Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common 14 N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements and use the model to explore triple-tone versus single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.
Ensembles of nitrogen-vacancy (NV) centers in diamond are a well-established platform for quantum magnetometry under ambient conditions. One challenge arises from the hyperfine structure of the NV, which, for the common 14 N isotope, results in a threefold reduction of contrast and thus sensitivity. By addressing each of the NV hyperfine transitions individually, triple-tone microwave (MW) control can mitigate this sensitivity loss. Here, we experimentally and theoretically investigate the regimes in which triple-tone excitation offers an advantage over standard single-tone MW control for two DC magnetometry protocols: pulsed optically detected magnetic resonance (ODMR) and Ramsey interferometry. We validate a master equation model of the NV dynamics against ensemble NV measurements and use the model to explore triple-tone versus single-tone sensitivity for different MW powers and NV dephasing rates. For pulsed ODMR, triple-tone driving improves sensitivity by up to a factor of three in the low dephasing regime, with diminishing gains when dephasing rates approach the hyperfine splitting. In contrast, for Ramsey interferometry, triple-tone excitation only improves sensitivity if MW power is limited. Our results delineate the operating regimes where triple-tone control provides a practical strategy for enhancing NV ensemble magnetometry in portable and power-limited sensors.
Abstract Negatively charged nitrogen-vacancy (NV) centers in diamonds are commonly used in quantum magnetometry. However, the potential of this approach is often limited by the inhomogeneity of the driving field. In this study, we explore the potential of closed-loop quantum optimal control to improve DC Ramsey magnetometry with NV-ensembles suffering from inhomogeneous microwave (MW) fields and MW power limitations. We demonstrate an improvement of the optically detected Ramsey contrast up to a factor of 3.13. This enables noticeable power savings for miniaturized devices without loss in magnetometry performance. Additionally, we show a recovery of 86.3% of the Ramsey contrast in presence of a five times less homogeneous MW field compared to the homogeneous field of a MW Helmholtz coil pair.
Shallow nitrogen-vacancy (NV) centers are promising candidates for high-precision sensing applications; these defects, when positioned a few nanometers below the surface, provide an atomic-scale resolution along with substantial sensitivity. However, the dangling bonds and impurities on the diamond surface result in a complex environment which reduces the sensitivity and is unique to each shallow NV center. To avoid the environment's detrimental effect, we apply feedback-based quantum optimal control. We first show how a direct search can improve the initialization and readout process. In a second step, we optimize microwave pulses for pulsed optically detected magnetic resonance (ODMR) and Ramsey measurements. Throughout the sensitivity optimizations, we focus on robustness against errors in the control field amplitude. This feature not only protects the protocols' sensitivity from drifts but also enlarges the sensing volume. The resulting ODMR measurements produce sensitivities below $1\phantom{\rule{0.28em}{0ex}}\ensuremath{\mu}\mathrm{T}$ ${\mathrm{Hz}}^{\ensuremath{-}\frac{1}{2}}$ for an 83% decrease in control power, increasing the robustness by approximately one third. The optimized Ramsey measurements produce sensitivities below 100 nT ${\mathrm{Hz}}^{\ensuremath{-}\frac{1}{2}}$ giving a twofold sensitivity improvement. Being on par with typical sensitivities obtained via single NV magnetometry, the complementing robustness of the presented optimization strategy may provide an advantage for other NV-based applications.
Ensembles of nitrogen-vacancy (NV) centers in diamond are versatile quantum sensors with broad applications in the physical and life sciences. The concentration of neutral substitutional nitrogen ( [ N s 0 ]) strongly influences NV electronic spin coherence times, sensitivity, and optimal sensing strategies. Diamonds with [ N s 0 ] ∼ 1–10 ppm are a focus of recent material engineering efforts, with higher concentrations being favorable for continuous-wave optically detected magnetic resonance (CW-ODMR) and lower concentrations expected to benefit pulsed magnetometry techniques through extended NV spin coherence times and improved sensing duty cycles. In this work, we synthesize and characterize low- [ N s 0 ] ( ∼ 0.8 ppm), NV-enriched diamond material, engineered through low-strain chemical vapor deposition (CVD) growth on high-quality substrates, 12 C isotopic purification, and controlled electron irradiation and annealing. Our results demonstrate good strain homogeneity in diamonds grown on CVD substrates and spin-bath-limited NV dephasing times. By measuring NV spin and charge properties across a wide range of optical NV excitation intensity, we provide direct comparisons of photon-shot-noise-limited magnetic field sensitivity between the current low- [ N s 0 ] and previously studied higher- [ N s 0 ] ( ∼ 14 ppm) NV-diamond sensors. We show that low- [ N s 0 ] diamond can outperform higher- [ N s 0 ] diamond at moderate and low optical NV excitation intensity. Our results provide practical benchmarks and guidance for selecting NV-diamond sensors tailored to specific experimental constraints and sensing requirements.
Quantum sensing with solid-state spins offers the promise of high spatial resolution, bandwidth, and dynamic range at sensitivities comparable to more mature quantum sensing technologies, such as atomic vapor cells and superconducting devices. However, despite comparable theoretical sensitivity limits, the performance of bulk solid-state quantum sensors has so far lagged behind these more mature alternatives. A recent review [Barry et al., Rev. Mod. Phys. 92, 015004 (2020)] suggests several paths to improve performance of magnetometers employing nitrogen-vacancy defects in diamond, the most-studied solid-state quantum sensing platform. Implementing several suggested techniques, we demonstrate the most sensitive nitrogen-vacancy-based bulk magnetometer reported to date. Our approach combines tailored diamond growth to achieve low strain and long intrinsic dephasing times, the use of double-quantum Ramsey and Hahn-echo magnetometry sequences for broadband and narrowband magnetometry, respectively, and P1 driving to further extend dephasing time. Notably, the device does not include a flux concentrator, preserving the fixed response of the nitrogen vacancies to magnetic field. The magnetometer realizes a minimum sensitivity of 460fTs1/2 in a broadband dc-sensitive mode and 210fTs1/2 in a narrowband ac mode. We describe the experimental setup in detail and highlight potential paths for future improvement.
The nitrogen-vacancy (NV) center in diamond is a leading solid-state platform for room-temperature quantum magnetometry owing to its long spin coherence times, optical spin initialization and readout, and high sensitivity to magnetic, electric, and thermal perturbations. As NV-based optically detected magnetic resonance (ODMR) systems transition from controlled laboratory environments toward portable and field-deployable sensors, a detailed understanding of realistic noise sources and experimental imperfections becomes essential for optimizing performance and sensitivity. In this work, we present a comprehensive simulation framework, i.e., a digital twin, for continuous-wave wide-field ODMR in NV-center ensembles. The model is built upon a physically consistent seven-level description of the NV center and incorporates a broad range of experimentally relevant noise and imperfection mechanisms as modular, parameterized components. These include laser and microwave amplitude fluctuations, microwave phase noise, uncertainty in the NV gyromagnetic ratio, spin dephasing, temperature-induced shifts of the ground-state zero-field splitting, surface-induced magnetic field perturbations, and photon shot noise. Power broadening and contrast degradation arising from optical and microwave driving are captured self-consistently through linewidth calculations. Also, the spatial inhomogeneity is modeled via a Gaussian laser intensity profile across the sensing region...
Abstract We developed a compact, portable quantum sensor module for pulsed measurements using diamond nitrogen-vacancy (NV) centers, an excitation laser diode of 3 mW and a microwave source of 15 dBm. This module allowed the evaluation of ensemble diamond NV centers for measuring magnetic fields by continuous wave— optically detected magnetic resonance (ODMR), Rabi oscillation, pulsed ODMR, Ramsey measurement and spin-echo measurement. The sensitivity through pulsed measurements reached 40 nT/ Hz at 1 Hz, which achieved higher sensitivity by one order, especially at a frequency around 1 Hz compared with previously reported compact modules using diamond NV centers.