Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1912.06848 · Physical Review Applied

Pumping Dynamics of Cold-Atom Experiments in a Single Vacuum Chamber

Jean-Marc Martin, Satyanarayana Bade, William Dubosclard, Murtaza Ali Khan, Seungjin Kim, B. M. Garraway, Carlos L. Garrido Alzar

Published Jul 18, 2019• 7 citations
arXivHTMLPDF

Abstract

Compact ultracold-atom sensors using a single vacuum chamber have their stability ultimately constrained by vacuum dynamics. To speed evacuation, the straightforward approach is to increase the pumping speed, which implies increasing pump size and sensor volume. This investigation of the dynamics of sputtered ion pumps (SIPs) describes the main physical mechanisms with a nonlinear model for ion-current pump-down in the low-pressure regime. One pumping process suggests that a structured cathode could curtail the increase in pump size, or at least maintain the trapping cross section of the electrode---a result that may be important in the design and development of miniature ion pumps.

DOI
10.1103/physrevapplied.12.014033

Related papers

A passively pumped vacuum package sustaining cold atoms for more than 200 days

Bethany J. Little, Gregory W. Hoth, Justin Christensen +5 more

Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.

arXiv:2101.01051•AVS Quantum Science•Jul 15, 2021•39 citations

Ultra-High Vacuum Cells Realized by Miniature Ion Pump Using High-Efficiency Plasma Source

Yuichi Kurashima, Atsuhiko Maeda, Naoto Oshima +4 more

In recent years, there has been significant interest in quantum technology, characterized by the emergence of quantum computers boasting immense processing power, ultra-sensitive quantum sensors, and ultra-precise atomic clocks. Miniaturization of quantum devices using cold atoms necessitates the employment of an ultra-high vacuum miniature cell with a pressure of approximately 10−6 Pa or even lower. In this study, we developed an ultra-high vacuum cell realized by a miniature ion pump using a high-efficiency plasma source. Initially, an unsealed miniature ion pump was introduced into a vacuum chamber, after which the ion pump’s discharge current, depending on vacuum pressures, was evaluated. Subsequently, a miniature vacuum cell was fabricated by hermetically sealing the miniature vacuum pump. The cell was successfully evacuated by a miniature ion pump down to an ultra-high vacuum region, which was derived by the measured discharge current. Our findings demonstrate the feasibility of achieving an ultra-high vacuum cell necessary for the operation of miniature quantum devices.

Sensors•Jun 20, 2024•4 citations

Vacuum characterization of a compact room-temperature trapped ion system

Yuhi Aikyo, Geert Vrijsen, Thomas W. Noel +3 more

We present the design and vacuum performance of a compact room-temperature trapped ion system for quantum computing, consisting of an ultra-high vacuum (UHV) package, a micro-fabricated surface trap, and a small form-factor ion pump. The system is designed to maximize mechanical stability and robustness by minimizing the system size and weight. The internal volume of the UHV package is only ≈2 cm3, a significant reduction in comparison with conventional vacuum chambers used in trapped ion experiments. We demonstrate trapping of 174Yb+ ions in this system and characterize the vacuum level in the UHV package by monitoring both the rates of ion hopping in a double-well potential and ion chain reordering events. The calculated pressure in this vacuum package is ≈2.2×1011 Torr, which is sufficient for the majority of current trapped ion experiments.

arXiv:2007.07950•Applied Physics Letters•Dec 7, 2020•12 citations

Characterization of alkali metal dispensers and non-evaporable getter pumps in ultrahigh vacuum systems for cold atomic sensors

David R. Scherer, David B. Fenner, Joel M. Hensley

A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and nonevaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the nonevaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. The authors have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.

arXiv:1203.1202•Journal of Vacuum Science & Technology A Vacuum Surfaces and Films•Oct 9, 2012•32 citations

Stand-alone vacuum cell for compact ultracold quantum technologies

Oliver S. Burrow, Paul F. Osborn, Edward Boughton +5 more

Compact vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress toward a truly portable compact vacuum system; however, size, weight, and power consumption can be prohibitively large, optical access may be limited, and active pumping is often required. Here, we present a centiliter-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fiber. A cold atom demonstrator based on the vacuum cell delivers 107 laser-cooled 87Rb atoms per second, using minimal electrical power. With continuous Rb gas emission, active pumping yields a 10−7 mbar equilibrium pressure, and passive pumping stabilizes to 3×10−6 mbar with a 17 day time constant. A vacuum cell, with no Rb dispensing and only passive pumping, has currently kept a similar pressure for more than 500 days. The passive-pumping vacuum lifetime is several years, which is estimated from short-term He throughput with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.

arXiv:2101.07851•Applied Physics Letters•Sep 20, 2021•47 citations

Effective Slowing and Trapping of Cs Atoms in an Ultrahigh-Vacuum Apparatus

Yuqing Li, Huiying Du, Wang Yunfei +7 more

We report the effective slowing and trapping of Cs atoms in an ultrahigh-vacuum apparatus. The heated Cs atoms in an oven are slowed using a Zeeman slower after the oven chamber and then trapped using a magneto-optical trap in a science chamber. Compared to the traditional vacuum pressure of ~10-7 Pa determined by the vapor pressure of Cs atoms in the oven chamber, the designed cold nipple and differential pumping tube are used between the oven and the oven chamber to achieve a lower vacuum pressure of ~3.6×10-9 Pa. This is beneficial for achieving and maintaining an ultrahigh vacuum in the science chamber. We demonstrate the performance of our apparatus through the effective slowing of Cs atoms and an optimal magneto-optical trap.

Laser & Optoelectronics Progress•Jan 1, 2023•0 citations
Compact ultracold-atom sensors using a single vacuum chamber have their stability ultimately constrained by vacuum dynamics. To speed evacuation, the straightforward approach is to increase the pumping speed, which implies increasing pump size and sensor volume. This investigation of the dynamics of sputtered ion pumps (SIPs) describes the main physical mechanisms with a nonlinear model for ion-current pump-down in the low-pressure regime. One pumping process suggests that a structured cathode could curtail the increase in pump size, or at least maintain the trapping cross section of the electrode---a result that may be important in the design and development of miniature ion pumps.
Compact cold-atom sensors depend on vacuum technology. One of the major limitations to miniaturizing these sensors is the active pumps—typically ion pumps—that are required to sustain the low pressure needed for laser cooling. Although passively pumped chambers have been proposed as a solution to this problem, technical challenges have prevented successful operation at the levels needed for cold-atom experiments. The authors present the first demonstration of a vacuum package successfully independent of ion pumps for more than a week; their vacuum package is capable of sustaining a cloud of cold atoms in a magneto-optical trap (MOT) for greater than 200 days using only non-evaporable getters and a rubidium dispenser. Measurements of the MOT lifetime indicate that the package maintains a pressure of better than 2×10−7 Torr. This result will significantly enable the development of compact atomic sensors, including those sensitive to magnetic fields, where the absence of an ion pump will be advantageous.
In recent years, there has been significant interest in quantum technology, characterized by the emergence of quantum computers boasting immense processing power, ultra-sensitive quantum sensors, and ultra-precise atomic clocks. Miniaturization of quantum devices using cold atoms necessitates the employment of an ultra-high vacuum miniature cell with a pressure of approximately 10−6 Pa or even lower. In this study, we developed an ultra-high vacuum cell realized by a miniature ion pump using a high-efficiency plasma source. Initially, an unsealed miniature ion pump was introduced into a vacuum chamber, after which the ion pump’s discharge current, depending on vacuum pressures, was evaluated. Subsequently, a miniature vacuum cell was fabricated by hermetically sealing the miniature vacuum pump. The cell was successfully evacuated by a miniature ion pump down to an ultra-high vacuum region, which was derived by the measured discharge current. Our findings demonstrate the feasibility of achieving an ultra-high vacuum cell necessary for the operation of miniature quantum devices.
We present the design and vacuum performance of a compact room-temperature trapped ion system for quantum computing, consisting of an ultra-high vacuum (UHV) package, a micro-fabricated surface trap, and a small form-factor ion pump. The system is designed to maximize mechanical stability and robustness by minimizing the system size and weight. The internal volume of the UHV package is only ≈2 cm3, a significant reduction in comparison with conventional vacuum chambers used in trapped ion experiments. We demonstrate trapping of 174Yb+ ions in this system and characterize the vacuum level in the UHV package by monitoring both the rates of ion hopping in a double-well potential and ion chain reordering events. The calculated pressure in this vacuum package is ≈2.2×1011 Torr, which is sufficient for the majority of current trapped ion experiments.
A glass ultrahigh vacuum chamber with rubidium alkali metal dispensers and nonevaporable getter pumps has been developed and used to create a cold atomic sample in a chamber that operates with only passive vacuum pumps. The ion-mass spectrum of evaporated gases from the alkali metal dispenser has been recorded as a function of dispenser current. The efficacy of the nonevaporable getter pumps in promoting and maintaining vacuum has been characterized by observation of the Rb vapor optical absorption on the D2 transition at 780 nm and vacuum chamber pressure rate of rise tests. The authors have demonstrated a sample of laser-cooled Rb atoms in this chamber when isolated and operating without active vacuum pumps.
Compact vacuum systems are key enabling components for cold atom technologies, facilitating extremely accurate sensing applications. There has been important progress toward a truly portable compact vacuum system; however, size, weight, and power consumption can be prohibitively large, optical access may be limited, and active pumping is often required. Here, we present a centiliter-scale ceramic vacuum chamber with He-impermeable viewports and an integrated diffractive optic, enabling robust laser cooling with light from a single polarization-maintaining fiber. A cold atom demonstrator based on the vacuum cell delivers 107 laser-cooled 87Rb atoms per second, using minimal electrical power. With continuous Rb gas emission, active pumping yields a 10−7 mbar equilibrium pressure, and passive pumping stabilizes to 3×10−6 mbar with a 17 day time constant. A vacuum cell, with no Rb dispensing and only passive pumping, has currently kept a similar pressure for more than 500 days. The passive-pumping vacuum lifetime is several years, which is estimated from short-term He throughput with many foreseeable improvements. This technology enables wide-ranging mobilization of ultracold quantum metrology.
We report the effective slowing and trapping of Cs atoms in an ultrahigh-vacuum apparatus. The heated Cs atoms in an oven are slowed using a Zeeman slower after the oven chamber and then trapped using a magneto-optical trap in a science chamber. Compared to the traditional vacuum pressure of ~10-7 Pa determined by the vapor pressure of Cs atoms in the oven chamber, the designed cold nipple and differential pumping tube are used between the oven and the oven chamber to achieve a lower vacuum pressure of ~3.6×10-9 Pa. This is beneficial for achieving and maintaining an ultrahigh vacuum in the science chamber. We demonstrate the performance of our apparatus through the effective slowing of Cs atoms and an optimal magneto-optical trap.