Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1303.1359 · Physical Review Letters

Resolution of Single Spin Flips of a Single Proton

Andreas H. Mooser, Holger Kracke, K. Blaum, S. A. Bräuninger, Kurt Franke, C. Leiteritz, W. Quint, C. C. Rodegheri, S. Ulmer, J. Walz

Published Apr 4, 2013• 54 citations
arXivHTMLPDF

Abstract

The spin magnetic moment of a single proton in a cryogenic Penning trap was coupled to the particle's axial motion with a superimposed magnetic bottle. Jumps in the oscillation frequency indicate spin flips and were identified using a Bayesian analysis.
DOI
10.1103/physrevlett.110.140405

Related papers

Direct observation of a single proton in a Penning trap. Towards a direct measurement of the proton g-factor

S. Kreim

This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i. e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10−7. The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range.

•Jun 29, 2009•0 citations

Squeezing the noise of the axial oscillation in ion traps

Irene Marzoli, Paolo Tombesi

The motions of a charged particle in a Penning trap are coupled by means of a magnetic bottle.

Annual Meeting Optical Society of America•Jan 1, 1993•0 citations

Coherent spectroscopy with a single antiproton spin

B. M. Latacz, Stefan Erlewein, M. Fleck +22 more

Coherent quantum transition spectroscopy is a powerful tool in metrology1, quantum information processing2, magnetometry3 and precision tests of the standard model4. It was applied with great success in proton and deuteron magnetic moment measurements5, which culminated in maser spectroscopy with sub-parts-per-trillion resolution6 and many other experiments at the forefront of physics7. All of these experiments were performed on macroscopic ensembles of particles, whereas the coherent spectroscopy of a ‘free’ single nuclear spin has, to our knowledge, never been reported before. Here we demonstrate coherent quantum transition spectroscopy of the spin of a single antiproton stored in a cryogenic Penning-trap system. We apply a multi-trap technique8, detect the antiproton spin state using the continuous Stern–Gerlach effect9 and transport the particle to the homogeneous magnetic field of a precision trap (PT). Here we induce the coherent dynamics and analyse the result by quantum-projection measurements in the analysis trap (AT)10. We observe, for the first time, Rabi oscillations of an antiproton spin and achieve in time-series measurements spin-inversion probabilities greater than 80% at spin coherence times of about 50 s. Scans of single-particle spin resonances show inversions greater than 70%, at transition linewidths 16 times narrower than in previous measurements8, limited by cyclotron frequency measurement decoherence. This achievement marks a notable step towards at least tenfold improved tests of matter/antimatter symmetry using proton and antiproton magnetic moments. Coherent quantum transition spectroscopy of the spin of a single antiproton is reported, demonstrating Rabi oscillations of the spin and enabling improved measurement of matter/antimatter symmetry using proton and antiproton magnetic moments.

Nature•Jul 23, 2025•12 citations

Demonstration of a Spherical Penning Trap for Single Electrons

Zirui Fang, Xing Fan

A spherical Penning trap has well-separated, clean microwave resonances, making it attractive for precision measurements of the electron magnetic moment and for dark-photon and axion searches with trapped electrons. We demonstrate single-electron trapping in a spherical Penning trap and characterize its microwave resonance structure. The design, single-electron detection, microwave mode characterization, and advantages of this geometry are presented.

physics.atom-phCross-listedarXiv:2606.03639•Jun 3, 2026

Spin-flip loss in magnetic traps for ultracold neutrons

A. Steyerl, E. Gutsmiedl

A particle with spin and magnetic-dipole moment can be trapped in certain suitable magnetic-field configurations only as long as its spin remains aligned with the field direction as it moves through the trap. Here, we extend earlier analyses of spin-flip probabilities, which lead to storage loss for ultracold neutrons, and present arguments indicating that some of the earlier results should be multiplied by a factor of two.

Physical Review C•Oct 13, 2020•1 citation

Elementary Laser‐Less Quantum Logic Operations with (Anti‐)Protons in Penning Traps

Diana Nitzschke, Marius Schulte, Malte Niemann +5 more

Abstract Static magnetic field gradients superimposed on the electromagnetic trapping potential of a Penning trap can be used to implement laser‐less spin–motion couplings that allow the realization of elementary quantum logic operations in the radio‐frequency regime. An important scenario of practical interest is the application to g ‐factor measurements with single (anti‐)protons to test the fundamental charge, parity, time reversal (CPT) invariance as pursued in the Baryon Antibaryon Symmetry Experiment (BASE) collaboration. The classical and quantum behavior of a charged particle in a Penning trap with a superimposed magnetic field gradient is discussed. Using analytic and numerical calculations, it is found that it is possible to carry out a SWAP gate between the spin and the motional qubit of a single (anti‐)proton with high fidelity, provided the particle has been initialized in the motional ground state. The implications of the findings for the realization of quantum logic spectroscopy in this system are discussed.

arXiv:1912.02046•Advanced Quantum Technologies•Jun 16, 2020•10 citations
This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i. e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10−7. The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range.
Coherent quantum transition spectroscopy is a powerful tool in metrology1, quantum information processing2, magnetometry3 and precision tests of the standard model4. It was applied with great success in proton and deuteron magnetic moment measurements5, which culminated in maser spectroscopy with sub-parts-per-trillion resolution6 and many other experiments at the forefront of physics7. All of these experiments were performed on macroscopic ensembles of particles, whereas the coherent spectroscopy of a ‘free’ single nuclear spin has, to our knowledge, never been reported before. Here we demonstrate coherent quantum transition spectroscopy of the spin of a single antiproton stored in a cryogenic Penning-trap system. We apply a multi-trap technique8, detect the antiproton spin state using the continuous Stern–Gerlach effect9 and transport the particle to the homogeneous magnetic field of a precision trap (PT). Here we induce the coherent dynamics and analyse the result by quantum-projection measurements in the analysis trap (AT)10. We observe, for the first time, Rabi oscillations of an antiproton spin and achieve in time-series measurements spin-inversion probabilities greater than 80% at spin coherence times of about 50 s. Scans of single-particle spin resonances show inversions greater than 70%, at transition linewidths 16 times narrower than in previous measurements8, limited by cyclotron frequency measurement decoherence. This achievement marks a notable step towards at least tenfold improved tests of matter/antimatter symmetry using proton and antiproton magnetic moments. Coherent quantum transition spectroscopy of the spin of a single antiproton is reported, demonstrating Rabi oscillations of the spin and enabling improved measurement of matter/antimatter symmetry using proton and antiproton magnetic moments.
Abstract Static magnetic field gradients superimposed on the electromagnetic trapping potential of a Penning trap can be used to implement laser‐less spin–motion couplings that allow the realization of elementary quantum logic operations in the radio‐frequency regime. An important scenario of practical interest is the application to g ‐factor measurements with single (anti‐)protons to test the fundamental charge, parity, time reversal (CPT) invariance as pursued in the Baryon Antibaryon Symmetry Experiment (BASE) collaboration. The classical and quantum behavior of a charged particle in a Penning trap with a superimposed magnetic field gradient is discussed. Using analytic and numerical calculations, it is found that it is possible to carry out a SWAP gate between the spin and the motional qubit of a single (anti‐)proton with high fidelity, provided the particle has been initialized in the motional ground state. The implications of the findings for the realization of quantum logic spectroscopy in this system are discussed.