Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Quantum enhanced metrology in the optical lattice clock

Chi Shu

Published Jan 1, 2023• 0 citations
OpenAlex

Abstract

High-bandwidth, high-stability clocks offer unique chances to study fundamental physics beyond simple metrology. Today, the most stable clocks are optical lattice clocks and they can reach a fractional stability of 3.1 × 10^−18 at 1 s averaging time. Their applications are ranging from the redefinition of the SI time unit, the Second, to the possible detection of gravitational waves in space. The stability of optical lattice clocks is primarily limited by quantum projection noise and Dick noise. In this thesis, I present our effort in creating a platform for studying quantum enhanced metrology and its application towards optical lattice clocks. We demonstrated the laser cooling in an optical cavity with Raman-sideband cooling and achieved average vibration number of n = 0.2. We utilized cavity feedback squeezing to demonstrate unitary spin squeezing on magnetic sub-levels of 171Yb, achieving 6.5 dB quantum projection noise reduction over the standard quantum limit (SQL). With coherent optical state transfer by ultra stable laser pulses, we successfully transferred the spin squeezed state from magnetic sub-levels to the optical transition, and demonstrated quantum enhanced metrology in the optical lattice clock for the first time. We achieved 4.4 dB of metrological gain over the SQL, which corresponds to a reduction of the averaging time by a factor of 2.8 in clock operation. Furthermore, we studied quantum enhanced metrology with time-reversal-based protocols. We performed a signal amplification through time-reversed interaction protocol between the ground state magnetic sublevels of 171Yb, achieving the largest sensitivity improvement beyond SQL in any interferometers to date at 11.8dB. Besides that, we experimentally studied the connection between quantum information scrambling, by measuring out-of-time-order correlators (OTOCs), and quantum metrology, by measuring metrological gain. We found these values to agree with each other, and concluded that the time-reversal quantum metrology can saturate the attainable gain from the quantum information scrambling.

Related papers

Clock Precision beyond the Standard Quantum Limit at 10 − 18 Level

Yutong Yang, Maya Miklos, Yee Ming Tso +3 more

Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1×10^{-18} for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.

arXiv:2505.04538•Physical Review Letters•Nov 7, 2025•21 citations

Quantum Metrology and Many-Body Physics: Pushing the Frontier of the Optical Lattice Clock

Michael J. Martin

Neutral atom optical standards require the highest levels of laser precision to operate near the limit set by quantum fluctuations. We develop state-of-the-art ultra-stable laser systems to achieve a factor of 10 enhancement in clock measurement precision and additionally demonstrate optical linewidths below 50 mHz. The most stable of these lasers reaches its thermal noise floor of 1 × 10-16 fractional frequency instability, allowing the attainment of near quantum-noise-limited clock operation with single-clock instabilities of 3×10-16 at 1 s. We utilize this high level of spectral resolution to operate a 87Sr optical lattice clock in a regime in which quantum collisions play a dominant role in the dynamics, enabling the study of quantum many-body physics. With a fractional level of precision of near 1 × 10-16 at 1 s, we clearly resolve the signatures of many-body interactions. We find that the complicated interplay between the p wave-dominated elastic and inelastic interaction processes between lattice-trapped atoms leads to severe lineshape distortion, shifts, and loss of Ramsey fringe contrast. We additionally explore the theoretical prediction that these many-body interactions will modify the quantum fluctuations of the system and we find that in certain parameter regimes the quantum noise distribution exhibits a quadrature dependence. We further present technological advancements that will permit ultra-stable lasers to operate with reduced thermal noise, leading to a potential gain of an additional factor of 10 in stability. This indicates that laser fractional frequency instabilities of 1 × 10-17 are within experimental reach, as is a fully-quantum-limited regime of optical clock operation.

•Jan 1, 2013•20 citations

Spin Squeezing-Enhanced Stability in an Optical Lattice Clock Comparison

Maya Miklos, Yee Ming Tso, John Martin Robinson +3 more

We perform a self-synchronous clock comparison between two spin-squeezed ensembles in a strontium optical lattice clock to directly measure 2.0(3) dB of metrological gain beyond quantum projection noise-limited operation, averaging down to the 10 − 17 level.

Quantum 2.0 Conference and Exhibition•Jan 1, 2023•0 citations

Absolute frequency measurement of an 171Yb lattice clock and optical clock comparisons

Benjamin Rauf

The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.

•May 23, 2018•0 citations

Spin-squeezing-enhanced optical lattice clocks with 10 − 19 -level differential frequency stability at the averaging time of 1 s

Deshui Yu, Jia Zhang, Tongyan Xia +3 more

Many-body entangled states allow precision measurement beyond the standard quantum limit. Yet they have not been effectively exploited in optical lattice clocks except for proof-of-principle demonstrations. Under the current experimental conditions, taking into account the lattice perturbation, atom-atom interactions, and local oscillator noise, we theoretically evaluate the performance of spin-squeezing-based shallow-lattice Yb optical clocks. The numerical simulation shows that the stability of differential frequency comparison between two Yb ensembles in squeezed spin states potentially accesses the ${10}^{\ensuremath{-}19}$ level at the averaging time of 1 s. The resultant Wineland parameter may be as low as ${\ensuremath{\xi}}_{\text{W}}^{2}=0.027$, corresponding to a reduction of averaging time by a factor of 37, and is limited by the collision-induced degradation of spin squeezing. The metrological gain provided by spin squeezing opens up new opportunities for precision measurement and fundamental physics.

Physical Review A•Jul 1, 2024•4 citations

Entanglement-enhanced optical atomic clocks

Simone Colombo, Edwin Pedrozo-Peñafiel, Vladan Vuletić

Recent developments in atomic physics have enabled the experimental generation of many-body entangled states to boost the performance of quantum sensors beyond the Standard Quantum Limit (SQL). This limit is imposed by the inherent projection noise of a quantum measurement. In this Perspective article, we describe the commonly used experimental methods to create many-body entangled states to operate quantum sensors beyond the SQL. In particular, we focus on the potential of applying quantum entanglement to state-of-the-art optical atomic clocks. In addition, we present recently developed time-reversal protocols that make use of complex states with high quantum Fisher information without requiring sub-SQL measurement resolution. We discuss the prospects for reaching near-Heisenberg limited quantum metrology based on such protocols.

arXiv:2209.00471•Applied Physics Letters•Nov 21, 2022•37 citations
High-bandwidth, high-stability clocks offer unique chances to study fundamental physics beyond simple metrology. Today, the most stable clocks are optical lattice clocks and they can reach a fractional stability of 3.1 × 10^−18 at 1 s averaging time. Their applications are ranging from the redefinition of the SI time unit, the Second, to the possible detection of gravitational waves in space. The stability of optical lattice clocks is primarily limited by quantum projection noise and Dick noise. In this thesis, I present our effort in creating a platform for studying quantum enhanced metrology and its application towards optical lattice clocks. We demonstrated the laser cooling in an optical cavity with Raman-sideband cooling and achieved average vibration number of n = 0.2. We utilized cavity feedback squeezing to demonstrate unitary spin squeezing on magnetic sub-levels of 171Yb, achieving 6.5 dB quantum projection noise reduction over the standard quantum limit (SQL). With coherent optical state transfer by ultra stable laser pulses, we successfully transferred the spin squeezed state from magnetic sub-levels to the optical transition, and demonstrated quantum enhanced metrology in the optical lattice clock for the first time. We achieved 4.4 dB of metrological gain over the SQL, which corresponds to a reduction of the averaging time by a factor of 2.8 in clock operation. Furthermore, we studied quantum enhanced metrology with time-reversal-based protocols. We performed a signal amplification through time-reversed interaction protocol between the ground state magnetic sublevels of 171Yb, achieving the largest sensitivity improvement beyond SQL in any interferometers to date at 11.8dB. Besides that, we experimentally studied the connection between quantum information scrambling, by measuring out-of-time-order correlators (OTOCs), and quantum metrology, by measuring metrological gain. We found these values to agree with each other, and concluded that the time-reversal quantum metrology can saturate the attainable gain from the quantum information scrambling.
Optical atomic clocks with unrivaled precision and accuracy have advanced the frontier of precision measurement science and opened new avenues for exploring fundamental physics. A fundamental limitation on clock precision is the standard quantum limit (SQL), which stems from the uncorrelated projection noise of each atom. State-of-the-art optical lattice clocks interrogate large ensembles to minimize the SQL, but density-dependent frequency shifts pose challenges to scaling the atom number. The SQL can be surpassed, however, by leveraging entanglement, though it remains an open problem to achieve quantum advantage from spin squeezing at state-of-the-art stability levels. Here, we demonstrate clock performance beyond the SQL, achieving a fractional frequency precision of 1.1×10^{-18} for a single spin-squeezed clock. With cavity-based quantum nondemolition measurements, we prepare two spin-squeezed ensembles of ∼30 000 strontium atoms confined in a two-dimensional optical lattice. A synchronous clock comparison with an interrogation time of 61 ms achieves a metrological improvement of 2.0(2) dB beyond the SQL, after correcting for state preparation and measurement errors. These results establish the most precise entanglement-enhanced clock to date and offer a powerful platform for exploring the interplay of gravity and quantum entanglement.
Neutral atom optical standards require the highest levels of laser precision to operate near the limit set by quantum fluctuations. We develop state-of-the-art ultra-stable laser systems to achieve a factor of 10 enhancement in clock measurement precision and additionally demonstrate optical linewidths below 50 mHz. The most stable of these lasers reaches its thermal noise floor of 1 × 10-16 fractional frequency instability, allowing the attainment of near quantum-noise-limited clock operation with single-clock instabilities of 3×10-16 at 1 s. We utilize this high level of spectral resolution to operate a 87Sr optical lattice clock in a regime in which quantum collisions play a dominant role in the dynamics, enabling the study of quantum many-body physics. With a fractional level of precision of near 1 × 10-16 at 1 s, we clearly resolve the signatures of many-body interactions. We find that the complicated interplay between the p wave-dominated elastic and inelastic interaction processes between lattice-trapped atoms leads to severe lineshape distortion, shifts, and loss of Ramsey fringe contrast. We additionally explore the theoretical prediction that these many-body interactions will modify the quantum fluctuations of the system and we find that in certain parameter regimes the quantum noise distribution exhibits a quadrature dependence. We further present technological advancements that will permit ultra-stable lasers to operate with reduced thermal noise, leading to a potential gain of an additional factor of 10 in stability. This indicates that laser fractional frequency instabilities of 1 × 10-17 are within experimental reach, as is a fully-quantum-limited regime of optical clock operation.
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
Many-body entangled states allow precision measurement beyond the standard quantum limit. Yet they have not been effectively exploited in optical lattice clocks except for proof-of-principle demonstrations. Under the current experimental conditions, taking into account the lattice perturbation, atom-atom interactions, and local oscillator noise, we theoretically evaluate the performance of spin-squeezing-based shallow-lattice Yb optical clocks. The numerical simulation shows that the stability of differential frequency comparison between two Yb ensembles in squeezed spin states potentially accesses the ${10}^{\ensuremath{-}19}$ level at the averaging time of 1 s. The resultant Wineland parameter may be as low as ${\ensuremath{\xi}}_{\text{W}}^{2}=0.027$, corresponding to a reduction of averaging time by a factor of 37, and is limited by the collision-induced degradation of spin squeezing. The metrological gain provided by spin squeezing opens up new opportunities for precision measurement and fundamental physics.
Recent developments in atomic physics have enabled the experimental generation of many-body entangled states to boost the performance of quantum sensors beyond the Standard Quantum Limit (SQL). This limit is imposed by the inherent projection noise of a quantum measurement. In this Perspective article, we describe the commonly used experimental methods to create many-body entangled states to operate quantum sensors beyond the SQL. In particular, we focus on the potential of applying quantum entanglement to state-of-the-art optical atomic clocks. In addition, we present recently developed time-reversal protocols that make use of complex states with high quantum Fisher information without requiring sub-SQL measurement resolution. We discuss the prospects for reaching near-Heisenberg limited quantum metrology based on such protocols.