Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Physical Review Letters

Direct Measurement of the Free Cyclotron Frequency of a Single Particle in a Penning Trap

S. Ulmer, K. Blaum, Holger Kracke, Andreas H. Mooser, W. Quint, C. C. Rodegheri, J. Walz

Published Sep 1, 2011• 23 citations
Publisher

Abstract

A measurement scheme for the direct determination of the free cyclotron frequency ν(c) of a single particle stored in a Penning trap is described. The method is based on the dressed states of mode coupling. In this novel measurement scheme both radial modes of the single trapped particle are simultaneously coupled to the axial oscillation mode.

DOI
10.1103/physrevlett.107.103002

Related papers

Direct observation of a single proton in a Penning trap. Towards a direct measurement of the proton g-factor

S. Kreim

This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i. e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10−7. The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range.

•Jun 29, 2009•0 citations

Quantum non demolition measurement of cyclotron excitations in a Penning trap

Irene Marzoli, Paolo Tombesi

The quantum non-demolition measurement of the cyclotron excitations of an electron confined in a Penning trap could be obtained by measuring the resonance frequency of the axial motion, which is coupled to the cyclotron motion through the relativistic shift of the electron mass.

•Jan 1, 1993•0 citations

Single-Particle Self-Excited Oscillator

Brian D’Urso, Ramon van Handel, Brian Odom +2 more

Electronic feedback is used to self-excite the axial oscillation of a single electron in a Penning trap. Large, stable, easily detected oscillations arise even in an anharmonic potential. Amplitudes are controlled by adjusting the feedback gain, and frequencies can be made nearly independent of amplitude fluctuations. Quantum jump spectroscopy of a perpendicular cyclotron motion reveals the absolute temperature and amplitude of the self-excited oscillation. The possibility to quickly measure parts per billion frequency shifts could open the way to improved measurements of e(-), e(+), p, and (-)p magnetic moments.

Physical Review Letters•Mar 23, 2005•35 citations

Measurements of Motional Frequencies for Laser-cooled Ions in a Penning Trap

Hidetsuka Imajo, Shinji Urabe, Kazuhiro Hayasaka +1 more

The characteristics of laser-cooled Be+ ions stored in a Penning trap are reported. Be+ ions are cooled by a laser to approximately 300 mK and the cyclotron and axial frequencies of the cooled ions are measured by a laser fluorescence technique. In addition, ion resonances are observed when several kinds of ions are trapped with Be+ ions.

Journal of Modern Optics•Feb 1, 1992•16 citations

Measuring the cyclotron state of a trapped electron

Stefano Mancini, Paolo Tombesi

We propose the cyclotron state retrieval of an electron trapped in a Penning trap by using different measurement schemes based on suitable modifications of the applied electromagnetic fields, and exploiting the axial degree of freedom as a probe. A test for the matter-antimatter symmetry of the quantum state is proposed.

arXiv:quant-ph/9707012•Physical Review A•Oct 1, 1997•6 citations

Mode coupling in a Penning trap:πpulses and a classical avoided crossing

Eric Cornell, Robert M. Weisskoff, Kevin Robert Boyce +1 more

An inhomogeneous radiofrequency electric field can couple the cyclotron and axial modes of a single ion in a Penning trap. The classical equations of motion are the same as those of a driven quantum-mechanical two-level system. We discuss an analog of the \ensuremath{\pi} pulse, which can exchange mode actions, and an analog of the avoided crossing. Experimental illustrations are presented.

Physical Review A•Jan 1, 1990•184 citations
A measurement scheme for the direct determination of the free cyclotron frequency ν(c) of a single particle stored in a Penning trap is described. The method is based on the dressed states of mode coupling. In this novel measurement scheme both radial modes of the single trapped particle are simultaneously coupled to the axial oscillation mode.
This PhD thesis presents experiments performed on a single proton stored in a Penning trap. The eigenmotion of an isolated, free proton could be detected electronically via a coupling to a resonance circuit. This represents a non-destructive measurement, i. e. the particle is not lost during the measurement. The free cyclotron frequency emerging from the measured eigenfrequencies is one of the two frequencies required for the determination of the magnetic moment. This enables a direct determination of the g-factor contrary to already existing works. Design, developing, and commissioning of the experimental setup have been accomplished within the scope of this work leading to a measuring accuracy of 10−7. The technical challenges for the determination of the second frequency (the Larmor frequency) arising from the smallness of the magnetic moment were mastered. Since the spin state required for this measurement is an internal degree of freedom, it can only be accessed through a coupling of the magnetic moment to the eigenmotion. A novel, hybrid penning trap is presented in this work, which imprints the spin information onto the eigenmotion, thus, realizing a quantum jump spectrometer. Therewith, the frequency shift of the two spin states resulting from the magnetic coupling reaches for the first time an electronically detectable range.
Electronic feedback is used to self-excite the axial oscillation of a single electron in a Penning trap. Large, stable, easily detected oscillations arise even in an anharmonic potential. Amplitudes are controlled by adjusting the feedback gain, and frequencies can be made nearly independent of amplitude fluctuations. Quantum jump spectroscopy of a perpendicular cyclotron motion reveals the absolute temperature and amplitude of the self-excited oscillation. The possibility to quickly measure parts per billion frequency shifts could open the way to improved measurements of e(-), e(+), p, and (-)p magnetic moments.