Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Precision Electromagnetic Measurements

Evaluation of Systematic Uncertainty Induced by Excess Micromotion in NIMT Optical Atomic Clock

R. Kaewuam, P. Phoonthong

Published Sep 1, 2026• 0 citations
Publisher

Abstract

Excess micromotion is a systematic effect that can cause a significant frequency shift to an optical atomic clock based on trapped ions. It is a rapid driven motion that is typically caused by a stray electric field in the trap. This fast motion results in motion-induced shifts of the clock frequency. Here we present the measurement of excess micromotion in a linear Paul trap at National Institute of Metrology Thailand (NIMT). After the stray field compensation, the estimated second-order Doppler shift and scalar Stark shift of the 435-nm clock transition in171Yb+are –1.5(8) × 10–18and 1.3(7) × 10–17, respectively.

DOI
10.1109/cpem68396.2026.11756287

Related papers

Evaluation of trap-induced systematic frequency shifts for a multi-ion optical clock at the 10−19level

Jonas Keller, T. Burgermeister, Dimitri Kalincev +2 more

In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .

arXiv:1512.05677•Journal of Physics Conference Series•Jun 1, 2016•29 citations

Minimization of ion micromotion in a Paul trap

Dana J. Berkeland, J.D. Miller, Jonas Bergquist +2 more

Micromotion of ions in Paul traps has several adverse effects, including alterations of atomic transition line shapes, significant second-order Doppler shifts in high-accuracy studies, and limited confinement time in the absence of cooling. The ac electric field that causes the micromotion may also induce significant Stark shifts in atomic transitions. We describe three methods of detecting micromotion. The first relies on the change of the average ion position as the trap potentials are changed. The second monitors the amplitude of the sidebands of a narrow atomic transition, caused by the first-order Doppler shift due to the micromotion. The last technique detects the Doppler shift induced modulation of the fluorescence rate of a broad atomic transition. We discuss the detection sensitivity of each method to Doppler and Stark shifts, and show experimental results using the last technique.

Journal of Applied Physics•May 15, 1998•733 citations

Second-order Doppler frequency shifts of trapped ions in a linear Paul trap

S. N. Miao, Jianwei Zhang, Yajing Zheng +5 more

The accurate evaluation of the second-order Doppler frequency shift (SODFS) of trapped ions in a linear Paul trap has been studied with experiments and molecular dynamics (MD) simulations. The motion of trapped ions in the trap has three contributions, and we focus on the ion excess micromotion, which is rarely discussed when evaluating the SODFS of ions. Based on the hypothesis that the ion density is uniformly distributed in the radial direction, we propose a model to accurately evaluate the total SODFS for an ion ensemble with temperature less than 100 mK, which consists of three contributions of ion motion. The effectiveness of the model has been verified by MD simulation, and the experimental results of the excess micromotion of trapped ions are consistent with the theory. We believe that our model offers advantages in accurately evaluating the SODFS for the ion trap, especially those of laser-cooled ion microwave clocks based on large ion clouds.

arXiv:2206.08136•Physical Review A•Sep 29, 2022•8 citations

Phase shifts and fluctuations from motional, relativistic, and dark-matter effects in ion-trap clocks

Alexander Bott, Fabio Di Pumpo, Enno Giese

Ions possess both center-of-mass motion and internal states, rendering trapped-ion optical clocks susceptible to perturbations of both degrees of freedom, which results in systematic shifts and fluctuations with motional and relativistic origins. We develop a quantum theory that connects these effects to filter functions determined by the employed pulse sequences and show how the interrogation can be tailored to suppress or enhance specific perturbations. Our treatment includes laser frequency noise and motional effects such as recoil and Doppler shifts, micromotion and excess micromotion, as well as state-dependent trap imperfections and accelerations, e.g., caused by Stark shifts. We further account for relativistic effects including time dilation and the mass defect, and show how the same framework can be applied to hypothetical dark-matter signals. By considering ensemble-averaged phases and their variances, we characterize both systematic shifts and fluctuations, while asynchronous operation relative to the Paul-trap drive allows motional fluctuations to average down between runs. Our results provide a unified framework for characterizing and controlling the systematic and statistical contributions that determine the trueness and precision of trapped-ion optical clocks.

quant-pharXiv:2610.27994•Oct 21, 2026•0 citations

Micromotion minimisation by synchronous detection of parametrically excited motion

D. P. Nadlinger, P. Drmota, D. Main +6 more

Precise control of charged particles in radio-frequency (Paul) traps requires minimising excess micromotion induced by stray electric fields. We present a method to detect and compensate such fields through amplitude modulation of the radio-frequency trapping field. Modulation at frequencies close to the motional modes of the trapped particle excites coherent motion whose amplitude linearly depends on the stray field. In trapped-ion experiments, this motion can be detected by recording the arrival times of photons scattered during laser cooling. Only a single laser beam is required to resolve fields in multiple directions. In a demonstration using a $^{88}\mathrm{Sr}^{+}$ ion in a surface electrode trap, we achieve a sensitivity of $0.1\, \mathrm{V}\, \mathrm{m}^{-1}\, /\, \sqrt{\mathrm{Hz}}$ and a minimal uncertainty of $0.015\, \mathrm{V}\, \mathrm{m}^{-1}$.

arXiv:2107.00056•Jun 30, 2021•13 citations

Precise determination of micromotion for trapped-ion optical clocks

J. Keller, H. L. Partner, T. Burgermeister +1 more

As relative systematic frequency uncertainties in trapped-ion spectroscopy are approaching the low 10−18 range, motional frequency shifts account for a considerable fraction of the uncertainty budget. Micromotion, a driven motion fundamentally connected to the principle of the Paul trap, is a particular concern in these systems. In this article, we experimentally investigate at this level three common methods for minimizing and determining the micromotion amplitude. We develop a generalized model for a quantitative application of the photon-correlation technique, which is applicable in the commonly encountered regime where the transition linewidth is comparable to the rf drive frequency. We show that a fractional frequency uncertainty due to the 2nd-order Doppler shift below |Δν/ν|=1×10−20 can be achieved. The quantitative evaluation is verified in an interleaved measurement with the conceptually simpler resolved sideband method. If not performed deep within the Lamb-Dicke regime, a temperature-dependent offset at the level of 10−19 is observed in resolved sideband measurements due to sampling of intrinsic micromotion. By direct comparison with photon-correlation measurements, we show that the simple to implement parametric heating method is sensitive to micromotion at the level of |Δν/ν|=1×10−20 as well.

arXiv:1505.05907•Journal of Applied Physics•Sep 8, 2015•129 citations
Excess micromotion is a systematic effect that can cause a significant frequency shift to an optical atomic clock based on trapped ions. It is a rapid driven motion that is typically caused by a stray electric field in the trap. This fast motion results in motion-induced shifts of the clock frequency. Here we present the measurement of excess micromotion in a linear Paul trap at National Institute of Metrology Thailand (NIMT). After the stray field compensation, the estimated second-order Doppler shift and scalar Stark shift of the 435-nm clock transition in171Yb+are –1.5(8) × 10–18and 1.3(7) × 10–17, respectively.
In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .
Micromotion of ions in Paul traps has several adverse effects, including alterations of atomic transition line shapes, significant second-order Doppler shifts in high-accuracy studies, and limited confinement time in the absence of cooling. The ac electric field that causes the micromotion may also induce significant Stark shifts in atomic transitions. We describe three methods of detecting micromotion. The first relies on the change of the average ion position as the trap potentials are changed. The second monitors the amplitude of the sidebands of a narrow atomic transition, caused by the first-order Doppler shift due to the micromotion. The last technique detects the Doppler shift induced modulation of the fluorescence rate of a broad atomic transition. We discuss the detection sensitivity of each method to Doppler and Stark shifts, and show experimental results using the last technique.
The accurate evaluation of the second-order Doppler frequency shift (SODFS) of trapped ions in a linear Paul trap has been studied with experiments and molecular dynamics (MD) simulations. The motion of trapped ions in the trap has three contributions, and we focus on the ion excess micromotion, which is rarely discussed when evaluating the SODFS of ions. Based on the hypothesis that the ion density is uniformly distributed in the radial direction, we propose a model to accurately evaluate the total SODFS for an ion ensemble with temperature less than 100 mK, which consists of three contributions of ion motion. The effectiveness of the model has been verified by MD simulation, and the experimental results of the excess micromotion of trapped ions are consistent with the theory. We believe that our model offers advantages in accurately evaluating the SODFS for the ion trap, especially those of laser-cooled ion microwave clocks based on large ion clouds.
Ions possess both center-of-mass motion and internal states, rendering trapped-ion optical clocks susceptible to perturbations of both degrees of freedom, which results in systematic shifts and fluctuations with motional and relativistic origins. We develop a quantum theory that connects these effects to filter functions determined by the employed pulse sequences and show how the interrogation can be tailored to suppress or enhance specific perturbations. Our treatment includes laser frequency noise and motional effects such as recoil and Doppler shifts, micromotion and excess micromotion, as well as state-dependent trap imperfections and accelerations, e.g., caused by Stark shifts. We further account for relativistic effects including time dilation and the mass defect, and show how the same framework can be applied to hypothetical dark-matter signals. By considering ensemble-averaged phases and their variances, we characterize both systematic shifts and fluctuations, while asynchronous operation relative to the Paul-trap drive allows motional fluctuations to average down between runs. Our results provide a unified framework for characterizing and controlling the systematic and statistical contributions that determine the trueness and precision of trapped-ion optical clocks.
Precise control of charged particles in radio-frequency (Paul) traps requires minimising excess micromotion induced by stray electric fields. We present a method to detect and compensate such fields through amplitude modulation of the radio-frequency trapping field. Modulation at frequencies close to the motional modes of the trapped particle excites coherent motion whose amplitude linearly depends on the stray field. In trapped-ion experiments, this motion can be detected by recording the arrival times of photons scattered during laser cooling. Only a single laser beam is required to resolve fields in multiple directions. In a demonstration using a 88Sr+^{88}\mathrm{Sr}^{+}88Sr+ ion in a surface electrode trap, we achieve a sensitivity of 0.1 V m−1 / Hz0.1\, \mathrm{V}\, \mathrm{m}^{-1}\, /\, \sqrt{\mathrm{Hz}}0.1Vm−1/Hz​ and a minimal uncertainty of 0.015 V m−10.015\, \mathrm{V}\, \mathrm{m}^{-1}0.015Vm−1.
As relative systematic frequency uncertainties in trapped-ion spectroscopy are approaching the low 10−18 range, motional frequency shifts account for a considerable fraction of the uncertainty budget. Micromotion, a driven motion fundamentally connected to the principle of the Paul trap, is a particular concern in these systems. In this article, we experimentally investigate at this level three common methods for minimizing and determining the micromotion amplitude. We develop a generalized model for a quantitative application of the photon-correlation technique, which is applicable in the commonly encountered regime where the transition linewidth is comparable to the rf drive frequency. We show that a fractional frequency uncertainty due to the 2nd-order Doppler shift below |Δν/ν|=1×10−20 can be achieved. The quantitative evaluation is verified in an interleaved measurement with the conceptually simpler resolved sideband method. If not performed deep within the Lamb-Dicke regime, a temperature-dependent offset at the level of 10−19 is observed in resolved sideband measurements due to sampling of intrinsic micromotion. By direct comparison with photon-correlation measurements, we show that the simple to implement parametric heating method is sensitive to micromotion at the level of |Δν/ν|=1×10−20 as well.