluctuations in photon statistics.

arXiv:atom-ph/9609001•Physical Review A•Apr 1, 1997•68 citations

Measurement of the Polarization State of a Weak Signal Field by Homodyne Detection

Sun-Hyun Youn

Information carried by an optical beam of light can usually be conveyed in the form of a temporal modulation of the intensity, phase, frequency or the polarization of the constituent mode(s). In that regard, homodyne detection is one of the most popular and standard method to measure the quantum mechanical properties of light Yuen & Shapiro (1978); Yuen et al. (1979); Yuen & Shapiro (1980); Yurke (1985). The quantum theory of homodyne detection originated principally from the works of Yuen and Shapiro et al. Yuen & Shapiro (1978); Yuen et al. (1979). In this method, a weak signal field is combined with a strong local oscillator field at a beam splitter, and the resulting signal is measured as a photocurrent. With the homodyne detection method, the quantum state of the signal field, such as the quadrature amplitude of the squeezed state, is easily measured Slusher et al. (1985); Wu et al. (1986 ); Polzik et al. (1992), and the quasiprobability distribution function can be measured by using the so-called optical homodyne tomography Smithey et al. (1993); Banaszek & W’odkiewicz (1996); Wallentowitz & Vogel (1996); Youn et al. (2001). Furthermore, optical homodyne detection is used to eavesdrop on the quantum key in quantum cryptography Hirano et al. (2000).

InTech eBooks•Mar 23, 2012•2 citations

Quantum retrodiction in Gaussian systems and applications in optomechanics

Jonas Lammers, Klemens Hammerer

What knowledge can be obtained from the record of a continuous measurement about the quantum state of the measured system at the beginning of the measurement? The task of quantum state retrodiction, the inverse of the more common state prediction, is rigorously addressed in quantum measurement theory through retrodictive positive operator-valued measures (POVMs). This introduction to this general framework presents its practical formulation for retrodicting Gaussian quantum states using continuous-time homodyne measurements and applies it to optomechanical systems. We identify and characterize achievable retrodictive POVMs in common optomechanical operating modes with resonant or off-resonant driving fields and specific choices of local oscillator frequencies in homodyne detection. In particular, we demonstrate the possibility of a near-ideal measurement of the quadrature of the mechanical oscillator, giving direct access to the position or momentum distribution of the oscillator at a given time. This forms the basis for complete quantum state tomography, albeit in a destructive manner.

arXiv:2309.03507•Frontiers in Quantum Science and Technology•Jan 25, 2024•6 citations

Noise in homodyne detection

Bonny L. Schumaker

A simple but rigorous analysis of the important sources of noise in homodyne detection is presented. Output noise and signal-to-noise ratios are compared for direct detection, conventional (one-port) homodyning, and two-port homodyning, in which one monitors both output ports of a 50-50 beam splitter. It is shown that two-port homodyning is insensitive to local-oscillator quadrature-phase noise and hence provides (1) a means of detecting reduced quadrature-phase fluctuations (squeezing) that is perhaps more practical than one-port homodyning and (2) an output signal-to-noise ratio that can be a modest to significant improvement over that of one-port homodyning and direct detection.

Optics Letters•May 1, 1984•244 citations
We obtain the standard quadrature-phase positive operator-valued measure (POVM) for homodyne detection directly and rigorously from the POVM for photon counting without directly employing the mean field approximation for the local oscillator. In addition, we obtain correction terms for the quadrature-phase POVM that are applicable for relatively weak local oscillator field strengths and typical signal states.
Homodyne detection is the most effective detection scheme employed in quantum optics to characterize quantum states. It is based on mixing at a beam splitter the signal to be measured with a coherent state, called the “local oscillator,” and on evaluating the difference of the photocurrents of two photodiodes measuring the outputs of the beam splitter. If the local oscillator is much more intense than the field to be measured, the homodyne signal is proportional to the signal-field quadratures. If the local oscillator is less intense, the photodiodes can be replaced with photon-number-resolving detectors, which have a smaller dynamics but can measure the light statistics. The resulting new homodyne-like detector acquires a hybrid nature, being it capable of yielding information on both the particle-like (statistics) and wave-like (phase) properties of light signals. The scheme has been tested in the measurement of the quadratures of coherent states, bracket states and phase-averaged coherent states at different intensities of the local oscillator.
The statistics of the difference events in a balanced homodyne-detection scheme is studied without using the standard assumption of a strong, classical local oscillator. Starting from the quantum theory of photon counting, we derive the probability distribution for the difference events in the two detection channels. In the limit of the local oscillator being strong compared with the signal, the difference-number statistics tends to the statistics of the electric-field strength of the signal field. For weak signals, this limit may be obtained already far from a classical behavior of the local oscillator. While changing the local oscillator intensity, a transition of the observable concerning the signal field occurs from the photon-number difference towards the electric-field strength. Such a measurement scheme renders it possible to observe the quantum features of a coherent state or a single-photon state from the point of view of the field-strength statistics, a picture which is closely related to classical optics. The possibility to get some insight in the statistical properties of the phase difference of two microscopic fields is discussed.
We discuss a balanced homodyne detection scheme with imperfect detectors in the framework of the operational approach to quantum measurement. We show that a realistic homodyne measurement is described by a family of operational observables that depends on the experimental setup, rather than a single field quadrature operator. We find an explicit form of this family, which fully characterizes the experimental device and is independent of a specific state of the measured system. We also derive operational homodyne observables for the setup with a random phase, which has been recently applied in an ultrafast measurement of the photon statistics of a pulsed diode laser. The operational formulation directly gives the relation between the detected noise and the intrinsic quantum fluctuations of the measured field. We demonstrate this with two examples: the operational uncertainty relation for the field quadratures, and the homodyne detection of suppressed fluctuations in photon statistics.
Information carried by an optical beam of light can usually be conveyed in the form of a temporal modulation of the intensity, phase, frequency or the polarization of the constituent mode(s). In that regard, homodyne detection is one of the most popular and standard method to measure the quantum mechanical properties of light Yuen & Shapiro (1978); Yuen et al. (1979); Yuen & Shapiro (1980); Yurke (1985). The quantum theory of homodyne detection originated principally from the works of Yuen and Shapiro et al. Yuen & Shapiro (1978); Yuen et al. (1979). In this method, a weak signal field is combined with a strong local oscillator field at a beam splitter, and the resulting signal is measured as a photocurrent. With the homodyne detection method, the quantum state of the signal field, such as the quadrature amplitude of the squeezed state, is easily measured Slusher et al. (1985); Wu et al. (1986 ); Polzik et al. (1992), and the quasiprobability distribution function can be measured by using the so-called optical homodyne tomography Smithey et al. (1993); Banaszek & W’odkiewicz (1996); Wallentowitz & Vogel (1996); Youn et al. (2001). Furthermore, optical homodyne detection is used to eavesdrop on the quantum key in quantum cryptography Hirano et al. (2000).
What knowledge can be obtained from the record of a continuous measurement about the quantum state of the measured system at the beginning of the measurement? The task of quantum state retrodiction, the inverse of the more common state prediction, is rigorously addressed in quantum measurement theory through retrodictive positive operator-valued measures (POVMs). This introduction to this general framework presents its practical formulation for retrodicting Gaussian quantum states using continuous-time homodyne measurements and applies it to optomechanical systems. We identify and characterize achievable retrodictive POVMs in common optomechanical operating modes with resonant or off-resonant driving fields and specific choices of local oscillator frequencies in homodyne detection. In particular, we demonstrate the possibility of a near-ideal measurement of the quadrature of the mechanical oscillator, giving direct access to the position or momentum distribution of the oscillator at a given time. This forms the basis for complete quantum state tomography, albeit in a destructive manner.
A simple but rigorous analysis of the important sources of noise in homodyne detection is presented. Output noise and signal-to-noise ratios are compared for direct detection, conventional (one-port) homodyning, and two-port homodyning, in which one monitors both output ports of a 50-50 beam splitter. It is shown that two-port homodyning is insensitive to local-oscillator quadrature-phase noise and hence provides (1) a means of detecting reduced quadrature-phase fluctuations (squeezing) that is perhaps more practical than one-port homodyning and (2) an output signal-to-noise ratio that can be a modest to significant improvement over that of one-port homodyning and direct detection.