Neutral atom optical standards require the highest levels of laser precision to operate near the limit set by quantum fluctuations. We develop state-of-the-art ultra-stable laser systems to achieve a factor of 10 enhancement in clock measurement precision and additionally demonstrate optical linewidths below 50 mHz. The most stable of these lasers reaches its thermal noise floor of 1 × 10-16 fractional frequency instability, allowing the attainment of near quantum-noise-limited clock operation with single-clock instabilities of 3×10-16 at 1 s. We utilize this high level of spectral resolution to operate a 87Sr optical lattice clock in a regime in which quantum collisions play a dominant role in the dynamics, enabling the study of quantum many-body physics. With a fractional level of precision of near 1 × 10-16 at 1 s, we clearly resolve the signatures of many-body interactions. We find that the complicated interplay between the p wave-dominated elastic and inelastic interaction processes between lattice-trapped atoms leads to severe lineshape distortion, shifts, and loss of Ramsey fringe contrast. We additionally explore the theoretical prediction that these many-body interactions will modify the quantum fluctuations of the system and we find that in certain parameter regimes the quantum noise distribution exhibits a quadrature dependence. We further present technological advancements that will permit ultra-stable lasers to operate with reduced thermal noise, leading to a potential gain of an additional factor of 10 in stability. This indicates that laser fractional frequency instabilities of 1 × 10-17 are within experimental reach, as is a fully-quantum-limited regime of optical clock operation.
Neutral atom optical standards require the highest levels of laser precision to operate near the limit set by quantum fluctuations. We develop state-of-the-art ultra-stable laser systems to achieve a factor of 10 enhancement in clock measurement precision and additionally demonstrate optical linewidths below 50 mHz. The most stable of these lasers reaches its thermal noise floor of 1 × 10-16 fractional frequency instability, allowing the attainment of near quantum-noise-limited clock operation with single-clock instabilities of 3×10-16 at 1 s. We utilize this high level of spectral resolution to operate a 87Sr optical lattice clock in a regime in which quantum collisions play a dominant role in the dynamics, enabling the study of quantum many-body physics. With a fractional level of precision of near 1 × 10-16 at 1 s, we clearly resolve the signatures of many-body interactions. We find that the complicated interplay between the p wave-dominated elastic and inelastic interaction processes between lattice-trapped atoms leads to severe lineshape distortion, shifts, and loss of Ramsey fringe contrast. We additionally explore the theoretical prediction that these many-body interactions will modify the quantum fluctuations of the system and we find that in certain parameter regimes the quantum noise distribution exhibits a quadrature dependence. We further present technological advancements that will permit ultra-stable lasers to operate with reduced thermal noise, leading to a potential gain of an additional factor of 10 in stability. This indicates that laser fractional frequency instabilities of 1 × 10-17 are within experimental reach, as is a fully-quantum-limited regime of optical clock operation.
High-bandwidth, high-stability clocks offer unique chances to study fundamental physics beyond simple metrology. Today, the most stable clocks are optical lattice clocks and they can reach a fractional stability of 3.1 × 10^−18 at 1 s averaging time. Their applications are ranging from the redefinition of the SI time unit, the Second, to the possible detection of gravitational waves in space. The stability of optical lattice clocks is primarily limited by quantum projection noise and Dick noise. In this thesis, I present our effort in creating a platform for studying quantum enhanced metrology and its application towards optical lattice clocks. We demonstrated the laser cooling in an optical cavity with Raman-sideband cooling and achieved average vibration number of n = 0.2. We utilized cavity feedback squeezing to demonstrate unitary spin squeezing on magnetic sub-levels of 171Yb, achieving 6.5 dB quantum projection noise reduction over the standard quantum limit (SQL). With coherent optical state transfer by ultra stable laser pulses, we successfully transferred the spin squeezed state from magnetic sub-levels to the optical transition, and demonstrated quantum enhanced metrology in the optical lattice clock for the first time. We achieved 4.4 dB of metrological gain over the SQL, which corresponds to a reduction of the averaging time by a factor of 2.8 in clock operation. Furthermore, we studied quantum enhanced metrology with time-reversal-based protocols. We performed a signal amplification through time-reversed interaction protocol between the ground state magnetic sublevels of 171Yb, achieving the largest sensitivity improvement beyond SQL in any interferometers to date at 11.8dB. Besides that, we experimentally studied the connection between quantum information scrambling, by measuring out-of-time-order correlators (OTOCs), and quantum metrology, by measuring metrological gain. We found these values to agree with each other, and concluded that the time-reversal quantum metrology can saturate the attainable gain from the quantum information scrambling.
Many-particle optical lattice clocks have the potential for unprecedented measurement precision and stability due to their low quantum projection noise. However, this potential has so far never been realized because clock stability has been limited by frequency noise of optical local oscillators. By synchronously probing two 87Sr lattice systems using a laser with a thermal noise floor of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}15}$, we remove classically correlated laser noise from the intercomparison, but this does not demonstrate independent clock performance. With an improved optical oscillator that has a $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}16}$ thermal noise floor, we demonstrate an order of magnitude improvement over the best reported stability of any independent clock, achieving a fractional instability of $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ in 1000 s of averaging time for synchronous or asynchronous comparisons. This result is within a factor of 2 of the combined quantum projection noise limit for a 160 ms probe time with $\ensuremath{\sim}{10}^{3}$ atoms in each clock. We further demonstrate that even at this high precision, the overall systematic uncertainty of our clock is not limited by atomic interactions. For the second Sr clock, which has a cavity-enhanced lattice, the atomic-density-dependent frequency shift is evaluated to be $\ensuremath{-}3.11\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}17}$ with an uncertainty of $8.2\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$.
Optical lattice clocks demonstrate advantages in metrology and frontier physics because of their high stability.Here, we present approaches to enhancing the stability by decoupling the noise related to the short-term and long-term stability.For the short-term stability, we optimize the clock laser by decoupling the frequency noise, and optimize each noise contribution individually until it is below the thermal noise limit.For the long-term stability, we introduce a method to decouple the instability caused by systematic effects.Having identified that the collision frequency shift was the main limiting factor in our systems, we thus optimized the atom number fluctuations in optical lattices.Through targeted optimization, we achieve a synchronous comparison of two clocks with an average stability of 3.2 × 10 -16 = τ p and a long-term stability of 2.4 × 10 -18 at 8000 s.This work provides an analytical framework for enhancing optical clock stability.
Interactions between atoms and lasers provide the potential for unprecedented control of quantum states. Fulfilling this potential requires detailed knowledge of frequency noise in optical oscillators with state-of-the-art stability. We demonstrate a technique that precisely measures the noise spectrum of an ultrastable laser using optical lattice-trapped 87Sr atoms as a quantum projection noise-limited reference. We determine the laser noise spectrum from near dc to 100 Hz via the measured fluctuations in atomic excitation, guided by a simple and robust theory model. The noise spectrum yields a 26(4) mHz linewidth at a central frequency of 429 THz, corresponding to an optical quality factor of 1.6×10(16). This approach improves upon optical heterodyne beats between two similar laser systems by providing information unique to a single laser and complements the traditionally used Allan deviation which evaluates laser performance at relatively long time scales. We use this technique to verify the reduction of resonant noise in our ultrastable laser via feedback from an optical heterodyne beat. Finally, we show that knowledge of our laser's spectrum allows us to accurately predict the laser-limited stability for optical atomic clocks.
Frequency metrology underpins precise measurements. At the forefront of this field are optical clocks which can perform measurements that are accurate to more digits than those in the number representing seconds elapsed from the beginning of the universe. Frequency estimation errors in the operation of optical clocks lead to frequency instability, prohibiting them from reaching high accuracies on short to medium time scales, and limiting access to interesting measurements of the atomic environment and exotic external perturbations such as gravity fields or fields of fundamentally new physical origins. Optical lattice traps are typically employed in state-of-the-art optical clocks to suppress Doppler effects. By carefully tuning the optical lattice to the magic wavelength, unwanted Stark shifts can be suppressed significantly, allowing operation with thousands of atoms and minimising the fundamental source of frequency estimation errors, namely the quantum projection noise, to around 3 × 10−17 at 1 s. In this thesis, the status of the two Strontium optical lattice clocks at NPL, Sr1 and Sr2, is presented going over a few interesting measurement campaigns from the past years involving Sr1 and the latest experimental efforts to re-enable operation of Sr2. A model of clock stability is developed by incorporating known and new frameworks to characterise the relation between the operating parameters of optical clocks and their performance, with relevance to the NPL lattice clocks and beyond. In particular, a method is identified for addressing the main technical noise for optical lattice clocks, the Dick effect, which typically has a magnitude of 10−16 at 1 s and prevents optical lattice clocks from reaching the quantum projection noise level. By taking advantage of dynamical decoupling we can engineer an optimised duty cycle with benefits in general for systems limited by the optical coherence of the clock laser. Moreover, a study of other noise sources in the NPL lattice clocks is conducted using synchronous measurements between Sr1 and Sr2, revealing a large contribution from linear Zeeman shifts, also at the 10−16 level, and a plan to tackle them is detailed. A hybrid clock architecture is discussed showing how optical lattice clocks can improve the optical coherence of ion clocks thanks to their higher servo rate, and a preliminary experimental demonstration is reported. Finally, a new type of spectroscopy is presented which completely avoids aliasing of linear Zeeman shifts by simultaneously driving transitions with opposite Zeeman sensitivities. Such a technique also enables the continuous interrogation of atoms, a crucial missing component in the Dick-free conveyor belt lattice clock concept heralded as the next standard of stable optical clocks.
Quantum technologies are nowadays emerging as enabling tools for practical applications, such as quantum sensing, quantum computing and quantum metrology. Lasers play a central role in many of these technological platforms, e.g. for atomic clocks, ion-based or neutral atom-based quantum computers or atom interferometers. Here we present a complete laser system to cool, trap and control strontium atoms in an optical lattice or in tweezer arrays. A sub-Hz linewidth master laser, locked to a high-finesse optical cavity provides the frequency reference for an ultra-low noise comb. The rack-mounted laser system consists of all cooling, repumping, and clock lasers stabilized to the optical frequency comb. Each of the involved laser frequencies can therefore be tuned and mapped in the frequency domain with a high degree of stability. The system is controlled via a software interface, allowing to operate the cold-atom-based physics package autonomously. The system is tailored for the operation of 88Sr or 87Sr optical lattice clocks, or for quantum computing applications, but other sub-Hz lasers could be obtained by phase locking additional clock laser frequencies to the ultra-stable comb, enabling convenient and accurate optical frequency ratio measurements. The laser system architecture and the relevant characterization measurements will be presented, proposing some user-cases such as quantum computing and atom interferometry on strontium atoms. This represents a technological leap for quantum optics, allowing to explore further applications of quantum sensors outside a traditional lab.