Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Sensors Journal

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang, Ke‐Qin Zhang, Xiaodong Yang

Published Jan 7, 2025• 3 citations
Publisher

Abstract

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

DOI
10.1109/jsen.2024.3521412

Related papers

Suppression Method of AC-Stark Shift in SERF Atomic Magnetometer

Yang Li, Ming Ding, Xuejing Liu +3 more

In a spin-exchange-relaxation-free (SERF) atomic magnetometer with ultrahigh sensitivity, the ac-Stark shift generated by circularly polarized light results in the attenuation of the SERF atomic magnetometer response, and the virtual magnetic field gradient induced by the ac-Stark shift can reduce the sensitivity of the SERF atomic magnetometer. In this paper, we use a hybrid optical pumping method to address the ac-Stark shift problem. By switching between left-hand and right-hand circularly polarized lights and compensating the residual magnetic field of the magnetometer, the ac-Stark shift could be reduced and then suppressed effectively.

IEEE photonics journal•Sep 27, 2018•22 citations

Pulsed-Modulation Single-Beam Three-Axis Atomic Magnetometer

Shushan Gao, Xiaoyu Li, Jianwei Sheng +5 more

The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz${}^{\text {1/2}}$for the$x$- and$y$-axes, and a longitudinal sensitivity of 70 fT/Hz${}^{\text {1/2}}$for the$z$-axis in a$4\times 4\times 4$mm${}^{\text {3 87}}$Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2026•0 citations

Dual-Axis Closed Loop of a Single-Beam Atomic Magnetometer: Toward High Bandwidth and High Sensitivity

Junjian Tang, Yueyang Zhai, Binquan Zhou +2 more

Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2021•95 citations

Single-light-source three-axis atomic magnetometer based on orthogonal and non-overlapping dual-pump beams

Lin Li, Junjian Tang, Binbin Zhao +1 more

In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.

Results in Physics•Jul 13, 2023•7 citations

Single-beam triaxial spin-exchange relaxation-free atomic magnetometer utilizing transverse modulation fields

Lin Li, Junjian Tang, Binbin Zhao +3 more

Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.

Journal of Physics D Applied Physics•Oct 24, 2022•23 citations

Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer

Fei Lu, Shuying Wang, Nuozhou Xu +3 more

Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.

Photonics•Oct 25, 2022•7 citations
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.
In a spin-exchange-relaxation-free (SERF) atomic magnetometer with ultrahigh sensitivity, the ac-Stark shift generated by circularly polarized light results in the attenuation of the SERF atomic magnetometer response, and the virtual magnetic field gradient induced by the ac-Stark shift can reduce the sensitivity of the SERF atomic magnetometer. In this paper, we use a hybrid optical pumping method to address the ac-Stark shift problem. By switching between left-hand and right-hand circularly polarized lights and compensating the residual magnetic field of the magnetometer, the ac-Stark shift could be reduced and then suppressed effectively.
The three-axis spin-exchange relaxation-free (SERF) atomic magnetometer (AM) enables full-vector magnetic field measurements with high sensitivity, offering significant potential for improving the accuracy of magnetic source reconstruction. However, most existing three-axis schemes rely on multiple continuous high-frequency modulation fields, which reintroduce spin-exchange relaxation and induce interaxis crosstalk. Here, we propose a three-axis magnetic field measurement method based on pulsed magnetic field modulation. By applying a transverse rotating pulsed field and a longitudinal pulsed field, the three-axis components of the vector magnetic field can be extracted from the longitudinal transmitted optical signal. The pulsed magnetic field reduces the continuous interaction time of the modulation field via its duty cycle, thereby suppressing spin-exchange relaxation. The designed synchronized time-division three-axis pulsed fields avoid the coupling effect of multiaxis modulation on spin polarization in the overlap region, thus effectively minimizing interaxis crosstalk while enabling real-time three-axis measurement. Experimental results demonstrate that the proposed method reduces the modulation-induced spin-exchange relaxation rate by approximately 40 %, achieving transverse dual-axis sensitivity of 13 fT/Hz1/2{}^{\text {1/2}}1/2for thexxx- andyyy-axes, and a longitudinal sensitivity of 70 fT/Hz1/2{}^{\text {1/2}}1/2for thezzz-axis in a4×4×44\times 4\times 44×4×4mm3 87{}^{\text {3 87}}3 87Rb vapor cell. The interaxis crosstalk is suppressed to less than 1 % over the 1–100-Hz bandwidth. The proposed scheme provides new insights for constructing compact and low-cost single-beam three-axis SERF AMs.
Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.
In this paper, we propose a three-axis atomic magnetometer (AM), in which one light beam is divided into two orthogonal spatially separated pump beams by a lateral displacement polarized beam splitter and reflector mirrors; this scheme suppresses the three-axis crosstalk caused by the interaction between the two beams and atoms in the cell. When the AM operates in the direct-current (DC) mode, the three-axis crosstalk is significant. To solve this problem, three modulation fields with the same amplitudes, frequencies, and different phases are applied, which allow the AM operated in modulation mode to perform a highly sensitive synchronous and independent measurement of the three-axis magnetic field with low crosstalk. The experimental results showed that the three-axis crosstalk was less than 2%. In the modulation mode, the sensitivities were 22, 23, and 26 fT/Hz1/2 on the x-, y-, and z-axes, respectively. The 3-dB bandwidths of the three axes were 126, 124, and 112 Hz. In addition, we demonstrated a three-axis in-situ magnetic compensation method with a magnetic compensation accuracy of the pT level in the DC mode. The proposed triaxial AM can be easily miniaturised and used in biomedical applications, such as in magnetocardiography and magnetoencephalography.
Abstract We display a single-beam triaxial spin-exchange relaxation-free (SERF) atomic magnetometer by utilizing two orthogonal transverse modulation fields perpendicular to the light. The magnetic field’s three-axis vector components can be extracted simultaneously and independently from the transmitted light by lock-in amplifiers with reference to the different demodulated frequencies. We find that the residual magnetic field is a significant factor that could affect triaxial coupling, and specially the influence of the z -axis remanence on xy -axis coupling is studied in detail. Under the optimal parameters, the three-axis sensitivities are 20 fT Hz − 1 / 2 in the x - and y - axis, and 230 fT Hz − 1 / 2 in the z -axis. Meanwhile, the three-axis bandwidths are 110 Hz, 138 Hz and 211 Hz in the x -, y - and z -axis, respectively. The proposed single-beam triaxial SERF atomic magnetometer could be used to construct a compact and low-cost atomic sensor that is particularly suitable for the vector measurement of the biomagnetic such as magnetoencephalography and magnetocardiography.
Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.