Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Direct observation of a single proton in a Penning trap. Towards a direct measurement of the proton g-factor

S. Kreim

Published Jun 29, 2009• 0 citations
OpenAlex

Abstract

This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i. e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10−7. The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range.

Related papers

Direct Measurement of the Free Cyclotron Frequency of a Single Particle in a Penning Trap

S. Ulmer, K. Blaum, Holger Kracke +4 more

A measurement scheme for the direct determination of the free cyclotron frequency ν(c) of a single particle stored in a Penning trap is described. The method is based on the dressed states of mode coupling. In this novel measurement scheme both radial modes of the single trapped particle are simultaneously coupled to the axial oscillation mode.

Physical Review Letters•Sep 1, 2011•23 citations

Detection Electronics Design and First Observation of Bound-Electron Spin Transitions at the ALPHATRAP g-Factor Experiment

Weigel, Andreas

ALPHATRAP is a Penning-trap based experiment located at the Max-Planck-Institut für Kernphysik (MPIK). It is dedicated to the exploration of ground-state properties of heavy, highly charged ions (HCI). The major goal of the ALPHATRAP \nexperiment are high precision measurements of the bound-electron g-factor. The comparison of the experimental result with recent theoretical calculations will not only serve as a sensitive test of bound-state quantum electrodynamics (BS-QED) but also yields a new approach for the determination of fundamental constants such as the electron mass or the fine structure constant. The measurement of the bound-electron g-factor of a single HCI is performed in an optimized cryogenic double Penning-trap setup, utilizing the continuous Stern-Gerlach effect. For injection of externally produced HCI up to 208Pb81+ the ALPHATRAP experiment is \ncoupled to various ion sources, including the Heidelberg Electron-Beam Ion Trap. \nThis thesis describes the setup and preparation of the ALPHATRAP experiment on its way towards its first g-factor measurement. In this context a new highly sensitive detection system was implemented and successfully tested. This enabled a first commissioning of the whole apparatus with in situ generated HCI as well as HCI injected through the room temperature beamline. The first-time integration \nof an externally operable cryogenic valve allowed for excellent vacuum conditions with long ion storage times. The implementation of typical ion detection and manipulation techniques was demonstrated by characterization measurements of the detection system and the trapping fields. The commissioning culminated in the first direct observation of induced bound-electron spin transitions at the \nALPHATRAP experiment.

Ruprecht-Karls-Universität Heidelberg eBooks•Jan 1, 2019•1 citation

Cavity control in a single-electron quantum cyclotron

David Hanneke

A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.

•Jan 1, 2007•0 citations

Resolution of Single Spin Flips of a Single Proton

Andreas H. Mooser, Holger Kracke, K. Blaum +7 more

The spin magnetic moment of a single proton in a cryogenic Penning trap was coupled to the particle's axial motion with a superimposed magnetic bottle. Jumps in the oscillation frequency indicate spin flips and were identified using a Bayesian analysis.

arXiv:1303.1359•Physical Review Letters•Apr 4, 2013•54 citations

Full Single-Quantum Control of Particles in Penning Traps for Symmetry Tests at the Quantum Limit

J. M. Cornejo, J. -A. Coenders, A. Lissel +9 more

The BASE collaboration aims to measure antimatter systems with the highest precision in order to perform a rigorous test of CPT symmetry and search for physics beyond the Standard Model. As part of the BASE collaboration, we pursue the development of quantum logic inspired cooling and detection techniques for g-factor measurements of (anti-)protons. Implementing these methods requires full quantum-level control of individual antimatter particles confined in cryogenic Penning traps. By mapping the (anti-)proton's internal state onto a co-trapped 9Be+ "logic" ion via free Coulomb coupling in a double-well potential, we can accelerate measurement cycles and push g-factor precision measurements on (anti-)protons toward the quantum limit. Here, we present an overview of the proposed method and the current status of the project, with special emphasis on the new cryogenic multi-Penning-trap stack and the proton detection system.

physics.atom-phCross-listedarXiv:2602.22802•Feb 27, 2026

The Geonium Chip: engineering a scalable planar Penningtrap

Jonathan Pinder

In this thesis is presented the realisation of `The Geonium Chip', a novel planar Penning trap. The chip is designed with the goal of building a truly scalable planar Penning trap, while retaining the accuracy of 3D traps. Manufactured with conventional metalon- silicon microfabrication techniques, the chip takes the 5 electrodes of the compensated cylindrical trap and projects them onto a ground-plane surface, thus forming the basis for its layout by reducing the electrode shape to an array of at rectangular surfaces. In this thesis I describe the conception, design and construction of a full cryogenic set-up, including the magnetics, for trapping and observing a single electron in the Geonium Chip Penning trap. The cyclotron mode of the trapped electron lies in the microwave regime, and thus the Geonium Chip has the potential to become a powerful building block for quantum microwave circuits, with coherent coupling to the cyclotron degree of freedom. This will also allow non-destructive measurement and interaction with the spin state of the electron. The development of the experimental process is detailed from scratch including the design, fabrication, and testing of the Geonium Chip, as well as the design, fabrication and testing of the experimental apparatus. The original solutions and space saving designs developed as part of the construction process are detailed, such as the custom on-chip cryogenic vacuum chamber, planar magnetic field source, and the LED-based electron loading system. The vacuum chamber and control systems are also described, and the in-house manufacturing capabilities of the Geonium group are detailed at length, with an emphasis on rapid prototyping high-accuracy components suitable for experimental use. The apparatus built within this PhD is within a few weeks of performing the first loading of electrons into the chip trap.

•Feb 21, 2017•4 citations
This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i. e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10−7. The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range.
ALPHATRAP is a Penning-trap based experiment located at the Max-Planck-Institut für Kernphysik (MPIK). It is dedicated to the exploration of ground-state properties of heavy, highly charged ions (HCI). The major goal of the ALPHATRAP \nexperiment are high precision measurements of the bound-electron g-factor. The comparison of the experimental result with recent theoretical calculations will not only serve as a sensitive test of bound-state quantum electrodynamics (BS-QED) but also yields a new approach for the determination of fundamental constants such as the electron mass or the fine structure constant. The measurement of the bound-electron g-factor of a single HCI is performed in an optimized cryogenic double Penning-trap setup, utilizing the continuous Stern-Gerlach effect. For injection of externally produced HCI up to 208Pb81+ the ALPHATRAP experiment is \ncoupled to various ion sources, including the Heidelberg Electron-Beam Ion Trap. \nThis thesis describes the setup and preparation of the ALPHATRAP experiment on its way towards its first g-factor measurement. In this context a new highly sensitive detection system was implemented and successfully tested. This enabled a first commissioning of the whole apparatus with in situ generated HCI as well as HCI injected through the room temperature beamline. The first-time integration \nof an externally operable cryogenic valve allowed for excellent vacuum conditions with long ion storage times. The implementation of typical ion detection and manipulation techniques was demonstrated by characterization measurements of the detection system and the trapping fields. The commissioning culminated in the first direct observation of induced bound-electron spin transitions at the \nALPHATRAP experiment.
A single electron in a quantum cyclotron yields new measurements of the electron magnetic moment, given by g/2 = 1.00115965218073(28)[0.28 ppt], and the fine structure constant, α −1 = 137.035999084(51)[0.37 ppb], both significantly improved from prior results. The static magnetic and electric fields of a Penning trap confine the electron, and a 100 mK dilution refrigerator cools its cyclotron motion to the quantum-mechanical ground state. A quantum nondemolition measurement allows resolution of single cyclotron jumps and spin flips by coupling the cyclotron and spin energies to the frequency of the axial motion, which is self-excited and detected with a cryogenic amplifier. The trap electrodes form a high-Q microwave resonator near the cyclotron frequency; coupling between the cyclotron motion and cavity modes can inhibit spontaneous emission by over 100 timesthe free-space rate and shiftthe cyclotron frequency, a systematic effect that dominated the uncertainties of previous g-value measurements. A cylindrical trap geometry creates cavity modes with analytically calculable couplingsto cyclotron motion. Two independent methods use the cyclotron damping rate of an electron plasma or of the single electron itself as probes of the cavity mode structure and allow the identification ofthe modes by their geometries and couplings, the quantification of an offset between the mode and electrostatic centers, and the reduction of the cavity shift uncertainty to sub-dominant levels. Measuring g at four magnetic fields with cavity shifts spanning thirty times the final g-value uncertainty provides a check on the calculated cavity shifts. Magnetic field fluctuations limit the measurement of g by adding a noise-model dependence to the extraction of the cyclotron and anomaly frequencies from their resonance lines; the relative agreement of two line-splitting methods quantifies a lineshape model uncertainty. New techniques promise to increase field stability, narrow the resonance lines, and accelerate the measurement cycle. The measured g allows tests for physics beyond the Standard Model through searches for its temporal variation and comparisons with a “theoretical” g-value calculated from quantum electrodynamics and an independently measured fine structure constant.
The BASE collaboration aims to measure antimatter systems with the highest precision in order to perform a rigorous test of CPT symmetry and search for physics beyond the Standard Model. As part of the BASE collaboration, we pursue the development of quantum logic inspired cooling and detection techniques for g-factor measurements of (anti-)protons. Implementing these methods requires full quantum-level control of individual antimatter particles confined in cryogenic Penning traps. By mapping the (anti-)proton's internal state onto a co-trapped 9Be+ "logic" ion via free Coulomb coupling in a double-well potential, we can accelerate measurement cycles and push g-factor precision measurements on (anti-)protons toward the quantum limit. Here, we present an overview of the proposed method and the current status of the project, with special emphasis on the new cryogenic multi-Penning-trap stack and the proton detection system.
In this thesis is presented the realisation of `The Geonium Chip', a novel planar Penning trap. The chip is designed with the goal of building a truly scalable planar Penning trap, while retaining the accuracy of 3D traps. Manufactured with conventional metalon- silicon microfabrication techniques, the chip takes the 5 electrodes of the compensated cylindrical trap and projects them onto a ground-plane surface, thus forming the basis for its layout by reducing the electrode shape to an array of at rectangular surfaces. In this thesis I describe the conception, design and construction of a full cryogenic set-up, including the magnetics, for trapping and observing a single electron in the Geonium Chip Penning trap. The cyclotron mode of the trapped electron lies in the microwave regime, and thus the Geonium Chip has the potential to become a powerful building block for quantum microwave circuits, with coherent coupling to the cyclotron degree of freedom. This will also allow non-destructive measurement and interaction with the spin state of the electron. The development of the experimental process is detailed from scratch including the design, fabrication, and testing of the Geonium Chip, as well as the design, fabrication and testing of the experimental apparatus. The original solutions and space saving designs developed as part of the construction process are detailed, such as the custom on-chip cryogenic vacuum chamber, planar magnetic field source, and the LED-based electron loading system. The vacuum chamber and control systems are also described, and the in-house manufacturing capabilities of the Geonium group are detailed at length, with an emphasis on rapid prototyping high-accuracy components suitable for experimental use. The apparatus built within this PhD is within a few weeks of performing the first loading of electrons into the chip trap.