Sensors and Actuators A Physical

Simultaneous in-situ compensation method of residual magnetic fields for the dual-beam SERF atomic magnetometer

Kun Wang, Danyue Ma, Siran Li, Yanan Gao, Jinji Sun

Published Nov 29, 2022• 25 citations
Publisher
DOI
10.1016/j.sna.2022.114055

Related papers

Magnetic field compensation method of dual-beam SERF atomic magnetometer under probing-axis bias

Xinda Song, Di Wu, Tengyue Long +2 more

Measurement•Jun 21, 2025•7 citations

In-situ magnetic field compensation for zero-field NMOR atomic magnetometer

Changhao Zhang, Jiali Liu, Xin Hui Zhao +4 more

Sensors and Actuators A Physical•Mar 10, 2025•9 citations

In situ measurement of residual magnetic field in SERF atomic magnetometer based on transient response

Di Zhan, Yaoguo Wang, Jixi Lu

Maintaining a near-zero magnetic field condition is a requisite for atomic magnetometer under the spin-exchange relaxation-free (SERF) regime. Therefore, the precise determination of the residual magnetic fields is of great significance. Herein, we proposed an in-situ measurement method of residual magnetic fields in a dual-beam atomic magnetometer based on a transient response of the transverse polarization along the probe beam direction after switching off the pump beam. Proceeding from the Bloch equation, we established a complete evolution expression of the polarization vector under any static residual magnetic field with the pump beam switched off. On this basis, we analyzed the transient response of the transverse polarization by numerical simulation under different situations of residual magnetic fields. Besides, we also considered two possible conditions when the residual magnetic fields are relatively large or small, respectively. Accordingly, we presented an efficient and convenient estimation method of the residual magnetic fields based on certain time characteristics of the transient response. We verified the feasibility of our method by experiment and achieved a triaxial residual magnetic fields measurement within 0.5 s. This method can realize an in situ and real-time measurement of the residual magnetic fields in a fast and convenient way. Furthermore, this method can evaluate the effectiveness of different magnetic field compensation methods without introducing any modulation or extra devices.

Advanced Sensor Systems and Applications•Nov 20, 2024•0 citations

In situ triaxial magnetic field compensation for the spin-exchange-relaxation-free atomic magnetometer

Jiancheng Fang, Jie Qin

The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.

Review of Scientific Instruments•Oct 1, 2012•69 citations

Spin-feedback enhancement method for modulated dual-axis SERF atomic magnetometer

Yujian Ma, Ziqi Yuan, Shudong Lin +2 more

Measurement•Aug 18, 2026•0 citations

Triaxial Coils In Situ Calibration Method Based on Measuring the Alternating Magnetic Field-Induced Dynamic Response of the SERF Magnetometer

Kun Wang, Danyue Ma, Siran Li +4 more

The calibration results of the triaxial coils affect the atomic magnetometer’s measurement sensitivity. For precise in situ calibration, we first studied the transient atomic dynamics of a dual-beam spin-exchange relaxation free (SERF) atomic magnetometer under alternating magnetic fields. We obtained the corresponding dynamic free-induction-decay (FID) curves by alternately applying square wave signals to the${x}$-,${y}$-, and${z}$-axis coil, and then extracted the precession frequencies by fast Fourier transform (FFT) to achieve a decoupled calibration of the triaxial coil constants. Our calibration results were in better agreement under different experimental conditions than traditional parameter fitting methods with a relative error of less than 1.5% compared to conventional fluxgate calibration methods. Furthermore, we simultaneously measured nonorthogonal angles between each pair of axes: x–y, y–z, and z–x, respectively, which are used to correct the magnetic fields error. This method is suitable for coil calibration and nonorthogonal correction of integrated and miniaturized dual beam magnetometers.

IEEE Sensors Journal•Jul 7, 2023•15 citations
Maintaining a near-zero magnetic field condition is a requisite for atomic magnetometer under the spin-exchange relaxation-free (SERF) regime. Therefore, the precise determination of the residual magnetic fields is of great significance. Herein, we proposed an in-situ measurement method of residual magnetic fields in a dual-beam atomic magnetometer based on a transient response of the transverse polarization along the probe beam direction after switching off the pump beam. Proceeding from the Bloch equation, we established a complete evolution expression of the polarization vector under any static residual magnetic field with the pump beam switched off. On this basis, we analyzed the transient response of the transverse polarization by numerical simulation under different situations of residual magnetic fields. Besides, we also considered two possible conditions when the residual magnetic fields are relatively large or small, respectively. Accordingly, we presented an efficient and convenient estimation method of the residual magnetic fields based on certain time characteristics of the transient response. We verified the feasibility of our method by experiment and achieved a triaxial residual magnetic fields measurement within 0.5 s. This method can realize an in situ and real-time measurement of the residual magnetic fields in a fast and convenient way. Furthermore, this method can evaluate the effectiveness of different magnetic field compensation methods without introducing any modulation or extra devices.
The spin-exchange-relaxation-free (SERF) atomic magnetometer is an ultra-high sensitivity magnetometer, but it must be operated in a magnetic field with strength less than about 10 nT. Magnetic field compensation is an effective way to shield the magnetic field, and this paper demonstrates an in situ triaxial magnetic field compensation system for operating the SERF atomic magnetometer. The proposed hardware is based on optical pumping, which uses some part of the SERF atomic magnetometer itself, and the compensation method is implemented by analyzing the dynamics of the atomic spin. The experimental setup for this compensation system is described, and with this configuration, a residual magnetic field of strength less than 2 nT (±0.38 nT in the x axis, ±0.43 nT in the y axis, and ±1.62 nT in the z axis) has been achieved after compensation. The SERF atomic magnetometer was then used to verify that the residual triaxial magnetic fields were coincident with what were achieved by the compensation system.
The calibration results of the triaxial coils affect the atomic magnetometer’s measurement sensitivity. For precise in situ calibration, we first studied the transient atomic dynamics of a dual-beam spin-exchange relaxation free (SERF) atomic magnetometer under alternating magnetic fields. We obtained the corresponding dynamic free-induction-decay (FID) curves by alternately applying square wave signals to thex{x}x-,y{y}y-, andz{z}z-axis coil, and then extracted the precession frequencies by fast Fourier transform (FFT) to achieve a decoupled calibration of the triaxial coil constants. Our calibration results were in better agreement under different experimental conditions than traditional parameter fitting methods with a relative error of less than 1.5% compared to conventional fluxgate calibration methods. Furthermore, we simultaneously measured nonorthogonal angles between each pair of axes: x–y, y–z, and z–x, respectively, which are used to correct the magnetic fields error. This method is suitable for coil calibration and nonorthogonal correction of integrated and miniaturized dual beam magnetometers.