Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Sensors and Actuators A Physical

The optimization and stabilization of detuned probe light frequency to suppress electron spin polarization error in SERF co-magnetometer

Yao Wei, Sixun Liu, Feng Liu, Wenfeng Fan, Yueyang Zhai, Wei Quan

Published Jun 8, 2023• 18 citations
Publisher
DOI
10.1016/j.sna.2023.114467

Related papers

Enhancing long-term stability of atomic spin polarization based on data-fusion in SERF co-magnetometer

Zehua Liu, Yifan Yan, Zhuo Wang +3 more

Measurement•Jun 19, 2025•5 citations

High-precision simultaneous frequency and power stabilization of the pump and probe lasers for SERF co-magnetometers

Zhaoyang Cao, Xinxiu Zhou, Wen-Lei Zhao +2 more

Optics & Laser Technology•Oct 16, 2025•2 citations

High sensitivity detuned single-light-source orthogonal pump-probe SERF atomic magnetometer

Yuhao Wang, Ying Liu, Ziqian Yue +4 more

Optics and Lasers in Engineering•Feb 10, 2025•2 citations

Analysis of effect of pump light wavelength on the magnetic noise suppression of the SERF co-magnetometer

Qi Yuan, Wenfeng Fan, Zhuo Wang +5 more

Sensors and Actuators A Physical•May 14, 2024•9 citations

Accurate and fast measurement of alkali-metal and noble-gas atoms spin polarizability based on frequency response in SERF co-magnetometer

Xiujie Fang, Danyue Ma, Tian Zhao +4 more

Measurement•Sep 17, 2023•45 citations

Probe beam influence on spin polarization in spin-exchange relaxation-free co-magnetometers

Yao Wei, Xing Li, Yueyang Zhai +4 more

Abstract Spin-exchange relaxation-free (SERF) co-magnetometers have promising applications in both inertial navigation and fundamental physics experiments. However, the fluctuation in the spin polarization caused by the probe beam has a non-negligible influence on the co-magnetometer signal. In this paper, a theoretical model containing three parameters of the probe beam is established by extending the coupled Bloch equation. Based on this model, the influence of probe power density on the transient and steady-state response of the SERF co-magnetometer is analyzed. According to the transient response model, a new measurement method for transverse optical pumping of the probe beam is proposed. Then, for the steady-state response model, a steady-state error suppression method is suggested by adjusting the degree of circular polarization of the probe beam. Eventually, the suppression method is used to refine the SERF co-magnetometer, achieving a suppression rate of 70.31% in transverse electron spin polarization fluctuations, thus improving the co-magnetometer to a stability of 0.0079∘ h−1. To our knowledge, this is better than what has been reported so far.

Journal of Physics D Applied Physics•Feb 20, 2023•5 citations
Abstract Spin-exchange relaxation-free (SERF) co-magnetometers have promising applications in both inertial navigation and fundamental physics experiments. However, the fluctuation in the spin polarization caused by the probe beam has a non-negligible influence on the co-magnetometer signal. In this paper, a theoretical model containing three parameters of the probe beam is established by extending the coupled Bloch equation. Based on this model, the influence of probe power density on the transient and steady-state response of the SERF co-magnetometer is analyzed. According to the transient response model, a new measurement method for transverse optical pumping of the probe beam is proposed. Then, for the steady-state response model, a steady-state error suppression method is suggested by adjusting the degree of circular polarization of the probe beam. Eventually, the suppression method is used to refine the SERF co-magnetometer, achieving a suppression rate of 70.31% in transverse electron spin polarization fluctuations, thus improving the co-magnetometer to a stability of 0.0079∘ h−1. To our knowledge, this is better than what has been reported so far.