Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Japanese Journal of Applied Physics

Compact and portable pulsed measurement module using diamond NV centers

Hiroshige Deguchi, Tsukasa Hayashi, Hiroya Saito, Yoshiki Nishibayashi, Minori Teramoto, Masanori Fujiwara, Hiroki Morishita, Norikazu Mizuochi, Natsuo Tatsumi

Published Jun 27, 2025• 2 citations
Publisher

Abstract

Abstract We developed a compact, portable quantum sensor module for pulsed measurements using diamond nitrogen-vacancy (NV) centers, an excitation laser diode of 3 mW and a microwave source of 15 dBm. This module allowed the evaluation of ensemble diamond NV centers for measuring magnetic fields by continuous wave— optically detected magnetic resonance (ODMR), Rabi oscillation, pulsed ODMR, Ramsey measurement and spin-echo measurement. The sensitivity through pulsed measurements reached 40 nT/ Hz at 1 Hz, which achieved higher sensitivity by one order, especially at a frequency around 1 Hz compared with previously reported compact modules using diamond NV centers.

DOI
10.35848/1347-4065/ade924

Related papers

Using NV centers in diamond to detect DC to very-low frequency magnetic fields

Valts Krumins, Ivars Krastins, Oskars Rudzitis +3 more

In this work we present a compact and portable tabletop magnetometer that utilizes negatively charged nitrogen-vacancy (NV) centers in diamond. The magnetometer is operated using a dual microwave resonance detection approach in combination with an optically detected magnetic resonance (ODMR) technique (mitigating drifts in results due to changes of the diamond temperature), capable of simultaneously exciting and registering two ODMR transitions. The experimentally measured magnetic field noise-floor is $\approx 2.3~\textrm{nT}\sqrt{\textrm{Hz}}$ while the calculated shot-noise-limited magnetic field sensitivity is $\approx 585~\textrm{pT}\sqrt{\textrm{Hz}}$ when excited with a continuous wave laser at 0.5~W. These results pave the way for realizing a simple set-up magnetometer for precise single axis magnetic field measurements for example for accurate electric current measurements for stabilization purposes and magnetic communication applications.

quant-pharXiv:2512.24273•Dec 31, 2025

Compact quantum sensing device with Nitrogen-Vacancy centers in diamond

Davide Daloiso

This thesis investigates the theoretical foundations, material properties, and experimental realization of quantum sensors based on the Nitrogen-Vacancy (NV) centers in diamond, a solid-state system that combines quantum coherence with room-temperature operability. The first chapter introduces the principles of quantum sensing, outlining the fundamental definitions, operating protocols, and physical processes underlying the quantum measurement paradigm. Emphasis is placed on the quantum sensing Hamiltonian and the distinction between various classes of quantum sensors. The second chapter focuses on diamond as a host material and on the NV center as a quantum defect. The electronic structure, optical transitions, and spin properties of the NV center are analyzed in detail. Several techniques of NV-based magnetometry are presented, including continuouswave and pulsed optically detected magnetic resonance (ODMR). The discussion also addresses coherence times (T1, T2, and T∗2 ) and methods of diamond synthesis together with NV-center generation through irradiation and annealing. Chapter three develops the physical theory describing the NV center. The Hamiltonian formalism includes spin-spin, hyperfine, and quadrupolar interactions, as well as couplings to external magnetic fields. The chapter further introduces the Bloch sphere representation, magnetic resonance phenomena, and models of lightmatter interaction, ranging from the semiclassical to the fully quantum Rabi framework. A seven-level rate-equation model is proposed to capture the spin dynamics and optical cycling processes of the NV center. The fourth chapter reports the experimental results. After describing materials and methods, several ODMR-based vector magnetometry experiments are presented, highlighting different spectral regimes and the dependence of resonance features on the external magnetic field geometry. Additional studies demonstrate temperature sensing and microwave-free magnetometry techniques for mapping magnetic field distributions. Sensitivity analysis and calibration procedures are also discussed.

•Jan 19, 2026•0 citations

Solid-State Quantum Microwave Standard Using Nitrogen-Vacancy Centers in Diamond

Masahiro Yamamoto, Moriyoshi Haruyama, Moto Kinoshita +3 more

Solid-state quantum sensors based on nitrogen-vacancy (NV) centers in diamond offer room-temperature operation, chemical stability, and a wide range of operating environments, and their application to microwave (MW) measurements are anticipated. In this study, we propose a method for quantitative MW field measurements under continuous-wave driving, referred to as the "NV Candle," aimed at realizing a solid-state quantum MW standard. Building on the atomic candle concept developed in atomic vapor systems, this method employs phase modulation of MW and resonance with Rabi oscillations to extract the Rabi frequency in the frequency domain. Experiments using NV centers in diamond demonstrated that the MW magnetic field derived from the NV Candle signals exhibited linearity over a 20 dB dynamic range. This work presents a novel approach to realize a solid-state quantum MW standard with enhanced robustness and practical applicability.

Conference on Precision Electromagnetic Measurements•Sep 1, 2026•0 citations

Compact and portable quantum sensor module using diamond NV centers

Hiroshige Deguchi, Tsukasa Hayashi, Hiroya Saito +6 more

Abstract We developed a compact and portable measuring instrument using diamond NV centers that operates on the USB 3.0 power supply of a laptop computer. Its portability is achieved by the low power consumption of the optics, realized by the diamond corner cube that enhanced the current of the photodiode to 2.1 times higher than that of the planar diamond, and that of the microwave source, reduced by 20 dB, which was realized by a microwave resonator using a λ/4 open stub that strongly magnetically drives the NV center. These results contribute to the social implementation of diamond sensors.

Applied Physics Express•May 23, 2023•15 citations

Implementation of digital filtering detection method for portable highly sensitive quantum diamond magnetometer

Y. MASUYAMA, Takayuki Iwasaki, Mutsuko Hatano +1 more

One of the promising solid-state quantum sensors is nitrogen-vacancy (NV) centers in diamond which can maintain quantum state at room temperature and under atmospheric pressure condition. Further improvement of sensitivity of the sensor is needed to detect the magnetic field from the brain. Noise reduction and simplified system are key techniques especially for the practical use of highly sensitive DC magnetic sensor. In this study, we devised a digital filtering detection method without synchronization between detector and modulator which is a similar noise reduction effect as a lock-in detection technique. We implemented the detection method for the quantum diamond sensor system with the large sensor volume [1]. The Lock-in detection technique is a typical high sensitivity technique for DC magnetic measurement. There are several different implementations of lock-in detection technique for the quantum diamond sensor including microwave modulation, magnetic field modulation, and laser modulation. However, it is a challenging task to obtain high magnetic sensitivity with a compact sensor module because these lock-in detection techniques require a lock-in amplifier or synchronization system. We devised a digital filtering detection method which is an alternative method to the lock-in detection technique. Fluorescence from the NV center is modulated by frequency modulated microwave during optical detected magnetic resonance (ODMR) measurement. The fluorescence is analyzed by digital signal processing which achieves a similar noise reduction effect as a lock-in detection technique. Our method relies on a fact that ODMR converts frequency modulation to amplitude modulation. Thus, our method is applicable not only to the NV center system but also another color center system. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Y. Masuyama et al., Rev. Sci. Instrum. 89, 125007 (2018).

•Jun 4, 2019•0 citations

High bandwidth heterodyne sensing with bulk NV diamond

H. A. M. Taylor, J. P. Duff, L. B. Miller +4 more

Developing high performance portable sensors is of significant importance for both terrestrial and satellite communications, with quantum sensors offering potential advantages in sensitivity and bandwidth. The nitrogen vacancy center in diamond is a popular quantum sensing platform for its relative simplicity and wide range of acceptable operating conditions, but suffers a limited instantaneous bandwidth due to the narrow linewidth of the spin resonance. In this work, we first present a magnetic quantum sensing scheme utilizing heterodyne mixing with strong optical and microwave driving, achieving MHz-scale instantaneous bandwidth with a sensitivity of $548 \; \text{pT/}\sqrt{\text{Hz}}$ in an active diamond volume of $ 2.5\times 10^{-4} \; \text{mm}^3$ with $2 \times 10^{11}$ NV centers. We then demonstrate expansion of the sensing bandwidth by employing a strong magnetic gradient and many individually modulated microwave control fields, expanding the single resonance bandwidth to 48 MHz with a peak sensitivity of $8.5 \; \text{nT/}\sqrt{\text{Hz}}$.

quant-pharXiv:2610.39022•Physical Review Applied•Oct 30, 2026•1 citation
Abstract We developed a compact, portable quantum sensor module for pulsed measurements using diamond nitrogen-vacancy (NV) centers, an excitation laser diode of 3 mW and a microwave source of 15 dBm. This module allowed the evaluation of ensemble diamond NV centers for measuring magnetic fields by continuous wave— optically detected magnetic resonance (ODMR), Rabi oscillation, pulsed ODMR, Ramsey measurement and spin-echo measurement. The sensitivity through pulsed measurements reached 40 nT/ Hz at 1 Hz, which achieved higher sensitivity by one order, especially at a frequency around 1 Hz compared with previously reported compact modules using diamond NV centers.
In this work we present a compact and portable tabletop magnetometer that utilizes negatively charged nitrogen-vacancy (NV) centers in diamond. The magnetometer is operated using a dual microwave resonance detection approach in combination with an optically detected magnetic resonance (ODMR) technique (mitigating drifts in results due to changes of the diamond temperature), capable of simultaneously exciting and registering two ODMR transitions. The experimentally measured magnetic field noise-floor is ≈2.3 nTHz\approx 2.3~\textrm{nT}\sqrt{\textrm{Hz}}≈2.3 nTHz​ while the calculated shot-noise-limited magnetic field sensitivity is ≈585 pTHz\approx 585~\textrm{pT}\sqrt{\textrm{Hz}}≈585 pTHz​ when excited with a continuous wave laser at 0.5~W. These results pave the way for realizing a simple set-up magnetometer for precise single axis magnetic field measurements for example for accurate electric current measurements for stabilization purposes and magnetic communication applications.
This thesis investigates the theoretical foundations, material properties, and experimental realization of quantum sensors based on the Nitrogen-Vacancy (NV) centers in diamond, a solid-state system that combines quantum coherence with room-temperature operability. The first chapter introduces the principles of quantum sensing, outlining the fundamental definitions, operating protocols, and physical processes underlying the quantum measurement paradigm. Emphasis is placed on the quantum sensing Hamiltonian and the distinction between various classes of quantum sensors. The second chapter focuses on diamond as a host material and on the NV center as a quantum defect. The electronic structure, optical transitions, and spin properties of the NV center are analyzed in detail. Several techniques of NV-based magnetometry are presented, including continuouswave and pulsed optically detected magnetic resonance (ODMR). The discussion also addresses coherence times (T1, T2, and T∗2 ) and methods of diamond synthesis together with NV-center generation through irradiation and annealing. Chapter three develops the physical theory describing the NV center. The Hamiltonian formalism includes spin-spin, hyperfine, and quadrupolar interactions, as well as couplings to external magnetic fields. The chapter further introduces the Bloch sphere representation, magnetic resonance phenomena, and models of lightmatter interaction, ranging from the semiclassical to the fully quantum Rabi framework. A seven-level rate-equation model is proposed to capture the spin dynamics and optical cycling processes of the NV center. The fourth chapter reports the experimental results. After describing materials and methods, several ODMR-based vector magnetometry experiments are presented, highlighting different spectral regimes and the dependence of resonance features on the external magnetic field geometry. Additional studies demonstrate temperature sensing and microwave-free magnetometry techniques for mapping magnetic field distributions. Sensitivity analysis and calibration procedures are also discussed.
Solid-state quantum sensors based on nitrogen-vacancy (NV) centers in diamond offer room-temperature operation, chemical stability, and a wide range of operating environments, and their application to microwave (MW) measurements are anticipated. In this study, we propose a method for quantitative MW field measurements under continuous-wave driving, referred to as the "NV Candle," aimed at realizing a solid-state quantum MW standard. Building on the atomic candle concept developed in atomic vapor systems, this method employs phase modulation of MW and resonance with Rabi oscillations to extract the Rabi frequency in the frequency domain. Experiments using NV centers in diamond demonstrated that the MW magnetic field derived from the NV Candle signals exhibited linearity over a 20 dB dynamic range. This work presents a novel approach to realize a solid-state quantum MW standard with enhanced robustness and practical applicability.
Abstract We developed a compact and portable measuring instrument using diamond NV centers that operates on the USB 3.0 power supply of a laptop computer. Its portability is achieved by the low power consumption of the optics, realized by the diamond corner cube that enhanced the current of the photodiode to 2.1 times higher than that of the planar diamond, and that of the microwave source, reduced by 20 dB, which was realized by a microwave resonator using a λ/4 open stub that strongly magnetically drives the NV center. These results contribute to the social implementation of diamond sensors.
One of the promising solid-state quantum sensors is nitrogen-vacancy (NV) centers in diamond which can maintain quantum state at room temperature and under atmospheric pressure condition. Further improvement of sensitivity of the sensor is needed to detect the magnetic field from the brain. Noise reduction and simplified system are key techniques especially for the practical use of highly sensitive DC magnetic sensor. In this study, we devised a digital filtering detection method without synchronization between detector and modulator which is a similar noise reduction effect as a lock-in detection technique. We implemented the detection method for the quantum diamond sensor system with the large sensor volume [1]. The Lock-in detection technique is a typical high sensitivity technique for DC magnetic measurement. There are several different implementations of lock-in detection technique for the quantum diamond sensor including microwave modulation, magnetic field modulation, and laser modulation. However, it is a challenging task to obtain high magnetic sensitivity with a compact sensor module because these lock-in detection techniques require a lock-in amplifier or synchronization system. We devised a digital filtering detection method which is an alternative method to the lock-in detection technique. Fluorescence from the NV center is modulated by frequency modulated microwave during optical detected magnetic resonance (ODMR) measurement. The fluorescence is analyzed by digital signal processing which achieves a similar noise reduction effect as a lock-in detection technique. Our method relies on a fact that ODMR converts frequency modulation to amplitude modulation. Thus, our method is applicable not only to the NV center system but also another color center system. This work was supported by MEXT Q-LEAP, CAO PRISM, Japan. [1] Y. Masuyama et al., Rev. Sci. Instrum. 89, 125007 (2018).
Developing high performance portable sensors is of significant importance for both terrestrial and satellite communications, with quantum sensors offering potential advantages in sensitivity and bandwidth. The nitrogen vacancy center in diamond is a popular quantum sensing platform for its relative simplicity and wide range of acceptable operating conditions, but suffers a limited instantaneous bandwidth due to the narrow linewidth of the spin resonance. In this work, we first present a magnetic quantum sensing scheme utilizing heterodyne mixing with strong optical and microwave driving, achieving MHz-scale instantaneous bandwidth with a sensitivity of 548  pT/Hz548 \; \text{pT/}\sqrt{\text{Hz}}548pT/Hz​ in an active diamond volume of $ 2.5\times 10^{-4} \; \text{mm}^3$ with 2×10112 \times 10^{11}2×1011 NV centers. We then demonstrate expansion of the sensing bandwidth by employing a strong magnetic gradient and many individually modulated microwave control fields, expanding the single resonance bandwidth to 48 MHz with a peak sensitivity of 8.5  nT/Hz8.5 \; \text{nT/}\sqrt{\text{Hz}}8.5nT/Hz​.