Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Sensors

Ultra-High Vacuum Cells Realized by Miniature Ion Pump Using High-Efficiency Plasma Source

Yuichi Kurashima, Atsuhiko Maeda, Naoto Oshima, Taisei Motomura, Takashi Matsumae, Mitsuhiro Watanabe, Hideki Takagi

Published Jun 20, 2024• 4 citations
Publisher

Abstract

In recent years, there has been significant interest in quantum technology, characterized by the emergence of quantum computers boasting immense processing power, ultra-sensitive quantum sensors, and ultra-precise atomic clocks. Miniaturization of quantum devices using cold atoms necessitates the employment of an ultra-high vacuum miniature cell with a pressure of approximately 10−6 Pa or even lower. In this study, we developed an ultra-high vacuum cell realized by a miniature ion pump using a high-efficiency plasma source. Initially, an unsealed miniature ion pump was introduced into a vacuum chamber, after which the ion pump’s discharge current, depending on vacuum pressures, was evaluated. Subsequently, a miniature vacuum cell was fabricated by hermetically sealing the miniature vacuum pump. The cell was successfully evacuated by a miniature ion pump down to an ultra-high vacuum region, which was derived by the measured discharge current. Our findings demonstrate the feasibility of achieving an ultra-high vacuum cell necessary for the operation of miniature quantum devices.

DOI
10.3390/s24124000

Related papers

Wafer-scale micro-knife sealed vacuum cells for quantum devices

Megan Kelleher, Konrad Ziegler, Jeremy Robin +10 more

Abstract Advanced integration technologies greatly enhance the prospects and reliability of practical quantum sensors, atomic clocks, and quantum information technologies. The performance and proliferation of these devices at chip scale is contingent upon developing low leak and low gas permeation vacuum cells using wafer-scale techniques. Here, we demonstrate a novel, low-leak-rate micro-knife bonding approach, enabling the realization of both atomic vapor cells and more complex evacuated atomic beam devices. These devices are fabricated using selective laser etching in a fused silica platform. The vapor cells are mechanically robust exhibiting shear-force strength ∼ 15 MPa, demonstrate long lifetimes ( > 1 year), low residual gas pressures ( ≪ 10 − 3 mbar ) , and leak rates below fine-leak testing sensitivity ( ≪ 2.8 × 10 − 10 mbar ⋅ l s − 1 ). Micro-knife bonding greatly simplifies the fabrication process for complex chip scale atom-beam devices and atomic vapor cells while identifying a path to future chip-scale cold atom devices, improved chip scale atomic clocks, and fieldable dissipation-dilution-limited optomechanics.

arXiv:2602.00390•Quantum Science and Technology•Jul 16, 2026•1 citation

Vacuum characterization of a compact room-temperature trapped ion system

Yuhi Aikyo, Geert Vrijsen, Thomas W. Noel +3 more

We present the design and vacuum performance of a compact room-temperature trapped ion system for quantum computing, consisting of an ultra-high vacuum (UHV) package, a micro-fabricated surface trap, and a small form-factor ion pump. The system is designed to maximize mechanical stability and robustness by minimizing the system size and weight. The internal volume of the UHV package is only ≈2 cm3, a significant reduction in comparison with conventional vacuum chambers used in trapped ion experiments. We demonstrate trapping of 174Yb+ ions in this system and characterize the vacuum level in the UHV package by monitoring both the rates of ion hopping in a double-well potential and ion chain reordering events. The calculated pressure in this vacuum package is ≈2.2×1011 Torr, which is sufficient for the majority of current trapped ion experiments.

arXiv:2007.07950•Applied Physics Letters•Dec 7, 2020•12 citations

Miniaturized vacuum package for magneto-optical trapping of strontium

Julian Pick, Eric Henker, Florian Löwinger +17 more

Quantum sensors, like optical lattice clocks, undergo a continuous development from lab-based towards mobile systems. A key aspect in the miniaturization of the experimental setups is the development of compact atom sources. Conventional atom sources for alkaline-earth-like elements consist of a high-power oven and a six-beam magneto-optical trap (MOT) inside of vacuum chamber with extensive flanges, viewports and electrical feedthroughs. Here we present a highly compact vacuum package utilizing key technologies for future quantum sensor systems: A chip-based low-power atomic oven, a planar grating MOT chip, and a miniaturized vacuum pump all held inside an additively manufactured titanium vacuum chamber, featuring custom-sized vacuum flanges. In this miniaturized setup, spanning a volume of only 750 ml, we trap up to $10^5$ Sr atoms in a MOT, requiring an oven heating power below 1 W.

arXiv:2609.09846•Sep 9, 2026•0 citations

Pumping Dynamics of Cold-Atom Experiments in a Single Vacuum Chamber

Jean-Marc Martin, Satyanarayana Bade, William Dubosclard +4 more

Compact ultracold-atom sensors using a single vacuum chamber have their stability ultimately constrained by vacuum dynamics. To speed evacuation, the straightforward approach is to increase the pumping speed, which implies increasing pump size and sensor volume. This investigation of the dynamics of sputtered ion pumps (SIPs) describes the main physical mechanisms with a nonlinear model for ion-current pump-down in the low-pressure regime. One pumping process suggests that a structured cathode could curtail the increase in pump size, or at least maintain the trapping cross section of the electrode---a result that may be important in the design and development of miniature ion pumps.

arXiv:1912.06848•Physical Review Applied•Jul 18, 2019•7 citations

A highly miniaturized vacuum package for a trapped ion atomic clock

Peter D. D. Schwindt, Yuan‐Yu Jau, Heather L. Partner +6 more

We report on the development of a highly miniaturized vacuum package for use in an atomic clock utilizing trapped ytterbium-171 ions. The vacuum package is approximately 1 cm(3) in size and contains a linear quadrupole RF Paul ion trap, miniature neutral Yb sources, and a non-evaporable getter pump. We describe the fabrication process for making the Yb sources and assembling the vacuum package. To prepare the vacuum package for ion trapping, it was evacuated, baked at a high temperature, and then back filled with a helium buffer gas. Once appropriate vacuum conditions were achieved in the package, it was sealed with a copper pinch-off and was subsequently pumped only by the non-evaporable getter. We demonstrated ion trapping in this vacuum package and the operation of an atomic clock, stabilizing a local oscillator to the 12.6 GHz hyperfine transition of (171)Y b(+). The fractional frequency stability of the clock was measured to be 2 × 10(-11)/τ(1/2).

Review of Scientific Instruments•May 1, 2016•55 citations

Towards Ultra-High Vacuum Operation in a TEM for Quantum-Computer-Enhanced Electron Microscopy

Martino Zanetti, Dominik Hornof, Michael Stanislaus Seifner +2 more

Quantum electron microscopy is an emerging research field at the intersection of electron microscopy, quantum optics, and nanophotonics. Free electrons can serve as powerful quantum probes, on par with photons in their ability to carry and transfer quantum information, generate entanglement within and with a specimen, and reveal previously inaccessible details on nanoscale quantum phenomena [1]. However, quantum experiments are generally highly sensitive to decoherence arising from interactions with residual gas particles, making ultra-high vacuum (UHV) conditions sometimes essential. UHV environments are also required in transmission electron microscopes (TEMs) for the investigation of contamination-sensitive materials [2, 3]. In our project, we aim to combine a trapped-ion quantum computer with a TEM to realise Quantum-Computer-Enhanced Electron Microscopy (QCEM) (www.qcem.info). In this scheme, coherent interactions between free electrons and a trapped ion require vacuum conditions beyond the standard TEM operation [4]. Although UHV-TEM systems have previously been realised [2,3, 5-7], achieving base pressures in the 10⁻⁹ mbar range or better typically involves significant financial investment, long implementation times, and close collaboration with manufacturers. We present a cost-effective, minimally invasive modification to the vacuum system of a JEOL JEM-2100F to reduce the base pressure at the sample position to below 5 × 10⁻⁹ mbar. Our approach is to integrate two additional 50 L/s NEG-ion pumps mounted on flanges near the sample region, with no structural modifications to the microscope. The NEG pumps are integrated into the microscope workflow through controlled activation and regeneration cycles compatible with standard TEM operation. This work represents a practical step toward enabling the realisation of QCEM, and the concept enables a relatively rapid implementation at a moderate cost, which can, in principle, be adapted to any TEM that provides suitable flange access to the sample chamber.

•Apr 20, 2026•0 citations
In recent years, there has been significant interest in quantum technology, characterized by the emergence of quantum computers boasting immense processing power, ultra-sensitive quantum sensors, and ultra-precise atomic clocks. Miniaturization of quantum devices using cold atoms necessitates the employment of an ultra-high vacuum miniature cell with a pressure of approximately 10−6 Pa or even lower. In this study, we developed an ultra-high vacuum cell realized by a miniature ion pump using a high-efficiency plasma source. Initially, an unsealed miniature ion pump was introduced into a vacuum chamber, after which the ion pump’s discharge current, depending on vacuum pressures, was evaluated. Subsequently, a miniature vacuum cell was fabricated by hermetically sealing the miniature vacuum pump. The cell was successfully evacuated by a miniature ion pump down to an ultra-high vacuum region, which was derived by the measured discharge current. Our findings demonstrate the feasibility of achieving an ultra-high vacuum cell necessary for the operation of miniature quantum devices.
Abstract Advanced integration technologies greatly enhance the prospects and reliability of practical quantum sensors, atomic clocks, and quantum information technologies. The performance and proliferation of these devices at chip scale is contingent upon developing low leak and low gas permeation vacuum cells using wafer-scale techniques. Here, we demonstrate a novel, low-leak-rate micro-knife bonding approach, enabling the realization of both atomic vapor cells and more complex evacuated atomic beam devices. These devices are fabricated using selective laser etching in a fused silica platform. The vapor cells are mechanically robust exhibiting shear-force strength ∼ 15 MPa, demonstrate long lifetimes ( > 1 year), low residual gas pressures ( ≪ 10 − 3 mbar ) , and leak rates below fine-leak testing sensitivity ( ≪ 2.8 × 10 − 10 mbar ⋅ l s − 1 ). Micro-knife bonding greatly simplifies the fabrication process for complex chip scale atom-beam devices and atomic vapor cells while identifying a path to future chip-scale cold atom devices, improved chip scale atomic clocks, and fieldable dissipation-dilution-limited optomechanics.
We present the design and vacuum performance of a compact room-temperature trapped ion system for quantum computing, consisting of an ultra-high vacuum (UHV) package, a micro-fabricated surface trap, and a small form-factor ion pump. The system is designed to maximize mechanical stability and robustness by minimizing the system size and weight. The internal volume of the UHV package is only ≈2 cm3, a significant reduction in comparison with conventional vacuum chambers used in trapped ion experiments. We demonstrate trapping of 174Yb+ ions in this system and characterize the vacuum level in the UHV package by monitoring both the rates of ion hopping in a double-well potential and ion chain reordering events. The calculated pressure in this vacuum package is ≈2.2×1011 Torr, which is sufficient for the majority of current trapped ion experiments.
Quantum sensors, like optical lattice clocks, undergo a continuous development from lab-based towards mobile systems. A key aspect in the miniaturization of the experimental setups is the development of compact atom sources. Conventional atom sources for alkaline-earth-like elements consist of a high-power oven and a six-beam magneto-optical trap (MOT) inside of vacuum chamber with extensive flanges, viewports and electrical feedthroughs. Here we present a highly compact vacuum package utilizing key technologies for future quantum sensor systems: A chip-based low-power atomic oven, a planar grating MOT chip, and a miniaturized vacuum pump all held inside an additively manufactured titanium vacuum chamber, featuring custom-sized vacuum flanges. In this miniaturized setup, spanning a volume of only 750 ml, we trap up to 10510^5105 Sr atoms in a MOT, requiring an oven heating power below 1 W.
Compact ultracold-atom sensors using a single vacuum chamber have their stability ultimately constrained by vacuum dynamics. To speed evacuation, the straightforward approach is to increase the pumping speed, which implies increasing pump size and sensor volume. This investigation of the dynamics of sputtered ion pumps (SIPs) describes the main physical mechanisms with a nonlinear model for ion-current pump-down in the low-pressure regime. One pumping process suggests that a structured cathode could curtail the increase in pump size, or at least maintain the trapping cross section of the electrode---a result that may be important in the design and development of miniature ion pumps.
We report on the development of a highly miniaturized vacuum package for use in an atomic clock utilizing trapped ytterbium-171 ions. The vacuum package is approximately 1 cm(3) in size and contains a linear quadrupole RF Paul ion trap, miniature neutral Yb sources, and a non-evaporable getter pump. We describe the fabrication process for making the Yb sources and assembling the vacuum package. To prepare the vacuum package for ion trapping, it was evacuated, baked at a high temperature, and then back filled with a helium buffer gas. Once appropriate vacuum conditions were achieved in the package, it was sealed with a copper pinch-off and was subsequently pumped only by the non-evaporable getter. We demonstrated ion trapping in this vacuum package and the operation of an atomic clock, stabilizing a local oscillator to the 12.6 GHz hyperfine transition of (171)Y b(+). The fractional frequency stability of the clock was measured to be 2 × 10(-11)/τ(1/2).
Quantum electron microscopy is an emerging research field at the intersection of electron microscopy, quantum optics, and nanophotonics. Free electrons can serve as powerful quantum probes, on par with photons in their ability to carry and transfer quantum information, generate entanglement within and with a specimen, and reveal previously inaccessible details on nanoscale quantum phenomena [1]. However, quantum experiments are generally highly sensitive to decoherence arising from interactions with residual gas particles, making ultra-high vacuum (UHV) conditions sometimes essential. UHV environments are also required in transmission electron microscopes (TEMs) for the investigation of contamination-sensitive materials [2, 3]. In our project, we aim to combine a trapped-ion quantum computer with a TEM to realise Quantum-Computer-Enhanced Electron Microscopy (QCEM) (www.qcem.info). In this scheme, coherent interactions between free electrons and a trapped ion require vacuum conditions beyond the standard TEM operation [4]. Although UHV-TEM systems have previously been realised [2,3, 5-7], achieving base pressures in the 10⁻⁹ mbar range or better typically involves significant financial investment, long implementation times, and close collaboration with manufacturers. We present a cost-effective, minimally invasive modification to the vacuum system of a JEOL JEM-2100F to reduce the base pressure at the sample position to below 5 × 10⁻⁹ mbar. Our approach is to integrate two additional 50 L/s NEG-ion pumps mounted on flanges near the sample region, with no structural modifications to the microscope. The NEG pumps are integrated into the microscope workflow through controlled activation and regeneration cycles compatible with standard TEM operation. This work represents a practical step toward enabling the realisation of QCEM, and the concept enables a relatively rapid implementation at a moderate cost, which can, in principle, be adapted to any TEM that provides suitable flange access to the sample chamber.