Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1512.05677 · Journal of Physics Conference Series

Evaluation of trap-induced systematic frequency shifts for a multi-ion optical clock at the 10−19level

Jonas Keller, T. Burgermeister, Dimitri Kalincev, J. Kiethe, T. E. Mehlstäubler

Published Jun 1, 2016• 29 citations
arXivHTMLPDF

Abstract

In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .

DOI
10.1088/1742-6596/723/1/012027

Related papers

Development and characterization of a linear ion trap for an improved optical clock performance

T. Burgermeister

Single ion frequency standards have demonstrated in several experiments excellent results and are approaching fractional frequency uncertainties of 10^-18. As dominant contributions to the uncertainty are linked to the ion trap properties a further reduction would be possible by an improved ion trap. Due to the interrogation of a single ion these frequency standards are currently limited by the intrinsically low signal-to-noise ratio and require long averaging times on the order of several days. This limitation is critical for various applications that require a high frequency resolution on short timescales. One possibility to improve the clock stability is to increase the number of clock ions. However, this approach further increases the requirements for the ion trap. Therefore, for the realization of a multi-ion clock that aims at simultaneously reducing the frequency stability and uncertainty the control over the characteristics of the ion trap is crucial. This thesis continues previous work towards the realization of a multi-ion optical clock based on ion Coulomb crystals of 115In+ ions which are sympathetically cooled by 172Yb+ ions. The existing design for a segmented linear ion trap has been refined and a reliable trap manufacturing process for a trap based on gold coated aluminium nitride wafers has been developed. Manufacturing tolerances below 10 μm allowed to reduce the axial micromotion amplitudes substantially. For a region of more than 300 μm the uncertainty contribution of the three-dimensional micromotion amplitude is shown to be below 10^-19. Additionally the radial ion heating rate of the trap has been measured to be 1.1 phonons/s for a trap frequency of 490 kHz. The time dilation shift due to the heating rate on the radial trap axis is found to be (2.1 ± 0.3) x 10^-20 1/s. The trap design has also been optimized for a low trap temperature rise due to the applied rf voltage. Trap temperature measurements with Pt100 sensors installed on the trap showed a maximum temperature increase of 1.21 K at an rf voltage amplitude of 1 kV. By comparing the measurement results to FEM simulations the uncertainty contribution of the trap temperature to the black-body radiation shift has been deduced to be 2.4 x 10^-20. As the ion trap provides a high level of control on Coulomb crystals it also provides an ideal test bed for studying atomic many-body systems. This work presents results of the investigations on topological defects in two-dimensional Coulomb crystals. The emphasis was placed on the effects of mass defects and external electric fields on the stability of the topological defects. It is shown that these effects can be used to manipulate and create topological defects deterministically.

•Jan 1, 2019•3 citations

Optical clocks based on linear ion chains with high stability and accuracy

Jonas Keller, Dimitri Kalincev, T. Burgermeister +5 more

Trapped-ion optical clocks are capable of achieving systematic fractional frequency uncertainties of $10^{-18}$ and possibly below. However, the stability of current ion clocks is fundamentally limited by the weak signal of single-ion interrogation. We present an operational, versatile platform for extending clock spectroscopy to arrays of Coulomb crystals consisting of several tens of ions, while allowing systematic shifts as low as $10^{-19}$. The concept is applicable to all clock transitions with low differential electric quadrupole moments. We observe 3D excess micromotion amplitudes of all individual ions inside a Coulomb crystal with nm resolution and prove that the related frequency shifts can be controlled simultaneously at the $10^{-19}$ level. Using this method, we demonstrate regions of $400$ $\mu$m and $2$ mm length in our trap array with time dilation shifts due to micromotion close to $1\times10^{-19}$ and below $10^{-18}$, respectively. Further measurements of the trapping environment and cooling dynamics calculations for mixed In${}^+$ / Yb${}^+$ crystals show that achievable clock uncertainties due to multi-ion operation in our setup are below $1\times10^{-19}$. This work will enable clock operation with multiple ions and open up the possibility of new interrogation schemes which allow optical clock stabilities beyond classical limits.

•Dec 6, 2017•5 citations

Precise determination of micromotion for trapped-ion optical clocks

J. Keller, H. L. Partner, T. Burgermeister +1 more

As relative systematic frequency uncertainties in trapped-ion spectroscopy are approaching the low 10−18 range, motional frequency shifts account for a considerable fraction of the uncertainty budget. Micromotion, a driven motion fundamentally connected to the principle of the Paul trap, is a particular concern in these systems. In this article, we experimentally investigate at this level three common methods for minimizing and determining the micromotion amplitude. We develop a generalized model for a quantitative application of the photon-correlation technique, which is applicable in the commonly encountered regime where the transition linewidth is comparable to the rf drive frequency. We show that a fractional frequency uncertainty due to the 2nd-order Doppler shift below |Δν/ν|=1×10−20 can be achieved. The quantitative evaluation is verified in an interleaved measurement with the conceptually simpler resolved sideband method. If not performed deep within the Lamb-Dicke regime, a temperature-dependent offset at the level of 10−19 is observed in resolved sideband measurements due to sampling of intrinsic micromotion. By direct comparison with photon-correlation measurements, we show that the simple to implement parametric heating method is sensitive to micromotion at the level of |Δν/ν|=1×10−20 as well.

arXiv:1505.05907•Journal of Applied Physics•Sep 8, 2015•129 citations

Spectroscopic characterization of ion motion for an optical clock based on Coulomb crystals

Keller, Jonas

Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.

•Jan 1, 2015•5 citations

Control of the systematic shifts of the strontium ion optical frequency standard at the 10 mHz level

P. Dubé, Alan A. Madej, Maria Tibbo +1 more

An overview of the key methods used to reduce the uncertainty of the systematic shifts of the strontium ion optical frequency standard is presented. An uncertainty of 10 mHz at a clock frequency of 445 THz is obtained, limited by the uncertainty of the blackbody radiation shift. The uncertainty estimates of other shifts such as micromotion and electric quadrupole shifts are on the order of 1 mHz or less. The effectiveness of the methods used to reduce or cancel the shifts is illustrated with experiments comparing two ion traps. One has strong micromotion levels while the other, the reference trap, provides good control over the shifts. Despite nominal shifts of 70 Hz in the trap with large micromotion levels, the agreement with the reference trap is at the sub-Hz level.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2013•0 citations

Progress towards a 40Ca+ optical clock with a fractional uncertainty at the 10−18 level

Yao Huang, Hua Guan, Kelin Gao

We recently reported a 5×10-17level frequency comparison of two40Ca+optical clocks, one of which has fractional frequency uncertainty of 3.4×10-17, limited by the BBR effect. Here we present progress towards a40Ca+optical clock with uncertainty at the 10-18level. The differential static scalar polarizability Δα0 of the40Ca+ion clock transition is obtained by precisely measuring the “magic” rf drive frequency. Δα0 is measured as -7.2653(44)x10-40J m2/V2, the blackbody radiation shift is then calculated to be 0.3790(2) Hz at 300 K. The contribution of the blackbody shift coefficient to the uncertainty of the optical clock at room temperature is reduced to 5.6×10-19, the excess micromotion induced clock uncertainty is also reduced to the 10-19level by choosing the appropriate trap drive frequency. With a suppression of the BBR field temperature uncertainty to the sub-Kelvin level and improved clock stability, a robust, relatively low-cost40Ca+ion clock with uncertainty at 10-18level can be made.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 1, 2017•0 citations
In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .
Single ion frequency standards have demonstrated in several experiments excellent results and are approaching fractional frequency uncertainties of 10^-18. As dominant contributions to the uncertainty are linked to the ion trap properties a further reduction would be possible by an improved ion trap. Due to the interrogation of a single ion these frequency standards are currently limited by the intrinsically low signal-to-noise ratio and require long averaging times on the order of several days. This limitation is critical for various applications that require a high frequency resolution on short timescales. One possibility to improve the clock stability is to increase the number of clock ions. However, this approach further increases the requirements for the ion trap. Therefore, for the realization of a multi-ion clock that aims at simultaneously reducing the frequency stability and uncertainty the control over the characteristics of the ion trap is crucial. This thesis continues previous work towards the realization of a multi-ion optical clock based on ion Coulomb crystals of 115In+ ions which are sympathetically cooled by 172Yb+ ions. The existing design for a segmented linear ion trap has been refined and a reliable trap manufacturing process for a trap based on gold coated aluminium nitride wafers has been developed. Manufacturing tolerances below 10 μm allowed to reduce the axial micromotion amplitudes substantially. For a region of more than 300 μm the uncertainty contribution of the three-dimensional micromotion amplitude is shown to be below 10^-19. Additionally the radial ion heating rate of the trap has been measured to be 1.1 phonons/s for a trap frequency of 490 kHz. The time dilation shift due to the heating rate on the radial trap axis is found to be (2.1 ± 0.3) x 10^-20 1/s. The trap design has also been optimized for a low trap temperature rise due to the applied rf voltage. Trap temperature measurements with Pt100 sensors installed on the trap showed a maximum temperature increase of 1.21 K at an rf voltage amplitude of 1 kV. By comparing the measurement results to FEM simulations the uncertainty contribution of the trap temperature to the black-body radiation shift has been deduced to be 2.4 x 10^-20. As the ion trap provides a high level of control on Coulomb crystals it also provides an ideal test bed for studying atomic many-body systems. This work presents results of the investigations on topological defects in two-dimensional Coulomb crystals. The emphasis was placed on the effects of mass defects and external electric fields on the stability of the topological defects. It is shown that these effects can be used to manipulate and create topological defects deterministically.
Trapped-ion optical clocks are capable of achieving systematic fractional frequency uncertainties of 10−1810^{-18}10−18 and possibly below. However, the stability of current ion clocks is fundamentally limited by the weak signal of single-ion interrogation. We present an operational, versatile platform for extending clock spectroscopy to arrays of Coulomb crystals consisting of several tens of ions, while allowing systematic shifts as low as 10−1910^{-19}10−19. The concept is applicable to all clock transitions with low differential electric quadrupole moments. We observe 3D excess micromotion amplitudes of all individual ions inside a Coulomb crystal with nm resolution and prove that the related frequency shifts can be controlled simultaneously at the 10−1910^{-19}10−19 level. Using this method, we demonstrate regions of 400400400 μ\muμm and 222 mm length in our trap array with time dilation shifts due to micromotion close to 1×10−191\times10^{-19}1×10−19 and below 10−1810^{-18}10−18, respectively. Further measurements of the trapping environment and cooling dynamics calculations for mixed In+{}^++ / Yb+{}^++ crystals show that achievable clock uncertainties due to multi-ion operation in our setup are below 1×10−191\times10^{-19}1×10−19. This work will enable clock operation with multiple ions and open up the possibility of new interrogation schemes which allow optical clock stabilities beyond classical limits.
As relative systematic frequency uncertainties in trapped-ion spectroscopy are approaching the low 10−18 range, motional frequency shifts account for a considerable fraction of the uncertainty budget. Micromotion, a driven motion fundamentally connected to the principle of the Paul trap, is a particular concern in these systems. In this article, we experimentally investigate at this level three common methods for minimizing and determining the micromotion amplitude. We develop a generalized model for a quantitative application of the photon-correlation technique, which is applicable in the commonly encountered regime where the transition linewidth is comparable to the rf drive frequency. We show that a fractional frequency uncertainty due to the 2nd-order Doppler shift below |Δν/ν|=1×10−20 can be achieved. The quantitative evaluation is verified in an interleaved measurement with the conceptually simpler resolved sideband method. If not performed deep within the Lamb-Dicke regime, a temperature-dependent offset at the level of 10−19 is observed in resolved sideband measurements due to sampling of intrinsic micromotion. By direct comparison with photon-correlation measurements, we show that the simple to implement parametric heating method is sensitive to micromotion at the level of |Δν/ν|=1×10−20 as well.
Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.
An overview of the key methods used to reduce the uncertainty of the systematic shifts of the strontium ion optical frequency standard is presented. An uncertainty of 10 mHz at a clock frequency of 445 THz is obtained, limited by the uncertainty of the blackbody radiation shift. The uncertainty estimates of other shifts such as micromotion and electric quadrupole shifts are on the order of 1 mHz or less. The effectiveness of the methods used to reduce or cancel the shifts is illustrated with experiments comparing two ion traps. One has strong micromotion levels while the other, the reference trap, provides good control over the shifts. Despite nominal shifts of 70 Hz in the trap with large micromotion levels, the agreement with the reference trap is at the sub-Hz level.
We recently reported a 5×10-17level frequency comparison of two40Ca+optical clocks, one of which has fractional frequency uncertainty of 3.4×10-17, limited by the BBR effect. Here we present progress towards a40Ca+optical clock with uncertainty at the 10-18level. The differential static scalar polarizability Δα0 of the40Ca+ion clock transition is obtained by precisely measuring the “magic” rf drive frequency. Δα0 is measured as -7.2653(44)x10-40J m2/V2, the blackbody radiation shift is then calculated to be 0.3790(2) Hz at 300 K. The contribution of the blackbody shift coefficient to the uncertainty of the optical clock at room temperature is reduced to 5.6×10-19, the excess micromotion induced clock uncertainty is also reduced to the 10-19level by choosing the appropriate trap drive frequency. With a suppression of the BBR field temperature uncertainty to the sub-Kelvin level and improved clock stability, a robust, relatively low-cost40Ca+ion clock with uncertainty at 10-18level can be made.