Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Sensors and Actuators A Physical

Analysis of effect of pump light wavelength on the magnetic noise suppression of the SERF co-magnetometer

Qi Yuan, Wenfeng Fan, Zhuo Wang, Haoying Pang, Shimiao Fan, Xiaoping Li, Feng Liu, Wei Quan

Published May 14, 2024• 9 citations
Publisher
DOI
10.1016/j.sna.2024.115471

Related papers

The optimization and stabilization of detuned probe light frequency to suppress electron spin polarization error in SERF co-magnetometer

Yao Wei, Sixun Liu, Feng Liu +3 more

Sensors and Actuators A Physical•Jun 8, 2023•18 citations

Analysis and suppression of the three-axis crosstalk effect in the modulated SERF atomic magnetometer

Lin Li, Junjian Tang, Binbin Zhao +3 more

Measurement•Jun 7, 2023•21 citations

High-precision simultaneous frequency and power stabilization of the pump and probe lasers for SERF co-magnetometers

Zhaoyang Cao, Xinxiu Zhou, Wen-Lei Zhao +2 more

Optics & Laser Technology•Oct 16, 2025•2 citations

Effects of Stochastic Magnetic Noise on the SERF Co‐Magnetometer

Feng Li, Zhuo Wang, Wenfeng Fan +4 more

Abstract Stochastic magnetic field noise has a non‐negligible negative impact on the performance of quantum precision measurement instruments such as spin‐exchange relaxation‐free (SERF) co‐magnetometer in terms of sensitivity and stability. Conventional magnetic field error analysis and suppression methods are not applicable to stochastic magnetic field noise. In this paper, a stochastic model of the SERF co‐magnetometer is proposed to analyze the mechanism of stochastic magnetic field noise. The mean and covariance propagation model of the SERF co‐magnetometer is given based on the stochasticity model and statistical principles. The analysis of simulation experiments reveals that reducing the longitudinal electron spin polarization can somewhat reduce the standard deviation of the system output caused by stochastic magnetic field noise. And the atomic ensembles are most resistant to stochastic magnetic field noise when the electron spin polarization strongly couples with the nuclear spin polarization. Finally, the experiments verified the above conclusions. In conclusion, this paper provides theoretical and experimental support for analyzing and suppressing the effect of stochastic magnetic field noise on the SERF co‐magnetometer, which is of great significance for improving the sensitivity and stability of the measurement.

Advanced Quantum Technologies•Apr 19, 2024•6 citations

Research and suppression of optical pointing noise in SERF magnetometers

Haoran Lv, Bozheng Xing, Bangcheng Han +5 more

Measurement•Mar 27, 2026•0 citations

Comprehensive analysis of the impact of optical magnetic misalignment on the performance of the SERF co-magnetometer

Ze Yu Cai, Lihong Duan, Shimiao Fan +2 more

The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.

Optics Express•Apr 10, 2025•4 citations
Abstract Stochastic magnetic field noise has a non‐negligible negative impact on the performance of quantum precision measurement instruments such as spin‐exchange relaxation‐free (SERF) co‐magnetometer in terms of sensitivity and stability. Conventional magnetic field error analysis and suppression methods are not applicable to stochastic magnetic field noise. In this paper, a stochastic model of the SERF co‐magnetometer is proposed to analyze the mechanism of stochastic magnetic field noise. The mean and covariance propagation model of the SERF co‐magnetometer is given based on the stochasticity model and statistical principles. The analysis of simulation experiments reveals that reducing the longitudinal electron spin polarization can somewhat reduce the standard deviation of the system output caused by stochastic magnetic field noise. And the atomic ensembles are most resistant to stochastic magnetic field noise when the electron spin polarization strongly couples with the nuclear spin polarization. Finally, the experiments verified the above conclusions. In conclusion, this paper provides theoretical and experimental support for analyzing and suppressing the effect of stochastic magnetic field noise on the SERF co‐magnetometer, which is of great significance for improving the sensitivity and stability of the measurement.
The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.