Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Advanced Quantum Technologies

Reflection‐Compensated Orthogonal Non‐Overlapping Uniform Pumping Scheme For Triaxial Serf Atomic Magnetometers

Ying Liu, M.K. Song, Binyue Huang, Yuxuan An, Tong Jin, Zhanchao Liu, Yueyang Zhai

Published Jul 1, 2026• 0 citations
Publisher

Abstract

ABSTRACT Triaxial spin‐exchange relaxation‐free (SERF) atomic magnetometer has attracted widespread attention for its capability of measuring the total magnetic field vector information. In this paper, we propose a triaxial SERF atomic magnetometer through orthogonal non‐overlapping pumping beam with improved atom spin polarization spatial uniformity by using a uniformized pump beam and reflection compensation . The homogenized beams are adopted to achieve uniform transverse polarization, while double‐pass reflection compensation is integrated to realize uniform longitudinal polarization. The polarizability distribution based on an effective optical path‐length formalism was obtained via theoretical simulation. The bandwidth, dispersion curves, stability, and sensitivity were experimentally analyzed under three configurations: uniformized pump beam , gaussian pump beam‐reflection compensation , and uniformized pump beam‐reflection compensation . Results of experiments reveal that the proposed configuration enhances three‐axis bandwidth by roughly 10 and improves X, Y, and Z sensitivities by approximately 35, 60, and 30, respectively, achieving sensitivities of 20.56 fT/(X), 30.75 fT/(Y) and 20.54 fT/(Z) at 140 and 2 mW. These results demonstrate a structurally simple yet highly effective approach for achieving high uniformity and stability in three‐axis vector magnetic sensing, with strong potential for applications such as spatial magnetic‐field mapping and bio‐magnetic measurement research.

DOI
10.1002/qute.70380

Related papers

A Triaxial Dual‐Beam Magnetic Measurement Method Based on Dressed‐Atom Dynamic Evolution Behavior for Miniaturized SERF Atomic Magnetometer

Zhen Li, Xiangyang Zhou, Zihao Lyu +4 more

ABSTRACT Miniaturized spin‐exchange relaxation‐free (SERF) atomic magnetometers have become core sensors for detecting biomagnetic fields, including MEG and MCG, due to their ultra‐high sensitivity and high spatiotemporal resolution. Compared to single‐axis magnetometers, triaxial atomic magnetometers are more attractive which can measure comprehensive three‐dimensional magnetic field information. However, traditional triaxial single‐beam or dual‐beam configurations are constrained by limited longitudinal sensitivity or complex optical architectures unsuitable for miniaturized sensors. In this paper, a triaxial dual‐beam magnetic measurement method based on the dynamic evolution of dressed atoms is proposed. The proposed method employs an overlapping pump–probe configuration to simplify the optical sensing architecture while maintaining high magnetic field sensitivity. By utilizing multi‐frequency signal modulation and parallel demodulation, triaxial magnetic vector components are measured simultaneously. Modulation parameters are experimentally optimized based on a systematic analysis of atomic spin dynamics under dual radio‐frequency (RF) fields. Triaxial couplings under various bias magnetic fields are quantitatively analyzed. Experimental validation using a 4 mm vapor cell demonstrates simultaneous triaxial magnetic field measurements, achieving sensitivities of 84.4, 73.2, and 190.7 fT/Hz 1/2 and corresponding bandwidths of 65, 76, and 78 Hz along the x ‐, y ‐, and z ‐axes, respectively.

Advanced Quantum Technologies•Nov 1, 2026•0 citations

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Oct 24, 2022•23 citations

In situ triaxial magnetic field compensation for the spin-exchange-relaxation-free atomic magnetometer

Jiancheng Fang, Jie Qin

The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.

Review of Scientific Instruments•Oct 1, 2012•69 citations

Static bias magnetic field assisted optical modulation triaxial SERF atomic magnetometer

Xiaoyu Li, Bangcheng Han, Shushan Gao +4 more

Abstract High-sensitivity triaxial magnetic field measurements are crucial in various scientific and industrial applications, with spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) standing out for their exceptional sensitivity. However, conventional methods for achieving triaxial measurements in SERF magnetometers typically involve multiple modulated magnetic fields, which introduce crosstalk challenges in array-based configurations. We propose a static bias magnetic field assisted optical modulation triaxial AM to address this limitation. In this configuration, the detuned circularly polarized light is utilized to achieve synchronous modulation of the fictitious magnetic field and pumping rate while incorporating a static bias magnetic field to generate a transverse projection component. We develop a comprehensive triaxial response model that fully considers the effects of the longitudinal spin polarization deflection. Building upon this model, we derive the relationship between the transverse spin component and the triaxial magnetic field and introduce parameter optimization methods to obtain optimal parameters, thus enabling triaxial measurements of 12 fT Hz −1/2 , 10 fT Hz −1/2 , and 15 fT Hz −1/2 along the x-, y -, and z -axes. Our approach offers significant advantages over existing methods, particularly in minimizing crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Moreover, the effective detection of simulated magnetocardiography signals highlights the practical applicability and reliability of the proposed method in real-world scenarios.

Measurement Science and Technology•Nov 7, 2025•2 citations

Pulsed-Modulation Single-Beam Three-Axis Atomic Magnetometer

Shushan Gao, Xiaoyu Li, Jianwei Sheng +5 more

The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz${}^{\text {1/2}}$for the$x$- and$y$-axes, and a longitudinal sensitivity of 70 fT/Hz${}^{\text {1/2}}$for the$z$-axis in a$4\times 4\times 4$mm${}^{\text {3 87}}$Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

Impact of Three-Dimensional Beam-Splitting Light Fields on SERF Polarization and Light-Shift Noise

Jiayi Wei, Xiujie Fang, Xinxiu Zhou +5 more

This paper investigates the impact of pump-beam spatial shaping on spin-polarization uniformity and light-shiftrelated instability in spin-exchange relaxation-free (SERF) atomic magnetometers. Three representative pump profiles—a single Gaussian beam, a flat-top beam, and a split-beam configuration—are studied by combining a steady-state Bloch model with diffusion and a three-dimensional evaluation of the AC-Stark-shift-induced fictitious magnetic field. Simulations show that the Gaussian beam produces strong center-localized pumping with pronounced transverse/longitudinal gradients, whereas the flat-top beam improves transverse uniformity but decays faster along the propagation direction and tends to maintain a larger absolute light shift. By redistributing optical power into multiple beamlets and leveraging diffusion-driven smoothing, split-beam pumping yields a flatter polarization distribution, achieving the smallest depth-averaged polarization non-uniformity among the three cases, and mitigates the spatial inhomogeneity of$B_{\text{LS}}$by suppressing peak intensity. Experimental validation on a SERF platform is performed using an SLM-generated 2 × 2 beamlet array under identical total incident pump power. Frequency-response measurements at$z=0$and$z= \pm 5 ~\text{mm}$demonstrate improved longitudinal response uniformity, and noise-floor measurements in the$20-40 ~\text{Hz}$band exhibit a lower level with weaker$z$dependence, consistent with reduced light-shift-induced noise. The results indicate that split-beam pumping provides an effective and experimentally accessible route to balancing polarization uniformity and light-shift stability in SERF magnetometers.

IEEE International Instrumentation and Measurement Technology Conference•May 1, 2026•0 citations
ABSTRACT Triaxial spin‐exchange relaxation‐free (SERF) atomic magnetometer has attracted widespread attention for its capability of measuring the total magnetic field vector information. In this paper, we propose a triaxial SERF atomic magnetometer through orthogonal non‐overlapping pumping beam with improved atom spin polarization spatial uniformity by using a uniformized pump beam and reflection compensation . The homogenized beams are adopted to achieve uniform transverse polarization, while double‐pass reflection compensation is integrated to realize uniform longitudinal polarization. The polarizability distribution based on an effective optical path‐length formalism was obtained via theoretical simulation. The bandwidth, dispersion curves, stability, and sensitivity were experimentally analyzed under three configurations: uniformized pump beam , gaussian pump beam‐reflection compensation , and uniformized pump beam‐reflection compensation . Results of experiments reveal that the proposed configuration enhances three‐axis bandwidth by roughly 10 and improves X, Y, and Z sensitivities by approximately 35, 60, and 30, respectively, achieving sensitivities of 20.56 fT/(X), 30.75 fT/(Y) and 20.54 fT/(Z) at 140 and 2 mW. These results demonstrate a structurally simple yet highly effective approach for achieving high uniformity and stability in three‐axis vector magnetic sensing, with strong potential for applications such as spatial magnetic‐field mapping and bio‐magnetic measurement research.
ABSTRACT Miniaturized spin‐exchange relaxation‐free (SERF) atomic magnetometers have become core sensors for detecting biomagnetic fields, including MEG and MCG, due to their ultra‐high sensitivity and high spatiotemporal resolution. Compared to single‐axis magnetometers, triaxial atomic magnetometers are more attractive which can measure comprehensive three‐dimensional magnetic field information. However, traditional triaxial single‐beam or dual‐beam configurations are constrained by limited longitudinal sensitivity or complex optical architectures unsuitable for miniaturized sensors. In this paper, a triaxial dual‐beam magnetic measurement method based on the dynamic evolution of dressed atoms is proposed. The proposed method employs an overlapping pump–probe configuration to simplify the optical sensing architecture while maintaining high magnetic field sensitivity. By utilizing multi‐frequency signal modulation and parallel demodulation, triaxial magnetic vector components are measured simultaneously. Modulation parameters are experimentally optimized based on a systematic analysis of atomic spin dynamics under dual radio‐frequency (RF) fields. Triaxial couplings under various bias magnetic fields are quantitatively analyzed. Experimental validation using a 4 mm vapor cell demonstrates simultaneous triaxial magnetic field measurements, achieving sensitivities of 84.4, 73.2, and 190.7 fT/Hz 1/2 and corresponding bandwidths of 65, 76, and 78 Hz along the x ‐, y ‐, and z ‐axes, respectively.
Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.
Abstract High-sensitivity triaxial magnetic field measurements are crucial in various scientific and industrial applications, with spin-exchange relaxation-free (SERF) atomic magnetometers (AMs) standing out for their exceptional sensitivity. However, conventional methods for achieving triaxial measurements in SERF magnetometers typically involve multiple modulated magnetic fields, which introduce crosstalk challenges in array-based configurations. We propose a static bias magnetic field assisted optical modulation triaxial AM to address this limitation. In this configuration, the detuned circularly polarized light is utilized to achieve synchronous modulation of the fictitious magnetic field and pumping rate while incorporating a static bias magnetic field to generate a transverse projection component. We develop a comprehensive triaxial response model that fully considers the effects of the longitudinal spin polarization deflection. Building upon this model, we derive the relationship between the transverse spin component and the triaxial magnetic field and introduce parameter optimization methods to obtain optimal parameters, thus enabling triaxial measurements of 12 fT Hz −1/2 , 10 fT Hz −1/2 , and 15 fT Hz −1/2 along the x-, y -, and z -axes. Our approach offers significant advantages over existing methods, particularly in minimizing crosstalk and mitigating spin-exchange relaxation introduced by multiple modulated magnetic fields. Moreover, the effective detection of simulated magnetocardiography signals highlights the practical applicability and reliability of the proposed method in real-world scenarios.
The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz1/2{}^{\text {1/2}}1/2for thexxx- andyyy-axes, and a longitudinal sensitivity of 70 fT/Hz1/2{}^{\text {1/2}}1/2for thezzz-axis in a4×4×44\times 4\times 44×4×4mm3 87{}^{\text {3 87}}3 87Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.
This paper investigates the impact of pump-beam spatial shaping on spin-polarization uniformity and light-shiftrelated instability in spin-exchange relaxation-free (SERF) atomic magnetometers. Three representative pump profiles—a single Gaussian beam, a flat-top beam, and a split-beam configuration—are studied by combining a steady-state Bloch model with diffusion and a three-dimensional evaluation of the AC-Stark-shift-induced fictitious magnetic field. Simulations show that the Gaussian beam produces strong center-localized pumping with pronounced transverse/longitudinal gradients, whereas the flat-top beam improves transverse uniformity but decays faster along the propagation direction and tends to maintain a larger absolute light shift. By redistributing optical power into multiple beamlets and leveraging diffusion-driven smoothing, split-beam pumping yields a flatter polarization distribution, achieving the smallest depth-averaged polarization non-uniformity among the three cases, and mitigates the spatial inhomogeneity ofBLSB_{\text{LS}}BLS​by suppressing peak intensity. Experimental validation on a SERF platform is performed using an SLM-generated 2 × 2 beamlet array under identical total incident pump power. Frequency-response measurements atz=0z=0z=0andz=±5 mmz= \pm 5 ~\text{mm}z=±5 mmdemonstrate improved longitudinal response uniformity, and noise-floor measurements in the20−40 Hz20-40 ~\text{Hz}20−40 Hzband exhibit a lower level with weakerzzzdependence, consistent with reduced light-shift-induced noise. The results indicate that split-beam pumping provides an effective and experimentally accessible route to balancing polarization uniformity and light-shift stability in SERF magnetometers.