Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics B

Resolving gravitational redshift with sub-millimeter height differences using spin-squeezed optical clocks

Deshui Yu, Jia Zhang, Shougang Zhang, Tiantian Shi, Jingbiao Chen

Published Apr 8, 2025• 1 citation
Publisher

Abstract

Abstract The phenomenon that a clock at a higher gravitational potential ticks faster than one at a lower potential, also known as gravitational redshift, is one of the classical tests of Einstein’s theory of general relativity. Owing to their ultra-high accuracy and stability, state-of-the-art optical lattice clocks have enabled resolving the gravitational redshift with a millimeter-scale height difference. Further reducing the vertical inter-clock separation down to the sub-millimeter level and especially shortening the required measurement time may be achieved by employing spin squeezing. Here, we theoretically investigate the spin-squeezing-enhanced differential frequency comparison between two optical clocks within a lattice-trapped cloud of 171Yb atoms. The numerical results illustrate that for a sample of 104 atoms, the atomic-collision-limited resolution of the vertical separation between two clocks can reach 0.48 mm, corresponding to a fractional gravitational redshift at the 10−20 level. In addition, the required averaging time may be reduced to less than one hundredth of that of conventional clocks with independent atoms. Our work opens a door to the future spin-squeezing-enhanced test of general relativity.

DOI
10.1088/1674-1056/adca1d

Related papers

Decoherence of Atomic Ensembles in Optical Lattice Clocks by Gravity

Akio Kawasaki

Optical lattice clocks can now resolve the height difference below 1 mm within an atomic ensemble by means of gravitational redshift with integration over sufficient amount of time. Further improvement in the stability enables the clocks to resolve the height difference of subsystems within an atomic ensemble that is conventionally interrogated as a single coherent spin state in a single Ramsey sequence, resulting in the dephasing of the coherent spin state. This effect is observable with a clock of a stability of $\lesssim 10^{-21}$ by introducing a single-layer-resolved imaging system for a three-dimensional optical lattice, and limits the 1 s stability of the clock around $10^{-19}$ for an atomic ensemble distributing symmetrically for the three axes, which is also a signal of the decoherence. With atoms in an entangled state, this can be the first observation of the decoherence of a quantum state by a gravitational effect, and the suppression of other systematic shifts to observe this decoherence seems feasible.

arXiv:2107.02405•Journal of the Physical Society of Japan•Feb 2, 2022•2 citations

Test of the gravitational redshift with single-photon-based atomic clock interferometers

Ju Liu, Yaoyao Xu, Hua-Qing Luo +4 more

Abstract The gravitational redshift (GR), as predicted by Einstein’s general theory of relativity, posits that two identical clocks situated at different gravitational potentials will tick at different rates. In this study, we explore the impact of the GR on a single-photon-based atom interferometer and propose a corresponding testing scheme. Our approach conceptualizes the atom interferometer as two coherent atomic clocks positioned at distinct elevations, which is referred to as an atomic clock interferometer, allowing us to derive the GR-induced phase shift. This effect becomes significant due to the notable energy difference between the two atomic internal states, comparable to other relativistic effects in single-photon-based atomic clock interferometers. Furthermore, our proposed scheme incorporates the velocity of the laser device to effectively mitigate other relativistic effects. The ensuing analysis indicates an anticipated GR test precision at the 10−5 level for our proposed approach.

Quantum Frontiers•Feb 8, 2024•4 citations

A Multiplexed Strontium Optical Lattice Clock

Jonathan Dolde

Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.

•May 1, 2026•0 citations

Spin-squeezing-enhanced optical lattice clocks with 10 − 19 -level differential frequency stability at the averaging time of 1 s

Deshui Yu, Jia Zhang, Tongyan Xia +3 more

Many-body entangled states allow precision measurement beyond the standard quantum limit. Yet they have not been effectively exploited in optical lattice clocks except for proof-of-principle demonstrations. Under the current experimental conditions, taking into account the lattice perturbation, atom-atom interactions, and local oscillator noise, we theoretically evaluate the performance of spin-squeezing-based shallow-lattice Yb optical clocks. The numerical simulation shows that the stability of differential frequency comparison between two Yb ensembles in squeezed spin states potentially accesses the ${10}^{\ensuremath{-}19}$ level at the averaging time of 1 s. The resultant Wineland parameter may be as low as ${\ensuremath{\xi}}_{\text{W}}^{2}=0.027$, corresponding to a reduction of averaging time by a factor of 37, and is limited by the collision-induced degradation of spin squeezing. The metrological gain provided by spin squeezing opens up new opportunities for precision measurement and fundamental physics.

Physical Review A•Jul 1, 2024•4 citations

Measuring gravitational time dilation with delocalized quantum superpositions

Albert Roura, Christian Schubert, Dennis Schlippert +1 more

Atomic clocks can measure the gravitational redshift predicted by general relativity with great accuracy and for height differences as little as 1 cm. All existing experiments, however, involve the comparison of two independent clocks at different locations rather than a single clock in a delocalized quantum superposition. Here we present an interferometry scheme employing group-II-type atoms, such as Sr or Yb, capable of measuring the gravitational time dilation in a coherent superposition of atomic wave packets at two different heights. In contrast to other recent proposals, there is no need for pulses that can efficiently diffract both internal states. Instead, the scheme relies on very simple atom optics for which high diffraction efficiencies can be achieved with rather mild requirements on laser power. Furthermore, the effects of vibration noise are subtracted by employing a simultaneous Rb interferometer that acts as an inertial reference. Remarkably, the recently commissioned VLBAI facility in Hannover, a 10-m atomic fountain that can simultaneously operate Yb and Rb atoms and enables up to 2.8 s of free evolution time, meets all the requirements for a successful experimental implementation.

arXiv:2010.11156•Physical review. D/Physical review. D.•Oct 1, 2021•40 citations

Quantum enhanced metrology in the optical lattice clock

Chi Shu

High-bandwidth, high-stability clocks offer unique chances to study fundamental physics beyond simple metrology. Today, the most stable clocks are optical lattice clocks and they can reach a fractional stability of 3.1 × 10^−18 at 1 s averaging time. Their applications are ranging from the redefinition of the SI time unit, the Second, to the possible detection of gravitational waves in space. The stability of optical lattice clocks is primarily limited by quantum projection noise and Dick noise. In this thesis, I present our effort in creating a platform for studying quantum enhanced metrology and its application towards optical lattice clocks. We demonstrated the laser cooling in an optical cavity with Raman-sideband cooling and achieved average vibration number of n = 0.2. We utilized cavity feedback squeezing to demonstrate unitary spin squeezing on magnetic sub-levels of 171Yb, achieving 6.5 dB quantum projection noise reduction over the standard quantum limit (SQL). With coherent optical state transfer by ultra stable laser pulses, we successfully transferred the spin squeezed state from magnetic sub-levels to the optical transition, and demonstrated quantum enhanced metrology in the optical lattice clock for the first time. We achieved 4.4 dB of metrological gain over the SQL, which corresponds to a reduction of the averaging time by a factor of 2.8 in clock operation. Furthermore, we studied quantum enhanced metrology with time-reversal-based protocols. We performed a signal amplification through time-reversed interaction protocol between the ground state magnetic sublevels of 171Yb, achieving the largest sensitivity improvement beyond SQL in any interferometers to date at 11.8dB. Besides that, we experimentally studied the connection between quantum information scrambling, by measuring out-of-time-order correlators (OTOCs), and quantum metrology, by measuring metrological gain. We found these values to agree with each other, and concluded that the time-reversal quantum metrology can saturate the attainable gain from the quantum information scrambling.

•Jan 1, 2023•0 citations
Abstract The phenomenon that a clock at a higher gravitational potential ticks faster than one at a lower potential, also known as gravitational redshift, is one of the classical tests of Einstein’s theory of general relativity. Owing to their ultra-high accuracy and stability, state-of-the-art optical lattice clocks have enabled resolving the gravitational redshift with a millimeter-scale height difference. Further reducing the vertical inter-clock separation down to the sub-millimeter level and especially shortening the required measurement time may be achieved by employing spin squeezing. Here, we theoretically investigate the spin-squeezing-enhanced differential frequency comparison between two optical clocks within a lattice-trapped cloud of 171Yb atoms. The numerical results illustrate that for a sample of 104 atoms, the atomic-collision-limited resolution of the vertical separation between two clocks can reach 0.48 mm, corresponding to a fractional gravitational redshift at the 10−20 level. In addition, the required averaging time may be reduced to less than one hundredth of that of conventional clocks with independent atoms. Our work opens a door to the future spin-squeezing-enhanced test of general relativity.
Optical lattice clocks can now resolve the height difference below 1 mm within an atomic ensemble by means of gravitational redshift with integration over sufficient amount of time. Further improvement in the stability enables the clocks to resolve the height difference of subsystems within an atomic ensemble that is conventionally interrogated as a single coherent spin state in a single Ramsey sequence, resulting in the dephasing of the coherent spin state. This effect is observable with a clock of a stability of ≲10−21\lesssim 10^{-21}≲10−21 by introducing a single-layer-resolved imaging system for a three-dimensional optical lattice, and limits the 1 s stability of the clock around 10−1910^{-19}10−19 for an atomic ensemble distributing symmetrically for the three axes, which is also a signal of the decoherence. With atoms in an entangled state, this can be the first observation of the decoherence of a quantum state by a gravitational effect, and the suppression of other systematic shifts to observe this decoherence seems feasible.
Abstract The gravitational redshift (GR), as predicted by Einstein’s general theory of relativity, posits that two identical clocks situated at different gravitational potentials will tick at different rates. In this study, we explore the impact of the GR on a single-photon-based atom interferometer and propose a corresponding testing scheme. Our approach conceptualizes the atom interferometer as two coherent atomic clocks positioned at distinct elevations, which is referred to as an atomic clock interferometer, allowing us to derive the GR-induced phase shift. This effect becomes significant due to the notable energy difference between the two atomic internal states, comparable to other relativistic effects in single-photon-based atomic clock interferometers. Furthermore, our proposed scheme incorporates the velocity of the laser device to effectively mitigate other relativistic effects. The ensuing analysis indicates an anticipated GR test precision at the 10−5 level for our proposed approach.
Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.
Many-body entangled states allow precision measurement beyond the standard quantum limit. Yet they have not been effectively exploited in optical lattice clocks except for proof-of-principle demonstrations. Under the current experimental conditions, taking into account the lattice perturbation, atom-atom interactions, and local oscillator noise, we theoretically evaluate the performance of spin-squeezing-based shallow-lattice Yb optical clocks. The numerical simulation shows that the stability of differential frequency comparison between two Yb ensembles in squeezed spin states potentially accesses the ${10}^{\ensuremath{-}19}$ level at the averaging time of 1 s. The resultant Wineland parameter may be as low as ${\ensuremath{\xi}}_{\text{W}}^{2}=0.027$, corresponding to a reduction of averaging time by a factor of 37, and is limited by the collision-induced degradation of spin squeezing. The metrological gain provided by spin squeezing opens up new opportunities for precision measurement and fundamental physics.
Atomic clocks can measure the gravitational redshift predicted by general relativity with great accuracy and for height differences as little as 1 cm. All existing experiments, however, involve the comparison of two independent clocks at different locations rather than a single clock in a delocalized quantum superposition. Here we present an interferometry scheme employing group-II-type atoms, such as Sr or Yb, capable of measuring the gravitational time dilation in a coherent superposition of atomic wave packets at two different heights. In contrast to other recent proposals, there is no need for pulses that can efficiently diffract both internal states. Instead, the scheme relies on very simple atom optics for which high diffraction efficiencies can be achieved with rather mild requirements on laser power. Furthermore, the effects of vibration noise are subtracted by employing a simultaneous Rb interferometer that acts as an inertial reference. Remarkably, the recently commissioned VLBAI facility in Hannover, a 10-m atomic fountain that can simultaneously operate Yb and Rb atoms and enables up to 2.8 s of free evolution time, meets all the requirements for a successful experimental implementation.
High-bandwidth, high-stability clocks offer unique chances to study fundamental physics beyond simple metrology. Today, the most stable clocks are optical lattice clocks and they can reach a fractional stability of 3.1 × 10^−18 at 1 s averaging time. Their applications are ranging from the redefinition of the SI time unit, the Second, to the possible detection of gravitational waves in space. The stability of optical lattice clocks is primarily limited by quantum projection noise and Dick noise. In this thesis, I present our effort in creating a platform for studying quantum enhanced metrology and its application towards optical lattice clocks. We demonstrated the laser cooling in an optical cavity with Raman-sideband cooling and achieved average vibration number of n = 0.2. We utilized cavity feedback squeezing to demonstrate unitary spin squeezing on magnetic sub-levels of 171Yb, achieving 6.5 dB quantum projection noise reduction over the standard quantum limit (SQL). With coherent optical state transfer by ultra stable laser pulses, we successfully transferred the spin squeezed state from magnetic sub-levels to the optical transition, and demonstrated quantum enhanced metrology in the optical lattice clock for the first time. We achieved 4.4 dB of metrological gain over the SQL, which corresponds to a reduction of the averaging time by a factor of 2.8 in clock operation. Furthermore, we studied quantum enhanced metrology with time-reversal-based protocols. We performed a signal amplification through time-reversed interaction protocol between the ground state magnetic sublevels of 171Yb, achieving the largest sensitivity improvement beyond SQL in any interferometers to date at 11.8dB. Besides that, we experimentally studied the connection between quantum information scrambling, by measuring out-of-time-order correlators (OTOCs), and quantum metrology, by measuring metrological gain. We found these values to agree with each other, and concluded that the time-reversal quantum metrology can saturate the attainable gain from the quantum information scrambling.