Measurement

Magnetic field compensation method of dual-beam SERF atomic magnetometer under probing-axis bias

Xinda Song, Di Wu, Tengyue Long, Zhendong Wu, Le Jia

Published Jun 21, 2025• 7 citations
Publisher
DOI
10.1016/j.measurement.2025.118102

Related papers

Simultaneous in-situ compensation method of residual magnetic fields for the dual-beam SERF atomic magnetometer

Kun Wang, Danyue Ma, Siran Li +2 more

Sensors and Actuators A Physical•Nov 29, 2022•25 citations

Spin-feedback enhancement method for modulated dual-axis SERF atomic magnetometer

Yujian Ma, Ziqi Yuan, Shudong Lin +2 more

Measurement•Aug 18, 2026•0 citations

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•3 citations

Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer

Fei Lu, Shuying Wang, Nuozhou Xu +3 more

Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.

Photonics•Oct 25, 2022•7 citations

Comprehensive analysis of the magnetic field closed-loop control system in SERF atomic magnetometer

Le Jia, Xinda Song, Jianli Li +4 more

Sensors and Actuators A Physical•Jan 21, 2024•16 citations

A Triaxial Dual‐Beam Magnetic Measurement Method Based on Dressed‐Atom Dynamic Evolution Behavior for Miniaturized SERF Atomic Magnetometer

Zhen Li, Xiangyang Zhou, Zihao Lyu +4 more

ABSTRACT Miniaturized spin‐exchange relaxation‐free (SERF) atomic magnetometers have become core sensors for detecting biomagnetic fields, including MEG and MCG, due to their ultra‐high sensitivity and high spatiotemporal resolution. Compared to single‐axis magnetometers, triaxial atomic magnetometers are more attractive which can measure comprehensive three‐dimensional magnetic field information. However, traditional triaxial single‐beam or dual‐beam configurations are constrained by limited longitudinal sensitivity or complex optical architectures unsuitable for miniaturized sensors. In this paper, a triaxial dual‐beam magnetic measurement method based on the dynamic evolution of dressed atoms is proposed. The proposed method employs an overlapping pump–probe configuration to simplify the optical sensing architecture while maintaining high magnetic field sensitivity. By utilizing multi‐frequency signal modulation and parallel demodulation, triaxial magnetic vector components are measured simultaneously. Modulation parameters are experimentally optimized based on a systematic analysis of atomic spin dynamics under dual radio‐frequency (RF) fields. Triaxial couplings under various bias magnetic fields are quantitatively analyzed. Experimental validation using a 4 mm vapor cell demonstrates simultaneous triaxial magnetic field measurements, achieving sensitivities of 84.4, 73.2, and 190.7 fT/Hz 1/2 and corresponding bandwidths of 65, 76, and 78 Hz along the x ‐, y ‐, and z ‐axes, respectively.

Advanced Quantum Technologies•Nov 1, 2026•0 citations
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.
Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.
ABSTRACT Miniaturized spin‐exchange relaxation‐free (SERF) atomic magnetometers have become core sensors for detecting biomagnetic fields, including MEG and MCG, due to their ultra‐high sensitivity and high spatiotemporal resolution. Compared to single‐axis magnetometers, triaxial atomic magnetometers are more attractive which can measure comprehensive three‐dimensional magnetic field information. However, traditional triaxial single‐beam or dual‐beam configurations are constrained by limited longitudinal sensitivity or complex optical architectures unsuitable for miniaturized sensors. In this paper, a triaxial dual‐beam magnetic measurement method based on the dynamic evolution of dressed atoms is proposed. The proposed method employs an overlapping pump–probe configuration to simplify the optical sensing architecture while maintaining high magnetic field sensitivity. By utilizing multi‐frequency signal modulation and parallel demodulation, triaxial magnetic vector components are measured simultaneously. Modulation parameters are experimentally optimized based on a systematic analysis of atomic spin dynamics under dual radio‐frequency (RF) fields. Triaxial couplings under various bias magnetic fields are quantitatively analyzed. Experimental validation using a 4 mm vapor cell demonstrates simultaneous triaxial magnetic field measurements, achieving sensitivities of 84.4, 73.2, and 190.7 fT/Hz 1/2 and corresponding bandwidths of 65, 76, and 78 Hz along the x ‐, y ‐, and z ‐axes, respectively.