arXiv:2510.09560 · Optics Express

Two-photon rubidium clock detecting 776 nm fluorescence

River Beard, Kyle W. Martin, John Elgin, Brian L. Kasch, Sean Krzyzewski

Published Jan 25, 2024• 19 citations
arXivHTMLPDF

Abstract

The optical atomic clock based on the 5 S 1/2 → 5 D 5/2 two-photon transition in rubidium is a candidate for a next generation, manufacturable, portable clock that fits in a small size, weight, and power (SWaP) envelope. Here, we report the first two-photon rubidium clock stabilized by detecting 776 nm fluorescence. We also demonstrate the use of a multi-pixel photon counter as a low voltage substitute to a photomultiplier tube in the feedback loop to the clock laser.

DOI
10.1364/oe.513974

Related papers

Compact 780-nm Rb optical clock

Zhendong Chen, Tianyu Liu, Ruoao Yang +9 more

We demonstrated a compact 780 nm rubidium optical clock, which includes an optical frequency standard and an optical frequency comb, with an optical volume of 11.6 liters. Unlike the 778 nm rubidium atomic clocks based on two-photon transition, here, the laser frequency is stabilized to the Rb D2 transition, using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides a high signal to noise ratio and high sensitivity. A nearly 300 MHz microwave signal, whose phase exactly tracks that of the optical frequency standard, is generated via the optical frequency comb, yielding a frequency instability of 1.91 E-13 @1 s and 5.29 E-14 @1000 s in the electronic domain. To the best of our knowledge, this is the most precise frequency stabilization result for the first-excited-state transition of alkali metal atoms to date and represents the first optical clock based on this transition. These results offer a promising approach for the development of portable optical clocks.

arXiv:2501.01826•Physical Review Applied•Nov 24, 2025•6 citations

Compact frequency standard at 1556 nm based on the two-photon transition in rubidium at 778 nm

Michel Poulin, Christine Latrasse, Driss Touahri +2 more

This is a progress report on the realization of a compact and transportable frequency standard at 1556 nm based on a two-photon transition in rubidium at 778 nm. These hyperfine transitions present great metrological interest. They have a narrow theoretical linewidth of 150 kHz when observed with a 1556 nm laser, and their absolute frequency is known with an uncertainty of 5.2 X 10-12. In this experiment, we use a high power 1556 nm DFB laser and reduce its linewidth to the 10 kHz level using optical feedback from a confocal cavity. We generate its second harmonic in a periodically poled LiNbO3 crystal and use this signal to injection-lock a Fabry-Perot laser emitting 42 mW at 778 nm. The slave laser is used to observe the Doppler-free two- photon transitions: two counter-propagating beams excite rubidium atoms which emit a blue fluorescence on resonance. This 420 nm light is detected on the side of the Rb cell with a photomultiplier. Such an optical frequency standard at 1556 nm, standing in the multiwavelength telecommunications systems window, becomes an attractive source for absolute frequency calibration of WDM components, optical spectrum analyzers and wavemeters.

Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE•Oct 8, 1998•0 citations

An optical atomic clock using 4 D J states of rubidium

Alisher Duspayev, C Owens, Bineet Dash +1 more

Abstract We analyze an optical atomic clock using two-photon 5 S 1 / 2 → 4 D J transitions in rubidium. Four one- and two-color excitation schemes to probe the 4 D 3 / 2 and 4 D 5 / 2 fine-structure states are considered in detail. We compare key characteristics of Rb 4 D J and 5 D 5 / 2 two-photon clocks. The 4 D J clock features a high signal-to-noise ratio due to two-photon decay at favorable wavelengths, low dc electric and magnetic susceptibilities, and minimal black-body shifts. Ac Stark shifts from the clock interrogation lasers are compensated by two-color Rabi-frequency matching. We identify a ‘magic’ wavelength near 1060 nm, which allows for in-trap, Doppler-free clock-transition interrogation with lattice-trapped cold atoms. From our analysis of clock statistics and systematics, we project a quantum-noise-limited relative clock stability at the 10 − 13 / τ ( s ) -level, with integration time τ in seconds, and a relative accuracy of ∼ 10 − 13 . We describe a potential architecture for implementing the proposed clock using a single telecom clock laser at 1550 nm, which is conducive to optical communication and long-distance clock comparisons. Our work could be of interest in efforts to realize small and portable Rb clocks and in high-precision measurements of atomic properties of Rb 4 D J -states.

arXiv:2406.09352•Quantum Science and Technology•Sep 6, 2024•7 citations

Progress Towards the Development of a Portable All-optical Atomic Clock Based on a Two-photon Transition in Warm Atomic Vapor

S. Jana, B. K. Sahoo, Arijit Sharma

Optical clocks represent the hallmark of precise timekeeping. The most precise atomic clocks are laboratory-based ones that utilize transitions in the microwave/optical domain of neutral atoms or trapped ions. These clocks define an international time scales, confirm the consistency of physical constants and stimulate the search for new physics outside the Standard Model. The other area is the regime of portable atomic clocks based on warm atomic vapor, which is small, power-efficient and deployable in the field with a variety of civilian applications, including sensing, communication and navigation. Two-photon resonance and optical transition based field deployable clocks present a viable alternative that may outperform current commercial chip scale clocks by at least a factor of 10 in terms of both long-term and short-term stability. For portable clocks, two-photon transitions in alkaline earth metals are of special interest. One of the systematic inaccuracies in the optical reference is eliminated by using counter-propagating laser beams to create Doppler-free spectroscopy. At IIT Tirupati, we are engaged in developing the next generation of atomic vapor based portable frequency standard using two-photon transition in Rubidium (Rb) for atomic sensing and quantum positioning applications. This article discusses the physics behind the two-photon transition in Rubidium atoms suitable for a clock reference. Briefly, it discusses the experimental methodology for realizing an optical clock using warm rubidium vapor.

URSI Regional Conference on Radio Science (URSI-RCRS)•Dec 1, 2022•1 citation

Miniaturized optical frequency reference for next-generation portable optical clocks

Vincent N. Maurice, Zachary L. Newman, Susannah M. Dickerson +7 more

Optical frequency standards, or lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency reference based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. Our optical reference achieves a fractional frequency instability of 2.9×10−12/ τ for averaging times τ less than 103 s, has a volume of ≈35 cm3 and operates on ≈450 mW of electrical power. The advanced optical integration presented here demonstrates a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.

arXiv:2003.13172•Optics Express•Jul 15, 2020•77 citations

Compact Optical Atomic Clock Based on a Two-Photon Transition in Rubidium

Kyle W. Martin, Gretchen R. Phelps, N. Lemke +7 more

Optical frequency standards surpass their microwave counterparts in both stability and accuracy, yet they are often bulky, power-hungry, and unable to operate outside of a well-controlled laboratory environment. Leveraging a two-photon transition in ${}^{87}$Rb vapor and recent advances in fiber frequency combs, the authors build an optical clock to beat the current portable standards, with an architecture that can be made compact and low-power. These results point the way to a real-world optical frequency standard of even higher stability, for applications such as satellite navigation.

arXiv:1903.11231•Physical Review Applied•Jan 18, 2018•178 citations
The optical atomic clock based on the 5 S 1/2 → 5 D 5/2 two-photon transition in rubidium is a candidate for a next generation, manufacturable, portable clock that fits in a small size, weight, and power (SWaP) envelope. Here, we report the first two-photon rubidium clock stabilized by detecting 776 nm fluorescence. We also demonstrate the use of a multi-pixel photon counter as a low voltage substitute to a photomultiplier tube in the feedback loop to the clock laser.
We demonstrated a compact 780 nm rubidium optical clock, which includes an optical frequency standard and an optical frequency comb, with an optical volume of 11.6 liters. Unlike the 778 nm rubidium atomic clocks based on two-photon transition, here, the laser frequency is stabilized to the Rb D2 transition, using modulation transfer spectroscopy. This approach effectively eliminates Doppler background and provides a high signal to noise ratio and high sensitivity. A nearly 300 MHz microwave signal, whose phase exactly tracks that of the optical frequency standard, is generated via the optical frequency comb, yielding a frequency instability of 1.91 E-13 @1 s and 5.29 E-14 @1000 s in the electronic domain. To the best of our knowledge, this is the most precise frequency stabilization result for the first-excited-state transition of alkali metal atoms to date and represents the first optical clock based on this transition. These results offer a promising approach for the development of portable optical clocks.
This is a progress report on the realization of a compact and transportable frequency standard at 1556 nm based on a two-photon transition in rubidium at 778 nm. These hyperfine transitions present great metrological interest. They have a narrow theoretical linewidth of 150 kHz when observed with a 1556 nm laser, and their absolute frequency is known with an uncertainty of 5.2 X 10-12. In this experiment, we use a high power 1556 nm DFB laser and reduce its linewidth to the 10 kHz level using optical feedback from a confocal cavity. We generate its second harmonic in a periodically poled LiNbO3 crystal and use this signal to injection-lock a Fabry-Perot laser emitting 42 mW at 778 nm. The slave laser is used to observe the Doppler-free two- photon transitions: two counter-propagating beams excite rubidium atoms which emit a blue fluorescence on resonance. This 420 nm light is detected on the side of the Rb cell with a photomultiplier. Such an optical frequency standard at 1556 nm, standing in the multiwavelength telecommunications systems window, becomes an attractive source for absolute frequency calibration of WDM components, optical spectrum analyzers and wavemeters.
Abstract We analyze an optical atomic clock using two-photon 5 S 1 / 2 → 4 D J transitions in rubidium. Four one- and two-color excitation schemes to probe the 4 D 3 / 2 and 4 D 5 / 2 fine-structure states are considered in detail. We compare key characteristics of Rb 4 D J and 5 D 5 / 2 two-photon clocks. The 4 D J clock features a high signal-to-noise ratio due to two-photon decay at favorable wavelengths, low dc electric and magnetic susceptibilities, and minimal black-body shifts. Ac Stark shifts from the clock interrogation lasers are compensated by two-color Rabi-frequency matching. We identify a ‘magic’ wavelength near 1060 nm, which allows for in-trap, Doppler-free clock-transition interrogation with lattice-trapped cold atoms. From our analysis of clock statistics and systematics, we project a quantum-noise-limited relative clock stability at the 10 − 13 / τ ( s ) -level, with integration time τ in seconds, and a relative accuracy of ∼ 10 − 13 . We describe a potential architecture for implementing the proposed clock using a single telecom clock laser at 1550 nm, which is conducive to optical communication and long-distance clock comparisons. Our work could be of interest in efforts to realize small and portable Rb clocks and in high-precision measurements of atomic properties of Rb 4 D J -states.
Optical clocks represent the hallmark of precise timekeeping. The most precise atomic clocks are laboratory-based ones that utilize transitions in the microwave/optical domain of neutral atoms or trapped ions. These clocks define an international time scales, confirm the consistency of physical constants and stimulate the search for new physics outside the Standard Model. The other area is the regime of portable atomic clocks based on warm atomic vapor, which is small, power-efficient and deployable in the field with a variety of civilian applications, including sensing, communication and navigation. Two-photon resonance and optical transition based field deployable clocks present a viable alternative that may outperform current commercial chip scale clocks by at least a factor of 10 in terms of both long-term and short-term stability. For portable clocks, two-photon transitions in alkaline earth metals are of special interest. One of the systematic inaccuracies in the optical reference is eliminated by using counter-propagating laser beams to create Doppler-free spectroscopy. At IIT Tirupati, we are engaged in developing the next generation of atomic vapor based portable frequency standard using two-photon transition in Rubidium (Rb) for atomic sensing and quantum positioning applications. This article discusses the physics behind the two-photon transition in Rubidium atoms suitable for a clock reference. Briefly, it discusses the experimental methodology for realizing an optical clock using warm rubidium vapor.
Optical frequency standards, or lasers stabilized to atomic or molecular transitions, are widely used in length metrology and laser ranging, provide a backbone for optical communications and lie at the heart of next-generation optical atomic clocks. Here we demonstrate a compact, low-power optical frequency reference based on the Doppler-free, two-photon transition in rubidium-87 at 778 nm implemented on a micro-optics breadboard. Our optical reference achieves a fractional frequency instability of 2.9×10−12/ τ for averaging times τ less than 103 s, has a volume of ≈35 cm3 and operates on ≈450 mW of electrical power. The advanced optical integration presented here demonstrates a key step towards the development of compact optical clocks and the broad dissemination of SI-traceable wavelength references.
Optical frequency standards surpass their microwave counterparts in both stability and accuracy, yet they are often bulky, power-hungry, and unable to operate outside of a well-controlled laboratory environment. Leveraging a two-photon transition in 87{}^{87}87Rb vapor and recent advances in fiber frequency combs, the authors build an optical clock to beat the current portable standards, with an architecture that can be made compact and low-power. These results point the way to a real-world optical frequency standard of even higher stability, for applications such as satellite navigation.