Measurement

Research and suppression of optical pointing noise in SERF magnetometers

Haoran Lv, Bozheng Xing, Bangcheng Han, Wenyi Huang, Xu Shen, Wenhao Zhao, Xiujie Fang, Danyue Ma

Published Mar 27, 2026• 0 citations
Publisher
DOI
10.1016/j.measurement.2026.121315

Related papers

Analysis of effect of pump light wavelength on the magnetic noise suppression of the SERF co-magnetometer

Qi Yuan, Wenfeng Fan, Zhuo Wang +5 more

Sensors and Actuators A Physical•May 14, 2024•9 citations

Analysis and suppression of the three-axis crosstalk effect in the modulated SERF atomic magnetometer

Lin Li, Junjian Tang, Binbin Zhao +3 more

Measurement•Jun 7, 2023•21 citations

Light shift cross-sectional distribution measurement and suppression in SERF atomic magnetometers

Yuhao Wang, Ziqi Yuan, Shudong Lin +4 more

Measurement•Oct 15, 2025•2 citations

Ultra-high consistency multichannel SERF atomic magnetometer based on diffractive optics

Jiajie Li, Ying Liu, Zhen Chai +3 more

Sensors and Actuators A Physical•Nov 24, 2023•15 citations

Comprehensive analysis of the impact of optical magnetic misalignment on the performance of the SERF co-magnetometer

Ze Yu Cai, Lihong Duan, Shimiao Fan +2 more

The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.

Optics Express•Apr 10, 2025•4 citations

Noise reduction in optically pumped magnetometer assemblies

V. Schultze, R.P.J. IJsselsteijn, H.‐G. Meyer

Applied Physics B•May 29, 2010•26 citations
The ultra-sensitive atomic co-magnetometer based on the spin-exchange relaxation-free (SERF) regime is a valuable tool for inertial measurements and fundamental physics research. However, the optical magnetic misalignment effect is a significant source of error in SERF co-magnetometers, limiting their magnetic field suppression ability and long-term stability. This paper establishes a response model of angular velocity and magnetic field for the SERF co-magnetometer. The impact of optical magnetic misalignment on the scale factor, magnetic field amplitude-frequency response, and angular velocity errors caused by magnetic noise is systematically investigated. The results indicate that the scale factor and magnetic field suppression ability decrease as the optical magnetic misalignment angle increases, while the angular velocity errors caused by magnetic noise increase as the misalignment angle increases. Finally, experimental results demonstrate that the optical-magnetic misalignment effect significantly compromises the long-term stability of SERF co-magnetometers, underscoring its substantial influence on the overall performance. This work contributes to understanding the mechanism of optical magnetic misalignment effects on the SERF co-magnetometer and enhances its performance.