Abstract A series of quantum locking theories have been proposed to enhance the quantum-noise-limited target sensitivity of the DECi-hertz Interferometer Gravitational wave Observatory. The quantum locking that uses a square completion optimizes the sensitivity across all frequencies. However, a substantial amount of data-series must be post-processed since the square completion is a form of signal processing technique. This paper approaches the optimal sensitivity across all frequencies from an alternative perspective: by optimizing the frequency dependence of a servo gain in a feedback loop. The optimal servo gain is formulated by comparing the alternative method with the square completion method for the same optical setup. This will be shown in general noise issues extending the framework of the quantum locking. We find that the optimal servo gain forms a non-feasible filter but has certain characteristics. We also find that the noise of the measurement signal deteriorates proportionally to the noise measured in the feedback loop when the servo gain is slightly imperfect.
Abstract A series of quantum locking theories have been proposed to enhance the quantum-noise-limited target sensitivity of the DECi-hertz Interferometer Gravitational wave Observatory. The quantum locking that uses a square completion optimizes the sensitivity across all frequencies. However, a substantial amount of data-series must be post-processed since the square completion is a form of signal processing technique. This paper approaches the optimal sensitivity across all frequencies from an alternative perspective: by optimizing the frequency dependence of a servo gain in a feedback loop. The optimal servo gain is formulated by comparing the alternative method with the square completion method for the same optical setup. This will be shown in general noise issues extending the framework of the quantum locking. We find that the optimal servo gain forms a non-feasible filter but has certain characteristics. We also find that the noise of the measurement signal deteriorates proportionally to the noise measured in the feedback loop when the servo gain is slightly imperfect.
Quantum locking using optical spring and homodyne detection has been devised to reduce the quantum noise that limits the sensitivity of the DECIGO, a space-based gravitational-wave antenna in the frequency band around 0.1 Hz for the detection of primordial gravitational waves. The reduction in the upper limit of energy density ΩGW from 2×10−15 to 1×10−16, as inferred from recent observations, necessitates improved sensitivity in the DECIGO to meet its primary science goals. To accurately evaluate the effectiveness of this method, this paper considers a detection mechanism that takes into account the influence of vacuum fluctuations on homodyne detection. In addition, an advanced signal processing method is devised to efficiently utilize signals from each photodetector, and design parameters for this configuration are optimized for the quantum noise. Our results show that this method is effective in reducing quantum noise, despite the detrimental impact of vacuum fluctuations on its sensitivity.
The sensitivity in interferometric measurements such as gravitational-wave detectors is ultimately limited by quantum noise of light. We discuss the use of feedback mechanisms to reduce the quantum effects of radiation pressure. Recent experiments have shown that it is possible to reduce the thermal motion of a mirror by cold damping. The mirror motion is measured with an optomechanical sensor based on a high-finesse cavity, and reduced by a feedback loop. We show that this technique can be extended to lock the mirror at the quantum level. In gravitational-waves interferometers with Fabry-Perot cavities in each arms, it is even possible to use a single feedback mechanism to lock one cavity mirror on the other. This quantum locking greatly improves the sensitivity of the interferometric measurement. It is furthermore insensitive to imperfections such as losses in the interferometer.
We study measurement-based feedback control of a damped harmonic oscillator, motivated by optomechanical and interferometric position measurements, in which feedback is synthesized from a displacement measurement. For a band-limited derivative controller, the loop shapes the mechanical susceptibility and reinjects measurement noise, creating a tradeoff between stabilization and noise amplification. We present a compact classical formulation that isolates this tradeoff in the closed-loop displacement spectrum and identifies the parameters governing resonance suppression versus noise-driven actuation. We then extend the same topology to a quantum-limited position detector, enforcing the imprecision-backaction constraint and introducing finite measurement bandwidth that regularizes high-frequency noise reinjection and adds phase lag in the feedback path. In the high-Q regime we obtain an analytic design rule for the optimal feedback gain at fixed controller and measurement bandwidths and compare it with full-spectrum calculations. The comparison shows that a high mechanical quality factor alone does not guarantee quantitative agreement: the accuracy of the near-resonant approximation depends strongly on the controller and measurement bandwidths. Because finite measurement bandwidth changes both the magnitude and phase of the feedback loop, the analysis separates the near-resonant damping contribution from imprecision-noise reinjection and shows that positive near-resonant feedback damping requires the product of the controller cutoff and measurement bandwidth to exceed the square of the mechanical resonance frequency. Finally, we present a dimensionless map of the gain-optimized high-Q occupation and compare its predictions with full-spectrum optimization. All analytical gains evaluated in this map satisfy the full closed-loop stability criterion for these parameters.
Current interferometric gravitational wave detectors were designed to be limited, in much of their sensitive \nband, by quantum noise in the form of shot noise (at high frequency) or quantum radiation pressure noise \n(at low frequency). In the current observation run (O3), a squeezed light source has been used to \nmanipulate quantum noise and surpass the limits imposed by the circulating laser power by injecting nonclassical states of the electromagnetic field, called squeezed vacuum states, in the interferometer's dark \nport. Recent O3 results show that this technique was able to reduce the shot noise contribution to the \nnoise spectral density by about one half. To surpass the so called standard quantum limit across the entire \nsensitivity band, an even more complex variation of this technique will be implemented, which requires the \nuse of a so called “filter cavity” to reflect the squeezed quantum field and rotate the squeezing angle as a \nfunction of frequency. \nThe performance of this techniques is however severely limited by light losses. One big contributor to \noptical losses is the mismatch between the squeezed vacuum beam, the beam circulating into the \ninterferometer and, in the near future, the filter cavity fundamental transverse spatial mode. \nTo be able to monitor and actively correct mode mismatch, an accurate, online sensing technique is \nneeded. A possible solution consists in the introduction of an Electro-Optic Lens (EOL) that can induce \nradio-frequency sidebands in the Laguerre-Gauss 10 (LG10) transverse mode of the beam. If the \nmodulation frequency is tuned in a way that one sideband is at the cavity LG10 frequency, then the \nresonance breaks the symmetry of the two sidebands and converts phase modulation into amplitude \nmodulation, making it possible to retrieve an error signal directly from the cavity reflected electric field \nwith the same single-element photodetector used for the Pound Drever Hall (PDH) locking technique. This \nerror signal carries information about the magnitude and nature of the mismatch, providing all is needed to \ninform a dedicated feedback loop with a suitable actuator to maintain the mismatch at or below the 1% \nlevel. \nThe goal of this thesis is to demonstrate the technique on a dedicated bench-top experiment employing an \nEOL prototype device. The EOL alignment and working point, as well as the cavity lock parameters were \noptimized in an already existing setup. Simulations and theoretical calculations of the cavity reflected field \nwere performed to evaluate the system non-idealities: both Electro-Optic Modulator (for PDH technique) \nand EOL modulations effects and interactions, as well as some system imperfections were considered. The \nsimulations confirm that this technique requires a stable cavity lock condition, and for this reason an \naccurate study and optimization of the feedback loop parameters was done. In conclusion, a \ncharacterization of the EOL error signal response to different mismatch conditions are presented.
Interferometric detection of gravitational waves at a level of astrophysical interest is expected to require measurement of optical phase differences of < or = 10(-10) rad. A fundamental limit to the phase sensing is the statistics of photon detection--Poisson statistics for light in a coherent state. We have built a laboratory-scale interferometer to achieve and investigate the phase detection sensitivity required for the Laser Interferometer Gravitational-Wave Observatory. With 70 W of circulating power, we have obtained a phase sensitivity of 1.28 x 10(-10) rad/square root(Hz) at frequencies above 600 Hz, limited by quantum noise. Below 600 Hz, excess noise above the quantum limit is seen, and we present our investigations into the sources of this excess. Compared with the results of previous such experiments, the phase sensitivity over the full 100-Hz-10-kHz band of interest has been improved by factors of up to 100, with a factor-of-2.5 improvement in the quantum-limited level.
Quantum fluctuation of light limits the sensitivity of advanced laser interferometric gravitational-wave detectors. It is one of the principal obstacles on the way towards the next-generation gravitational-wave observatories. The envisioned significant improvement of the detector sensitivity requires using quantum non-demolition measurement and back-action evasion techniques, which allow us to circumvent the sensitivity limit imposed by the Heisenberg uncertainty principle. In our previous review article (Danilishin and Khalili in Living Rev Relativ 15:5, 2012 ), we laid down the basic principles of quantum measurement theory and provided the framework for analysing the quantum noise of interferometers. The scope of this paper is to review novel techniques for quantum noise suppression proposed in the recent years and put them in the same framework. Our delineation of interferometry schemes and topologies is intended as an aid in the process of selecting the design for the next-generation gravitational-wave observatories.