Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Simulation study on the impact of microwave pulses on performance of ensemble nitrogen-vacancy centers

Xu-Bo 旭博 Liao 廖, Yi Zhang, Qiyuan Jiang, Bing-Feng Sun, Sheng-Bing Shi, Shiyu Guan, Yuxiao Wang, Zhong-Qi 中奇 Tan 谭, Jie Hong Yuan

Published Nov 27, 2025• 0 citations
Publisher

Abstract

Abstract This study is conducted to establish a reliable simulation model for investigating the impact of microwave pulses on the performance of an ensemble nitrogen-vacancy (NV) center system, thereby providing a basis for optimizing microwave parameters and enhancing quantum sensing performance. The simulation of ensemble NV centers is realized through the design of “Single NV Center Module” + “Ensemble Control Module”. Verified by optically detected magnetic resonance (ODMR), Ramsey, and Hahn echo experiments, the program can accurately reproduce the core characteristics of the experiments, confirming the reliability of the model. Using this model to study the influence of microwave spatial inhomogeneity on system performance, it was found that when θ (the range of microwave axial distribution) is 90°, the sensitivity of the Hahn echo decreases by 3.6 times, and when the amplitude gradient is 50 μT/mm, the sensitivity decreases by 1.8 times, providing quantitative support for optimizing microwave parameters.

DOI
10.1088/1674-1056/ae24e9

Related papers

Compact and portable pulsed measurement module using diamond NV centers

Hiroshige Deguchi, Tsukasa Hayashi, Hiroya Saito +6 more

Abstract We developed a compact, portable quantum sensor module for pulsed measurements using diamond nitrogen-vacancy (NV) centers, an excitation laser diode of 3 mW and a microwave source of 15 dBm. This module allowed the evaluation of ensemble diamond NV centers for measuring magnetic fields by continuous wave— optically detected magnetic resonance (ODMR), Rabi oscillation, pulsed ODMR, Ramsey measurement and spin-echo measurement. The sensitivity through pulsed measurements reached 40 nT/ Hz at 1 Hz, which achieved higher sensitivity by one order, especially at a frequency around 1 Hz compared with previously reported compact modules using diamond NV centers.

Japanese Journal of Applied Physics•Jun 27, 2025•2 citations

Demonstration of highly sensitive wideband microwave sensing using ensemble nitrogen-vacancy centers

Kensuke Ogawa, Shunsuke Nishimura, Kento Sasaki +1 more

Microwave magnetometry is essential for the advancement of microwave technologies. We demonstrate a broadband microwave sensing protocol using the AC Zeeman effect with ensemble nitrogen-vacancy (NV) centers in diamond. A widefield microscope can visualize the frequency characteristics of the microwave resonator and the spatial distribution of off-resonant microwave amplitude. Furthermore, by combining this method with dynamical decoupling, we achieve the microwave amplitude sensitivity of 5.2 μT/Hz, which is 7.7 times better than 40.2 μT/Hz obtained using the protocol in previous research over a sensing volume of 2.77 μm×2.77 μm×30 nm. Our achievement is a concrete step in adapting ensemble NV centers for wideband and widefield microwave imaging.

arXiv:2311.15196•Applied Physics Letters•Nov 20, 2023•7 citations

Triple-tone microwave control for sensitivity optimization in compact ensemble nitrogen-vacancy magnetometers

Ankita Chakravarty, Romain Ruhlmann, Vincent Halde +4 more

Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common 14 N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements and use the model to explore triple-tone versus single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.

arXiv:2510.00913•Journal of the Optical Society of America B•Jan 8, 2026•0 citations

Tunable double split-ring resonator for quantum sensing using nitrogen-vacancy centers in diamond

Yan Yang, Qin Wu, Yangpeng Wang +5 more

For quantum sensing based on nitrogen-vacancies (NV) ensembles, microwave antennas can couple the microwave field to the NV center, which leads it to becoming the core of spin manipulation and can directly affect the sensitivity of quantum sensing. The double split-ring resonator is a widely used microwave device for NV ensembles due to the advantages of high radiation efficiency and uniform magnetic field in millimeter-scale areas. But the bandwidth (30 MHz) is quite narrow which limits the application in quantum sensing with NV ensembles. Here, we experimentally achieve continuous tuning of the resonant frequency of the double split-ring resonator by changing the copper sheet position on the edge of the outer ring. The frequency tuning range can reach 80 MHz, up to 2-3 times the bandwidth, which can cover the transition of the electron spin under different magnetic field conditions. The performance of the tunable antenna in the quantum operation of NV centers is verified by optically detected magnetic resonance and Rabi oscillation. This tunable antenna is promising in the fabrication of integrated and arrayed quantum sensors based on NV ensembles.

Optics Continuum•May 16, 2023•11 citations

Uniform microwave field formation for control of ensembles of negatively charged nitrogen vacancy in diamond

Oleg Rezinkin, Marina Rezinkina, Takuya Kitamura +2 more

The homogeneity of the microwave magnetic field is essential in controlling a large volume of ensemble spins, for example, in the case of sensitive magnetometry with nitrogen-vacancy (NV) centers in diamond. This is particularly important for pulsed measurement, where the fidelity of control pulses plays a crucial role in its sensitivity. So far, several magnetic field-forming systems have been proposed, but no detailed comparison has been made. Here, we numerically study the homogeneity of five different systems, including a planar antenna, a dielectric resonator, a cylindrical inductor, a barrel-shaped coil, and a nested barrel-shaped coil. The results of the simulation allowed us to optimize the design parameters of the barrel-shaped field-forming system, which led to significantly improved magnetic field uniformity. To measure this effect, we experimentally compared the homogeneity of a field-forming system having a barrel shape with that of a planar field-forming system by measuring Rabi oscillations of an ensemble of NV centers with them. Significant improvements in inhomogeneity were confirmed in the barrel-shaped coil.

quant-pharXiv:2605.13267•May 14, 2026

Microwave-induced fluorescence of ensemble NV centers using PCB-based RF devices for quantum sensing

Atefe Safinezhad, Aashutosh Kumar, Richard Al Hadi +1 more

Nitrogen-vacancy (NV) centers in diamond are solid-state quantum sensors that operate at room temperature and allow optical readout of spin states through optically detected magnetic resonance (ODMR). Reliable ODMR measurements need controlled microwave excitation to manipulate NV spin states and modulate their fluorescence. In this paper, we report on ensemble NV centers’ interaction with microwave fields transmitted by printed-circuit-board (PCB) radio-frequency (RF) devices. Two microwave structures, a coplanar waveguide transmission line (CPW-TL) and a single-finger interdigitated capacitor (IDC), are designed and impedance-matched at the NV zero-field splitting frequency. Nanodiamond solutions containing NV ensembles are deposited as few-microliter droplets onto the PCB devices and dried, forming localized NV layers on the RF structures. Two-dimensional fluorescence scans are used to link spatial changes in NV fluorescence to the microwave field distributions created by each device geometry. CPW-TLs enable interaction over extended regions along the transmission line, while IDCs produce localized excitation near the capacitive gaps.

Photonics for Quantum (PfQ)•Jul 22, 2026•0 citations
Abstract This study is conducted to establish a reliable simulation model for investigating the impact of microwave pulses on the performance of an ensemble nitrogen-vacancy (NV) center system, thereby providing a basis for optimizing microwave parameters and enhancing quantum sensing performance. The simulation of ensemble NV centers is realized through the design of “Single NV Center Module” + “Ensemble Control Module”. Verified by optically detected magnetic resonance (ODMR), Ramsey, and Hahn echo experiments, the program can accurately reproduce the core characteristics of the experiments, confirming the reliability of the model. Using this model to study the influence of microwave spatial inhomogeneity on system performance, it was found that when θ (the range of microwave axial distribution) is 90°, the sensitivity of the Hahn echo decreases by 3.6 times, and when the amplitude gradient is 50 μT/mm, the sensitivity decreases by 1.8 times, providing quantitative support for optimizing microwave parameters.
Abstract We developed a compact, portable quantum sensor module for pulsed measurements using diamond nitrogen-vacancy (NV) centers, an excitation laser diode of 3 mW and a microwave source of 15 dBm. This module allowed the evaluation of ensemble diamond NV centers for measuring magnetic fields by continuous wave— optically detected magnetic resonance (ODMR), Rabi oscillation, pulsed ODMR, Ramsey measurement and spin-echo measurement. The sensitivity through pulsed measurements reached 40 nT/ Hz at 1 Hz, which achieved higher sensitivity by one order, especially at a frequency around 1 Hz compared with previously reported compact modules using diamond NV centers.
Microwave magnetometry is essential for the advancement of microwave technologies. We demonstrate a broadband microwave sensing protocol using the AC Zeeman effect with ensemble nitrogen-vacancy (NV) centers in diamond. A widefield microscope can visualize the frequency characteristics of the microwave resonator and the spatial distribution of off-resonant microwave amplitude. Furthermore, by combining this method with dynamical decoupling, we achieve the microwave amplitude sensitivity of 5.2 μT/Hz, which is 7.7 times better than 40.2 μT/Hz obtained using the protocol in previous research over a sensing volume of 2.77 μm×2.77 μm×30 nm. Our achievement is a concrete step in adapting ensemble NV centers for wideband and widefield microwave imaging.
Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common 14 N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements and use the model to explore triple-tone versus single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.
For quantum sensing based on nitrogen-vacancies (NV) ensembles, microwave antennas can couple the microwave field to the NV center, which leads it to becoming the core of spin manipulation and can directly affect the sensitivity of quantum sensing. The double split-ring resonator is a widely used microwave device for NV ensembles due to the advantages of high radiation efficiency and uniform magnetic field in millimeter-scale areas. But the bandwidth (30 MHz) is quite narrow which limits the application in quantum sensing with NV ensembles. Here, we experimentally achieve continuous tuning of the resonant frequency of the double split-ring resonator by changing the copper sheet position on the edge of the outer ring. The frequency tuning range can reach 80 MHz, up to 2-3 times the bandwidth, which can cover the transition of the electron spin under different magnetic field conditions. The performance of the tunable antenna in the quantum operation of NV centers is verified by optically detected magnetic resonance and Rabi oscillation. This tunable antenna is promising in the fabrication of integrated and arrayed quantum sensors based on NV ensembles.
The homogeneity of the microwave magnetic field is essential in controlling a large volume of ensemble spins, for example, in the case of sensitive magnetometry with nitrogen-vacancy (NV) centers in diamond. This is particularly important for pulsed measurement, where the fidelity of control pulses plays a crucial role in its sensitivity. So far, several magnetic field-forming systems have been proposed, but no detailed comparison has been made. Here, we numerically study the homogeneity of five different systems, including a planar antenna, a dielectric resonator, a cylindrical inductor, a barrel-shaped coil, and a nested barrel-shaped coil. The results of the simulation allowed us to optimize the design parameters of the barrel-shaped field-forming system, which led to significantly improved magnetic field uniformity. To measure this effect, we experimentally compared the homogeneity of a field-forming system having a barrel shape with that of a planar field-forming system by measuring Rabi oscillations of an ensemble of NV centers with them. Significant improvements in inhomogeneity were confirmed in the barrel-shaped coil.
Nitrogen-vacancy (NV) centers in diamond are solid-state quantum sensors that operate at room temperature and allow optical readout of spin states through optically detected magnetic resonance (ODMR). Reliable ODMR measurements need controlled microwave excitation to manipulate NV spin states and modulate their fluorescence. In this paper, we report on ensemble NV centers’ interaction with microwave fields transmitted by printed-circuit-board (PCB) radio-frequency (RF) devices. Two microwave structures, a coplanar waveguide transmission line (CPW-TL) and a single-finger interdigitated capacitor (IDC), are designed and impedance-matched at the NV zero-field splitting frequency. Nanodiamond solutions containing NV ensembles are deposited as few-microliter droplets onto the PCB devices and dried, forming localized NV layers on the RF structures. Two-dimensional fluorescence scans are used to link spatial changes in NV fluorescence to the microwave field distributions created by each device geometry. CPW-TLs enable interaction over extended regions along the transmission line, while IDCs produce localized excitation near the capacitive gaps.