Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:2107.02405 · Journal of the Physical Society of Japan

Decoherence of Atomic Ensembles in Optical Lattice Clocks by Gravity

Akio Kawasaki

Published Feb 2, 2022• 2 citations
arXivHTMLPDF

Abstract

Optical lattice clocks can now resolve the height difference below 1 mm within an atomic ensemble by means of gravitational redshift with integration over sufficient amount of time. Further improvement in the stability enables the clocks to resolve the height difference of subsystems within an atomic ensemble that is conventionally interrogated as a single coherent spin state in a single Ramsey sequence, resulting in the dephasing of the coherent spin state. This effect is observable with a clock of a stability of $\lesssim 10^{-21}$ by introducing a single-layer-resolved imaging system for a three-dimensional optical lattice, and limits the 1 s stability of the clock around $10^{-19}$ for an atomic ensemble distributing symmetrically for the three axes, which is also a signal of the decoherence. With atoms in an entangled state, this can be the first observation of the decoherence of a quantum state by a gravitational effect, and the suppression of other systematic shifts to observe this decoherence seems feasible.

DOI
10.7566/jpsj.91.034301

Related papers

Resolving gravitational redshift with sub-millimeter height differences using spin-squeezed optical clocks

Deshui Yu, Jia Zhang, Shougang Zhang +2 more

Abstract The phenomenon that a clock at a higher gravitational potential ticks faster than one at a lower potential, also known as gravitational redshift, is one of the classical tests of Einstein’s theory of general relativity. Owing to their ultra-high accuracy and stability, state-of-the-art optical lattice clocks have enabled resolving the gravitational redshift with a millimeter-scale height difference. Further reducing the vertical inter-clock separation down to the sub-millimeter level and especially shortening the required measurement time may be achieved by employing spin squeezing. Here, we theoretically investigate the spin-squeezing-enhanced differential frequency comparison between two optical clocks within a lattice-trapped cloud of 171Yb atoms. The numerical results illustrate that for a sample of 104 atoms, the atomic-collision-limited resolution of the vertical separation between two clocks can reach 0.48 mm, corresponding to a fractional gravitational redshift at the 10−20 level. In addition, the required averaging time may be reduced to less than one hundredth of that of conventional clocks with independent atoms. Our work opens a door to the future spin-squeezing-enhanced test of general relativity.

Chinese Physics B•Apr 8, 2025•1 citation

Reducing the Instability of an Optical Lattice Clock Using Multiple Atomic Ensembles

Xin Zheng, Jonathan Dolde, Shimon Kolkowitz

The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening the coherent interrogation times, and introducing entanglement to push beyond the standard quantum limit. In this work, we experimentally demonstrate an alternative approach to reducing clock instability using a phase estimation approach based on individually controlled atomic ensembles in a strontium (Sr) optical lattice clock. We first demonstrate joint Ramsey interrogation of two spatially resolved atom ensembles that are out of phase with respect to each other, which we call “quadrature Ramsey spectroscopy,” resulting in a factor of 1.36(5) reduction in absolute clock instability as measured with interleaved self-comparisons. We then leverage the rich hyperfine structure of Sr87 to realize independent coherent control over multiple ensembles with only global laser addressing. Finally, we utilize this independent control over four atom ensembles to implement a form of phase estimation, achieving a factor of greater than 3 enhancement in coherent interrogation time and a factor of 2.08(6) reduction in instability over an otherwise identical single-ensemble clock with the same local oscillator and the same number of atoms. We expect that multiensemble protocols similar to those demonstrated here will result in reduction in the instability of any optical lattice clock with an interrogation time limited by the local oscillator. Published by the American Physical Society 2024

arXiv:2305.12315•Physical Review X•Jan 23, 2024•19 citations

Gravitational Interactions in Nuclear Clocks

Konstantin Beyer, Niklas E. Önne, Shimon Kolkowitz +4 more

Atomic clocks achieve extraordinary precision through quantum control over large ensembles of atoms, with precision increasing and atom number advancing steadily. Emerging nuclear clock technology encodes clock states in nuclear rather than electronic transitions, offering a new frontier for precision measurement. Here we study whether a large ensemble of such clock nuclei could be used to observe their mutual gravitational interaction. We investigate the gravitational redshift induced by neighboring atoms, including nuclear energy superpositions as sources of gravity, giving rise to a genuinely quantum gravitational interaction between pairs of nuclei. We find that the resulting clock frequency shift due to mutual gravity may become non-negligible for a macroscopic number of nuclei, for instance in a solid-state thorium clock, and we propose approaches to mitigate electromagnetic field effects by exploiting spatial symmetry and high-precision spectroscopy. We further discuss how energy-induced mass superpositions could be directly probed using external gravitational field sensors. By contrast, observing gravity-induced entanglement involving clocks would require substantially greater experimental advances due to decoherence from spontaneous emission. Taken together, our results suggest that nuclear clocks, either alone or in combination with complementary sensors such as optomechanical systems, may offer a future route toward probing gravity at short distances and testing gravitating quantum source masses beyond the Newtonian limit.

quant-pharXiv:2610.38832•Oct 30, 2026

A Multiplexed Strontium Optical Lattice Clock

Jonathan Dolde

Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.

•May 1, 2026•0 citations

Enhancing Optical Lattice Clock Coherence Times with Erasure Conversion

Shuo Ma, Jonathan Dolde, Xin Zheng +6 more

Increasing coherent interrogation times is central to advancing the precision of optical clocks. Synchronous differential optical clock comparisons have now demonstrated atomic coherence times that far exceed the coherence time of the clock laser. While atom coherence times are then primarily limited by errors induced by lattice Raman scattering, excited clock state radiative decay, and broadening from two-body collisions, many of these errors take the atoms out of the clock transition subspace, and can therefore be converted into “erasure” errors if the appropriate readout scheme is employed. Here we experimentally demonstrate a hyperfine-resolved readout technique for 87 Sr optical lattice clocks that mitigates decoherence from Raman scattering induced by the lattice as well as radiative decay. By employing hyperfine-resolved readout in synchronous differential comparisons between 87 Sr ensembles with both Ramsey and spin-echo spectroscopy sequences, we achieve enhanced atomic coherence times exceeding 100 and 150 s, respectively, enabling longer coherent measurements without a reduction in performance. We anticipate that this hyperfine-resolved readout technique will benefit applications of state-of-the-art optical lattice clock comparisons in which the coherence times are constrained by Raman scattering or radiative decay.

arXiv:2505.06437•PRX Quantum•Nov 19, 2025•4 citations

Classical gravitational effect on the standard quantum limit of finite-size optical lattice clocks in estimating gravitational potential

Fumiya Nishimura, Yui Kuramochi, Kazuhiro Yamamoto

We evaluated the accuracy limit for estimating gravitational potential using optical lattice clocks by utilizing the quantum Cram\'er-Rao bound. We then compared the results for single-layer and multilayer optical lattice clocks. The results indicate that the lower bound of variance of the estimator of gravitational potential using finite-size optical lattice clocks diverges and recovers repeatedly as a function of time. Namely, the accuracy of the gravitational potential estimation is not a monotonic function of time owing to the effect of gravitational dephasing in finite-size optical lattice clocks. Further, this effect creates an estimation accuracy limit when attempting to avoid the divergence of the lower bound. When the number of layers in the optical lattice clock is sufficiently large, the limit is independent of the optical lattice clock details. The time required to reach this limit is calculated to be approximately 33 h for a three-dimensional optical lattice clock consisting of one million cadmium atoms due to Earth's gravity, and approximately the same for other atoms. This time is much longer than the current coherence time of $26\phantom{\rule{0.16em}{0ex}}\mathrm{s}$.

arXiv:2308.03335•Physical Review A•Dec 28, 2023•0 citations
Optical lattice clocks can now resolve the height difference below 1 mm within an atomic ensemble by means of gravitational redshift with integration over sufficient amount of time. Further improvement in the stability enables the clocks to resolve the height difference of subsystems within an atomic ensemble that is conventionally interrogated as a single coherent spin state in a single Ramsey sequence, resulting in the dephasing of the coherent spin state. This effect is observable with a clock of a stability of ≲10−21\lesssim 10^{-21}≲10−21 by introducing a single-layer-resolved imaging system for a three-dimensional optical lattice, and limits the 1 s stability of the clock around 10−1910^{-19}10−19 for an atomic ensemble distributing symmetrically for the three axes, which is also a signal of the decoherence. With atoms in an entangled state, this can be the first observation of the decoherence of a quantum state by a gravitational effect, and the suppression of other systematic shifts to observe this decoherence seems feasible.
Abstract The phenomenon that a clock at a higher gravitational potential ticks faster than one at a lower potential, also known as gravitational redshift, is one of the classical tests of Einstein’s theory of general relativity. Owing to their ultra-high accuracy and stability, state-of-the-art optical lattice clocks have enabled resolving the gravitational redshift with a millimeter-scale height difference. Further reducing the vertical inter-clock separation down to the sub-millimeter level and especially shortening the required measurement time may be achieved by employing spin squeezing. Here, we theoretically investigate the spin-squeezing-enhanced differential frequency comparison between two optical clocks within a lattice-trapped cloud of 171Yb atoms. The numerical results illustrate that for a sample of 104 atoms, the atomic-collision-limited resolution of the vertical separation between two clocks can reach 0.48 mm, corresponding to a fractional gravitational redshift at the 10−20 level. In addition, the required averaging time may be reduced to less than one hundredth of that of conventional clocks with independent atoms. Our work opens a door to the future spin-squeezing-enhanced test of general relativity.
The stability of an optical atomic clock is a critical figure of merit for almost all clock applications. To this end, much optical atomic clock research has focused on reducing clock instability by increasing the atom number, lengthening the coherent interrogation times, and introducing entanglement to push beyond the standard quantum limit. In this work, we experimentally demonstrate an alternative approach to reducing clock instability using a phase estimation approach based on individually controlled atomic ensembles in a strontium (Sr) optical lattice clock. We first demonstrate joint Ramsey interrogation of two spatially resolved atom ensembles that are out of phase with respect to each other, which we call “quadrature Ramsey spectroscopy,” resulting in a factor of 1.36(5) reduction in absolute clock instability as measured with interleaved self-comparisons. We then leverage the rich hyperfine structure of Sr87 to realize independent coherent control over multiple ensembles with only global laser addressing. Finally, we utilize this independent control over four atom ensembles to implement a form of phase estimation, achieving a factor of greater than 3 enhancement in coherent interrogation time and a factor of 2.08(6) reduction in instability over an otherwise identical single-ensemble clock with the same local oscillator and the same number of atoms. We expect that multiensemble protocols similar to those demonstrated here will result in reduction in the instability of any optical lattice clock with an interrogation time limited by the local oscillator. Published by the American Physical Society 2024
Atomic clocks achieve extraordinary precision through quantum control over large ensembles of atoms, with precision increasing and atom number advancing steadily. Emerging nuclear clock technology encodes clock states in nuclear rather than electronic transitions, offering a new frontier for precision measurement. Here we study whether a large ensemble of such clock nuclei could be used to observe their mutual gravitational interaction. We investigate the gravitational redshift induced by neighboring atoms, including nuclear energy superpositions as sources of gravity, giving rise to a genuinely quantum gravitational interaction between pairs of nuclei. We find that the resulting clock frequency shift due to mutual gravity may become non-negligible for a macroscopic number of nuclei, for instance in a solid-state thorium clock, and we propose approaches to mitigate electromagnetic field effects by exploiting spatial symmetry and high-precision spectroscopy. We further discuss how energy-induced mass superpositions could be directly probed using external gravitational field sensors. By contrast, observing gravity-induced entanglement involving clocks would require substantially greater experimental advances due to decoherence from spontaneous emission. Taken together, our results suggest that nuclear clocks, either alone or in combination with complementary sensors such as optomechanical systems, may offer a future route toward probing gravity at short distances and testing gravitating quantum source masses beyond the Newtonian limit.
Optical atomic clocks have spurred a range of precision frequency comparison experiments and proposals including tests of general relativity, gravitational wave detection, and relativistic geodesy. Current measurements using optical atomic clocks are often limited by the coherence of the clock laser rather than the atomic samples used as a frequency reference. In order to overcome the performance limits imposed by clock laser coherence, we realize a multiplexed optical clock system where multiple spatially resolved ensembles each consisting of thousands of strontium atoms trapped in a 1D optical lattice function as separate atomic frequency references that can be simultaneously interrogated with a shared clock laser. This scheme allows us to make differential frequency comparisons with a quantum projection noise limited fractional instability of 9.7(4)×10−18/ √τ and a differential fractional uncertainty of 8.9×10−20 after 3.3 hours of averaging. We then use this system to perform a lab-based test of the gravitational redshift at the centimeter scale, where we measure a fractional frequency gradient of [−12.4±0.7stat ±2.5sys]×10−19/cm, consistent with the predicted value of 10.9×10−19/cm. Having demonstrated that our differential comparisons are no longer limited by the local oscillator, we turn to fundamental limits on atom–atom coherence. We perform a direct decay measurement of the natural lifetime of the excited clock state 3P0 in 87Sr, in which we use measurements of simultaneously loaded high and low density atomic ensembles and compare decay rates of 87Sr and 88Sr to help isolate natural lifetime decay from other population dynamics. We measure a lifetime of 167+79 −40, which is consistent with previously reported experimental and theoretical values. Lastly, we demonstrate a hyperfine-resolved readout scheme in 87Sr that converts depolarization errors during interrogation into erasure errors, extending coherence times between ensembles in our optical lattice clock up to 150s using spin-echo measurements. These results taken together demonstrate the advantages of differential clock measurements that aren’t limited by clock laser coherence and how to characterize and improve on the performance limits that arise in that regime.
Increasing coherent interrogation times is central to advancing the precision of optical clocks. Synchronous differential optical clock comparisons have now demonstrated atomic coherence times that far exceed the coherence time of the clock laser. While atom coherence times are then primarily limited by errors induced by lattice Raman scattering, excited clock state radiative decay, and broadening from two-body collisions, many of these errors take the atoms out of the clock transition subspace, and can therefore be converted into “erasure” errors if the appropriate readout scheme is employed. Here we experimentally demonstrate a hyperfine-resolved readout technique for 87 Sr optical lattice clocks that mitigates decoherence from Raman scattering induced by the lattice as well as radiative decay. By employing hyperfine-resolved readout in synchronous differential comparisons between 87 Sr ensembles with both Ramsey and spin-echo spectroscopy sequences, we achieve enhanced atomic coherence times exceeding 100 and 150 s, respectively, enabling longer coherent measurements without a reduction in performance. We anticipate that this hyperfine-resolved readout technique will benefit applications of state-of-the-art optical lattice clock comparisons in which the coherence times are constrained by Raman scattering or radiative decay.
We evaluated the accuracy limit for estimating gravitational potential using optical lattice clocks by utilizing the quantum Cram\'er-Rao bound. We then compared the results for single-layer and multilayer optical lattice clocks. The results indicate that the lower bound of variance of the estimator of gravitational potential using finite-size optical lattice clocks diverges and recovers repeatedly as a function of time. Namely, the accuracy of the gravitational potential estimation is not a monotonic function of time owing to the effect of gravitational dephasing in finite-size optical lattice clocks. Further, this effect creates an estimation accuracy limit when attempting to avoid the divergence of the lower bound. When the number of layers in the optical lattice clock is sufficiently large, the limit is independent of the optical lattice clock details. The time required to reach this limit is calculated to be approximately 33 h for a three-dimensional optical lattice clock consisting of one million cadmium atoms due to Earth's gravity, and approximately the same for other atoms. This time is much longer than the current coherence time of 26s26\phantom{\rule{0.16em}{0ex}}\mathrm{s}26s.