Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Miniaturized Rb two-photon clock

Martin Callejo, Andrei Mursa, Rémy Vicarini, Jacques Millo, Nicolas Passilly, Rodolphe Boudot

Published Jun 28, 2024• 0 citations
OpenAlex

Abstract

In this work, we present the in-progress development at FEMTO-ST of a Rb microcell two-photon absorption optical reference. The latter uses an external-cavity diode laser (ECDL) at 778 nm and an AOM for controlling the laser power. The laser beam is sent to a Rb MEMS cell1 and reflected back using a dichroic mirror. TPA fluorescence photons at 420 nm are detected with a photomultiplier. The laser is stabilized onto the Rb87 Fg=2, Fe=4 transition.

Related papers

Microfabricated vapor cell atomic clocks at FEMTO-ST

Clément Carlé, Martin Callejo, Andrei Mursa +8 more

The convergence of atomic spectroscopy, MEMS cell technologies and integrated photonics has led to the deployment of high-precision chip-scale atomic devices [1]. In this talk, we will present in-progress studies at FEMTO-ST Institute, France, for the development of microcellbased microwave and optical atomic clocks, with enhanced stability performances. In the first part, we will talk about the demonstration of CPT-based microwave cell clocks with stability at 1 day in the low 10−12 range [2], made possible thanks to the combination of advanced Ramsey-based interrogation sequences [3] and cells built with low gas permeation windows [4-5]. In the second part, we will discuss the in-progress development of a microcell-based optical frequency reference based on the two-photon transition of Rb atom at 778 nm. An encouraging short-term stability of 3 × 10−13 at 1 s and 3 × 10−14 at 100 s has been recently achieved [6]. Future studies will be briefly discussed.

•Sep 30, 2024•1 citation

A Rb microcell frequency reference based on two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +3 more

Modern communication and navigation systems can significantly benefit from the integration of compact atomic clocks. In this domain, microcell vapor cell optical clocks based on the Rb atom Doppler-free two photon absorption (TPA) at 778 nm are attractive candidates. Best prototypes have shown frequency stability levels of 1.8x10-13 at 1 s, averaging down to the 10-14 range1,2.

•Jun 25, 2024•0 citations

Short-term stability of a microcell optical reference based on the Rb atom two-photon transition at 778 nm

Martin Callejo, Andrei Mursa, Rémy Vicarini +5 more

We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.

arXiv:2407.00841•Journal of the Optical Society of America B•Nov 22, 2024•15 citations

Rb microfabricated cells for a two-photon optical frequency reference

Martin Callejo, Rémy Vicarini, Andrei Mursa +4 more

Miniaturized vapor cell optical clocks based on the use of the two photon absorption transition (TPT) of the Rb atom at 778 nm have recently demonstrated remarkable stability results.

•Jun 18, 2023•0 citations

Two-photon rubidium clock detecting 776 nm fluorescence

River Beard, Kyle W. Martin, John Elgin +2 more

The optical atomic clock based on the 5 S 1/2 → 5 D 5/2 two-photon transition in rubidium is a candidate for a next generation, manufacturable, portable clock that fits in a small size, weight, and power (SWaP) envelope. Here, we report the first two-photon rubidium clock stabilized by detecting 776 nm fluorescence. We also demonstrate the use of a multi-pixel photon counter as a low voltage substitute to a photomultiplier tube in the feedback loop to the clock laser.

arXiv:2510.09560•Optics Express•Jan 25, 2024•19 citations

Double-resonance spectroscopy in Rubidium vapour-cells for high performance and miniature atomic clocks

Mohammadreza Gharavipour, C. Affolderbach, Songbai Kang +1 more

We report our studies on using microwave-optical double-resonance (DR) spectroscopy for a high-performance Rb vapour-cell atomic clock in view of future industrial applications.The clock physics package is very compact with a total volume of only 0.8 dm 3 .It contains a recently in-house developed magnetron-type cavity and a Rb vapour cell.A homedmade frequency-stabilized laser system with an integrated acousto-optical-modulator (AOM)for switching and controlling the light output power-is used as an optical source in a laser head (LH).The LH has the overall volume of 2.5 dm 3 including the laser diode, optical elements, AOM and electronics.In our Rb atomic clock two schemes of continuous-wave DR and Ramsey-DR schemes are used, where the latter one strongly reduces the light-shift effect by separation of the interaction of light and microwave.Applications of the DR clock approach to more radically miniaturized atomic clocks are discussed.

Journal of Physics Conference Series•Jan 1, 2017•2 citations
In this work, we present the in-progress development at FEMTO-ST of a Rb microcell two-photon absorption optical reference. The latter uses an external-cavity diode laser (ECDL) at 778 nm and an AOM for controlling the laser power. The laser beam is sent to a Rb MEMS cell1 and reflected back using a dichroic mirror. TPA fluorescence photons at 420 nm are detected with a photomultiplier. The laser is stabilized onto the Rb87 Fg=2, Fe=4 transition.
The convergence of atomic spectroscopy, MEMS cell technologies and integrated photonics has led to the deployment of high-precision chip-scale atomic devices [1]. In this talk, we will present in-progress studies at FEMTO-ST Institute, France, for the development of microcellbased microwave and optical atomic clocks, with enhanced stability performances. In the first part, we will talk about the demonstration of CPT-based microwave cell clocks with stability at 1 day in the low 10−12 range [2], made possible thanks to the combination of advanced Ramsey-based interrogation sequences [3] and cells built with low gas permeation windows [4-5]. In the second part, we will discuss the in-progress development of a microcell-based optical frequency reference based on the two-photon transition of Rb atom at 778 nm. An encouraging short-term stability of 3 × 10−13 at 1 s and 3 × 10−14 at 100 s has been recently achieved [6]. Future studies will be briefly discussed.
We report on the development and short-term stability characterization of an optical frequency reference based on the spectroscopy of the rubidium two-photon transition at 778 nm in a microfabricated vapor cell. When compared against a 778 nm reference signal extracted from a frequency-doubled cavity-stabilized telecom laser, the short-term stability of the microcell frequency standard is 3.5×10−13τ−1/2 until 200 s, in good agreement with a phase noise level of +43dBrad2/Hz at 1 Hz offset frequency. The two main contributions to the short-term stability of the microcell reference are currently the photon shot noise and the intermodulation effect induced by the laser frequency noise. Retaining a relevant margin of progress, these results show the interest of this spectroscopic approach for the demonstration of high-stability miniaturized optical vapor cell clocks. Such clocks are poised to be highly beneficial for applications in navigation, communications, and metrology.
We report our studies on using microwave-optical double-resonance (DR) spectroscopy for a high-performance Rb vapour-cell atomic clock in view of future industrial applications.The clock physics package is very compact with a total volume of only 0.8 dm 3 .It contains a recently in-house developed magnetron-type cavity and a Rb vapour cell.A homedmade frequency-stabilized laser system with an integrated acousto-optical-modulator (AOM)for switching and controlling the light output power-is used as an optical source in a laser head (LH).The LH has the overall volume of 2.5 dm 3 including the laser diode, optical elements, AOM and electronics.In our Rb atomic clock two schemes of continuous-wave DR and Ramsey-DR schemes are used, where the latter one strongly reduces the light-shift effect by separation of the interaction of light and microwave.Applications of the DR clock approach to more radically miniaturized atomic clocks are discussed.