Frequency ratio measurement of Al⁺ at the 10⁻¹⁸ level

Fabian Dawel

Published Jan 1, 2026• 0 citations
Publisher

Abstract

The invention of the atomic clock has enabled applications like the global navigation satellite system, are important for telecommunication and are used for the definition of the SI second. Nowadays, optical clocks allow for measurement of height differences on the centimeter scale and can be employed for tests of the standard model of particle physics. Among the various implementations of optical clocks, this thesis focuses on an Al⁺ clock. For this work an optical resonator is examined, which enables the simultaneous frequency stabilization of two laser on the same mirror pair through the use of a dual-wavelength coating. Various contributions on the frequency stability are characterized and correlations are investigated. This cavity enables high fidelities in coherent manipulation of trapped ions, as required to operate the Al⁺ clock. This thesis partly builds upon the findings presented in Ref. Kramer, 2023. The setup and the systematic shifts are revisited and a detailed evaluation of the shifts is conducted, resulting in a total fractional frequency uncertainty of 1.6×10⁻¹⁸. The biggest contribution is from an ac-Stark shift induced by cooling during the clock interrogation, resulting in a shift of −9.3(1.1) × 10⁻¹⁸. The cooling reduces the second order Doppler shift to −1.6(0.2)×10⁻¹⁸. Additionally, a position dependent micromotion of the ion was investigated, which contributes an uncertainty of 0.38 × 10⁻¹⁸. Moreover, the first-order Doppler shift, servo error, ac-Stark shift of the clock laser and the phase chirp are determined for the first time, showing uncertainties below 10⁻¹⁸. The first frequency comparison between the Al⁺ clock and the ¹¹⁵In⁺, ¹⁷¹Yb⁺ and ⁸⁷Sr clocks at PTB are demonstrated. Measurements against Sr reveal a stability of the Al+ clock of 5.9 × 10⁻¹⁶ at 1s , which is one of the best single ion clock stabilities to date. All measured frequency ratios fall within the 10⁻¹⁸ uncertainty regime. The ratio between Sr/Al⁺ exhibits a significant deviation of more than 8.6𝜎 from published measurement data, underscoring the importance of inter-institutional frequency ratio measurements to verify the uncertainty budgets and reproducibility of optical clocks.

DOI
10.15488/21807

Related papers

An Al$^+$ clock with $1.6\times10^{-18}$ systematic uncertainty and its frequency ratios

Fabian Dawel, Johannes Krämer, D. Drapier +15 more

Advances in optical clocks motivate a redefinition of the second, requiring rigorous evaluations of systematic uncertainties and robust consistency among the clocks. Here, we report the full evaluation of the systematic frequency shifts of an $^{27}\mathrm{Al}^+$ single-ion clock, and the measurement of its absolute frequency and frequency ratio with a $^{87}$Sr optical lattice clock at PTB. The evaluated total systematic fractional frequency uncertainty is $1.6\times10^{-18}$, mainly limited by the accuracy of the relevant atomic coefficients and by background gas collisions. The absolute frequency of the clock has been measured to be $ν_{\mathrm{Al}^+}=1 121 015 393 207 859.19(24)\,$Hz, obtained by comparison with two primary caesium fountain clocks at PTB. The frequency ratio between the Al and Sr optical clocks has been determined to be $ν_{\mathrm{Al}^+}/ν_{^{87}\mathrm{Sr}}=2.611 701 431 781 462 668(36)$, limited by the accuracy of the Sr clock. This ratio differs by $8.6σ$ and $1.2σ$ from the 2021 and 2025 frequency ratio published by the BACON collaboration, respectively. These results represent an important contribution toward a future redefinition of the second using optical clocks, and underscore the importance of independent measurements of clock-candidate frequency ratios across different institutions.

arXiv:2606.23151•Jun 22, 2026•3 citations

Absolute frequency measurement of an 171Yb lattice clock and optical clock comparisons

Benjamin Rauf

The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.

•May 23, 2018•0 citations

Ticking near the Zero-Point Energy: Towards 1 x 10^-18 Accuracy in Al^+ Optical Clocks

Jwo-Sy Chen

The advancement of optical atomic clocks in the past two decades has motivated many potential applications in navigation, communication, and science. Accurate optical clocks that outperform the current cesium time standard also trigger a discussion about a possible redefinition of the SI second. The 27Al+ quantum logic clocks developed at the National Institute of Standards and Technology (NIST) were the first to achieve the clock fractional frequency uncertainty below 10-17 in 2010. To date, a few research groups around the world have demonstrated optical clocks based on various atomic transitions with fractional frequency uncertainty in the 10-18 range. The accuracy of the previous 27Al+ clocks was limited by the second order Doppler (time dilation) shift and the blackbody shift. Since 2010, the third 27Al+ optical clock is being developed at NIST to achieve a higher accuracy. The frequency uncertainties dominant in the previous clocks are controlled and reduced in the current optical clock. The new design of the ion trap system has reduced significantly both the blackbody radiation shift uncertainty and the time dilation shift uncertainty due to micromotion, while the time dilation shift uncertainty due to the secular motion has been reduced by more than an order of magnitude by operating the optical clock near the three dimensional zero-point energy. Despite those previously dominant uncertainties, several other systematic effects are being evaluated and some other efforts are being made to achieve a total uncertainty towards 1.0 x 10-18. In this thesis, I will document the detail of the construction and evaluation of the current 27Al+ optical clock developed at NIST.

•Jan 1, 2017•4 citations

Atomic clock frequency ratios with fractional uncertainty $\leq 3.2 \times 10^{-18}$

Alexander Aeppli, Willa J. Arthur-Dworschack, Kyle Beloy +24 more

We report high-precision frequency ratio measurements between optical atomic clocks based on $^{27}$Al$^+$, $^{171}$Yb, and $^{87}$Sr. With total fractional uncertainties at or below $3.2 \times 10^{-18}$, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in $^{87}$Sr ratios at approximately $1\times10^{-16}$ and the Al$^+$/Yb ratio at $1.6\times10^{-17}$ in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of $1.3 \times 10^{-16}$ at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.

physics.atom-phCross-listedarXiv:2512.21428•Physical Review Letters•Dec 26, 2025•11 citations

Development and characterization of a transportable aluminum ion quantum logic optical clock setup

Stephan Hannig

At the time of writing, state of the art stationary optical clocks reach 10 −18 sys- tematic fractional frequency uncertainty, which allows for the search of new physics beyond the standard model and lays the foundation for new applications such as chronometric leveling, where height differences relative to the geoid are derived from frequency comparisons among optical clocks. Transportable optical clocks allow for chronometric leveling between distant lo- cations which are not connected by a direct line of sight but via length stabilized optical fiber. Moreover, they facilitate frequency comparisons between distant sta- tionary clocks via subsequent side-by-side comparisons without the necessity of a long-range fiber connection. A transportable optical clock employing a single 40Ca+ ion has been reported and a neutral atom 87Sr lattice clock has been employed in a chronometric leveling campaign. However, these clocks report an estimated systematic fractional frequency uncertainty in the high 10^−17 range, which limits their height resolution to a level of approximately 1 m. 27Al+ has one of the smallest blackbody radiation shifts, small linear and quadratic Zeeman shifts and a negligible quadrupole shift, which makes it a candidate for a highly accurate optical clock. This thesis reports on the development, set-up, and characterization of a transportable 27Al+ clock setup with 40Ca+ as logic ion. The setup is simple, modular, compact, and mechanically stable. Ions of both species are generated via pulsed laser ablation and subsequent photoionization. They are confined in a multi-layer trap with segmented loading and experiment zones. Using a single 40Ca+ ion as probe, heating rates of below 10 quanta per second have been measured in all three directions for trap frequencies around 2π × 2 MHz, and pulsed sideband cooling to mean motional quantum numbers below 0.1 quanta was demonstrated. Imaging close to the diffraction limit with a signal to noise ratio of 800 for 300 ms exposure time on a sCMOS camera was achieved using a single NA = 0.51 biaspheric lens. Simultaneously, a state discrimination error below 10^−5 in 100 µs was obtained using a PMT. From the excess micromotion second order Doppler shift, secular motion second order Doppler shift, BBR shift, and background gas collision shift, a partial systematic fractional frequency uncertainty of 1.7 × 10^−18 was inferred, which is equivalent to a height resolution of ca. 2 cm. Moreover, a highly stable mechanical monolithic enhancement cavity for SHG has been developed and demonstrated to withstand accelerations of 3 g rms for 30 min. It has been operated for an uninterrupted period of 130 h without decay in output power in the mid-UV due to O2 -purging, its sealed design, and material selection, which solves the often observed crystal degradation in UV applications. The cavity has been employed in the 27Al+ logic laser system. In conclusion, it has been shown that an 27Al+ ion quantum logic optical clock operated in the present transportable setup could reach an estimated systematic fractional frequency uncertainty of 1.7 × 10^−18 , provided that all other shifts, such as the second order Zeeman shift, are negligible. This paves the way towards chronometric leveling with an unprecedented height resolution of about 2 cm.

•Jan 1, 2018•0 citations

A dual species optical atomic clock

Martin Steinel

Frequency standards based on optical transitions between electronic states of trapped ions have reached uncertainties below 10−18 [1]. The Stark shift caused by room-temperature blackbody radiation (BBR) causes the largest correction for most high-performance optical clock. The systematic uncertainty of 171Yb+ clocks based on the 2S1/2 (F = 0) → 2D3/2 (F = 2) electric quadrupole (E2) and 2S1/2 (F = 0) → 2F7/2 (F = 3) electric octupole (E3) transitions is currently limited to 28×10−18 and 1.5×10−18, respectively, by the fractional accuracy of the differential polarizability Δαdc of approximately 2% [2]. In the scope of this thesis, a dual species clock based on 171Yb+ and 88Sr+ ions was set up, operated and evaluated, to overcome this barrier. Since Δαdc is known with a smaller fractional uncertainty of 0.04% for the 2S1/2 → 2D5/2 E2 transition of 88Sr+ [3], this allows for a transfer of Δαdc from 88Sr+ to 171Yb+ following a method proposed in [4]. The optical intensity of a laser is calibrated with the Stark shift it causes on the 88Sr+ clock transition, allowing for the determination of Δαdc of the 171Yb+ clock transitions. This allows for a reduction of the fractional uncertainty of Δαdc for both 171Yb+ clock transitions below 0.4% and clock operation on the E2 and E3 transition with a fractional BBR shift uncertainty of 0.84×10−18 and 0.24×10−18 is enabled, respectively. However the value of Δαdc determined in this thesis does not agree with [2], a fractional offset of approximately 14% is observed. To investigate this discrepancy further, Δαdc is measured in the same manner as in [2] for the 88Sr+ clock transition. The same offset of approximately 14% is found, calling the accuracy of at least one of these methods into question. Finally, the first optical frequency ratio ℛ between the 88Sr+ clock transition and the 171Yb+ E3 transition is measured. The fractional uncertainty of ℛ is 23×10−18. ℛ in combination with the absolute frequency of the E3 transition allows for the determination of the 88Sr+ absolute frequency νSr+ with an uncertainty limited by the caesium references. The value of νSr+ falls outside of the recommended range, but is corroborated by measurements of the same quantity by other institutes [5, 6]. [1] M. Marshall et al., Phys. Rev. Lett. 135, 033201 (2025) [2] N. Huntemann et al., Phys. Rev. Lett. 116, 063001 (2016) [3] T. Lindvall et al., Phys. Rev. Lett. 135, 043402 (2025) [4] M. D. Barrett et al., Phys. Rev. A 100, 043418 (2019) [5] C. Marceau et al., Metrologia 62.4, 045001 (2025) [6] T. Lindvall et al., Phys. Rev. Appl. 24, 044082 (2025)

•Dec 16, 2025•0 citations
The invention of the atomic clock has enabled applications like the global navigation satellite system, are important for telecommunication and are used for the definition of the SI second. Nowadays, optical clocks allow for measurement of height differences on the centimeter scale and can be employed for tests of the standard model of particle physics. Among the various implementations of optical clocks, this thesis focuses on an Al⁺ clock. For this work an optical resonator is examined, which enables the simultaneous frequency stabilization of two laser on the same mirror pair through the use of a dual-wavelength coating. Various contributions on the frequency stability are characterized and correlations are investigated. This cavity enables high fidelities in coherent manipulation of trapped ions, as required to operate the Al⁺ clock. This thesis partly builds upon the findings presented in Ref. Kramer, 2023. The setup and the systematic shifts are revisited and a detailed evaluation of the shifts is conducted, resulting in a total fractional frequency uncertainty of 1.6×10⁻¹⁸. The biggest contribution is from an ac-Stark shift induced by cooling during the clock interrogation, resulting in a shift of −9.3(1.1) × 10⁻¹⁸. The cooling reduces the second order Doppler shift to −1.6(0.2)×10⁻¹⁸. Additionally, a position dependent micromotion of the ion was investigated, which contributes an uncertainty of 0.38 × 10⁻¹⁸. Moreover, the first-order Doppler shift, servo error, ac-Stark shift of the clock laser and the phase chirp are determined for the first time, showing uncertainties below 10⁻¹⁸. The first frequency comparison between the Al⁺ clock and the ¹¹⁵In⁺, ¹⁷¹Yb⁺ and ⁸⁷Sr clocks at PTB are demonstrated. Measurements against Sr reveal a stability of the Al+ clock of 5.9 × 10⁻¹⁶ at 1s , which is one of the best single ion clock stabilities to date. All measured frequency ratios fall within the 10⁻¹⁸ uncertainty regime. The ratio between Sr/Al⁺ exhibits a significant deviation of more than 8.6𝜎 from published measurement data, underscoring the importance of inter-institutional frequency ratio measurements to verify the uncertainty budgets and reproducibility of optical clocks.
An Al+^++ clock with 1.6×10−181.6\times10^{-18}1.6×10−18 systematic uncertainty and its frequency ratios
Advances in optical clocks motivate a redefinition of the second, requiring rigorous evaluations of systematic uncertainties and robust consistency among the clocks. Here, we report the full evaluation of the systematic frequency shifts of an 27Al+^{27}\mathrm{Al}^+27Al+ single-ion clock, and the measurement of its absolute frequency and frequency ratio with a 87^{87}87Sr optical lattice clock at PTB. The evaluated total systematic fractional frequency uncertainty is 1.6×10−181.6\times10^{-18}1.6×10−18, mainly limited by the accuracy of the relevant atomic coefficients and by background gas collisions. The absolute frequency of the clock has been measured to be νAl+=1121015393207859.19(24) ν_{\mathrm{Al}^+}=1 121 015 393 207 859.19(24)\,νAl+​=1121015393207859.19(24)Hz, obtained by comparison with two primary caesium fountain clocks at PTB. The frequency ratio between the Al and Sr optical clocks has been determined to be νAl+/ν87Sr=2.611701431781462668(36)ν_{\mathrm{Al}^+}/ν_{^{87}\mathrm{Sr}}=2.611 701 431 781 462 668(36)νAl+​/ν87Sr​=2.611701431781462668(36), limited by the accuracy of the Sr clock. This ratio differs by 8.6σ8.6σ8.6σ and 1.2σ1.2σ1.2σ from the 2021 and 2025 frequency ratio published by the BACON collaboration, respectively. These results represent an important contribution toward a future redefinition of the second using optical clocks, and underscore the importance of independent measurements of clock-candidate frequency ratios across different institutions.
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
The advancement of optical atomic clocks in the past two decades has motivated many potential applications in navigation, communication, and science. Accurate optical clocks that outperform the current cesium time standard also trigger a discussion about a possible redefinition of the SI second. The 27Al+ quantum logic clocks developed at the National Institute of Standards and Technology (NIST) were the first to achieve the clock fractional frequency uncertainty below 10-17 in 2010. To date, a few research groups around the world have demonstrated optical clocks based on various atomic transitions with fractional frequency uncertainty in the 10-18 range. The accuracy of the previous 27Al+ clocks was limited by the second order Doppler (time dilation) shift and the blackbody shift. Since 2010, the third 27Al+ optical clock is being developed at NIST to achieve a higher accuracy. The frequency uncertainties dominant in the previous clocks are controlled and reduced in the current optical clock. The new design of the ion trap system has reduced significantly both the blackbody radiation shift uncertainty and the time dilation shift uncertainty due to micromotion, while the time dilation shift uncertainty due to the secular motion has been reduced by more than an order of magnitude by operating the optical clock near the three dimensional zero-point energy. Despite those previously dominant uncertainties, several other systematic effects are being evaluated and some other efforts are being made to achieve a total uncertainty towards 1.0 x 10-18. In this thesis, I will document the detail of the construction and evaluation of the current 27Al+ optical clock developed at NIST.
Atomic clock frequency ratios with fractional uncertainty ≤3.2×10−18\leq 3.2 \times 10^{-18}≤3.2×10−18
We report high-precision frequency ratio measurements between optical atomic clocks based on 27^{27}27Al+^++, 171^{171}171Yb, and 87^{87}87Sr. With total fractional uncertainties at or below 3.2×10−183.2 \times 10^{-18}3.2×10−18, these measurements meet an important milestone criterion for redefinition of the second in the International System of Units. Discrepancies in 87^{87}87Sr ratios at approximately 1×10−161\times10^{-16}1×10−16 and the Al+^++/Yb ratio at 1.6×10−171.6\times10^{-17}1.6×10−17 in fractional units compared to our previous measurements underscore the importance of repeated, high-precision comparisons by different laboratories. A key innovation in this work is the use of a common ultrastable reference delivered to all clocks via a 3.6 km phase-stabilized fiber link between two institutions. Derived from a cryogenic single-crystal silicon cavity, this reference improves comparison stability by a factor of 2 to 3 over previous systems, with an optical lattice clock ratio achieving a fractional instability of 1.3×10−161.3 \times 10^{-16}1.3×10−16 at 1 second. By enabling faster comparisons, this stability will improve sensitivity to non-white noise processes and other underlying limits of state-of-the-art optical frequency standards.
At the time of writing, state of the art stationary optical clocks reach 10 −18 sys- tematic fractional frequency uncertainty, which allows for the search of new physics beyond the standard model and lays the foundation for new applications such as chronometric leveling, where height differences relative to the geoid are derived from frequency comparisons among optical clocks. Transportable optical clocks allow for chronometric leveling between distant lo- cations which are not connected by a direct line of sight but via length stabilized optical fiber. Moreover, they facilitate frequency comparisons between distant sta- tionary clocks via subsequent side-by-side comparisons without the necessity of a long-range fiber connection. A transportable optical clock employing a single 40Ca+ ion has been reported and a neutral atom 87Sr lattice clock has been employed in a chronometric leveling campaign. However, these clocks report an estimated systematic fractional frequency uncertainty in the high 10^−17 range, which limits their height resolution to a level of approximately 1 m. 27Al+ has one of the smallest blackbody radiation shifts, small linear and quadratic Zeeman shifts and a negligible quadrupole shift, which makes it a candidate for a highly accurate optical clock. This thesis reports on the development, set-up, and characterization of a transportable 27Al+ clock setup with 40Ca+ as logic ion. The setup is simple, modular, compact, and mechanically stable. Ions of both species are generated via pulsed laser ablation and subsequent photoionization. They are confined in a multi-layer trap with segmented loading and experiment zones. Using a single 40Ca+ ion as probe, heating rates of below 10 quanta per second have been measured in all three directions for trap frequencies around 2π × 2 MHz, and pulsed sideband cooling to mean motional quantum numbers below 0.1 quanta was demonstrated. Imaging close to the diffraction limit with a signal to noise ratio of 800 for 300 ms exposure time on a sCMOS camera was achieved using a single NA = 0.51 biaspheric lens. Simultaneously, a state discrimination error below 10^−5 in 100 µs was obtained using a PMT. From the excess micromotion second order Doppler shift, secular motion second order Doppler shift, BBR shift, and background gas collision shift, a partial systematic fractional frequency uncertainty of 1.7 × 10^−18 was inferred, which is equivalent to a height resolution of ca. 2 cm. Moreover, a highly stable mechanical monolithic enhancement cavity for SHG has been developed and demonstrated to withstand accelerations of 3 g rms for 30 min. It has been operated for an uninterrupted period of 130 h without decay in output power in the mid-UV due to O2 -purging, its sealed design, and material selection, which solves the often observed crystal degradation in UV applications. The cavity has been employed in the 27Al+ logic laser system. In conclusion, it has been shown that an 27Al+ ion quantum logic optical clock operated in the present transportable setup could reach an estimated systematic fractional frequency uncertainty of 1.7 × 10^−18 , provided that all other shifts, such as the second order Zeeman shift, are negligible. This paves the way towards chronometric leveling with an unprecedented height resolution of about 2 cm.
Frequency standards based on optical transitions between electronic states of trapped ions have reached uncertainties below 10−18 [1]. The Stark shift caused by room-temperature blackbody radiation (BBR) causes the largest correction for most high-performance optical clock. The systematic uncertainty of 171Yb+ clocks based on the 2S1/2 (F = 0) → 2D3/2 (F = 2) electric quadrupole (E2) and 2S1/2 (F = 0) → 2F7/2 (F = 3) electric octupole (E3) transitions is currently limited to 28×10−18 and 1.5×10−18, respectively, by the fractional accuracy of the differential polarizability Δαdc of approximately 2% [2]. In the scope of this thesis, a dual species clock based on 171Yb+ and 88Sr+ ions was set up, operated and evaluated, to overcome this barrier. Since Δαdc is known with a smaller fractional uncertainty of 0.04% for the 2S1/2 → 2D5/2 E2 transition of 88Sr+ [3], this allows for a transfer of Δαdc from 88Sr+ to 171Yb+ following a method proposed in [4]. The optical intensity of a laser is calibrated with the Stark shift it causes on the 88Sr+ clock transition, allowing for the determination of Δαdc of the 171Yb+ clock transitions. This allows for a reduction of the fractional uncertainty of Δαdc for both 171Yb+ clock transitions below 0.4% and clock operation on the E2 and E3 transition with a fractional BBR shift uncertainty of 0.84×10−18 and 0.24×10−18 is enabled, respectively. However the value of Δαdc determined in this thesis does not agree with [2], a fractional offset of approximately 14% is observed. To investigate this discrepancy further, Δαdc is measured in the same manner as in [2] for the 88Sr+ clock transition. The same offset of approximately 14% is found, calling the accuracy of at least one of these methods into question. Finally, the first optical frequency ratio ℛ between the 88Sr+ clock transition and the 171Yb+ E3 transition is measured. The fractional uncertainty of ℛ is 23×10−18. ℛ in combination with the absolute frequency of the E3 transition allows for the determination of the 88Sr+ absolute frequency νSr+ with an uncertainty limited by the caesium references. The value of νSr+ falls outside of the recommended range, but is corroborated by measurements of the same quantity by other institutes [5, 6]. [1] M. Marshall et al., Phys. Rev. Lett. 135, 033201 (2025) [2] N. Huntemann et al., Phys. Rev. Lett. 116, 063001 (2016) [3] T. Lindvall et al., Phys. Rev. Lett. 135, 043402 (2025) [4] M. D. Barrett et al., Phys. Rev. A 100, 043418 (2019) [5] C. Marceau et al., Metrologia 62.4, 045001 (2025) [6] T. Lindvall et al., Phys. Rev. Appl. 24, 044082 (2025)