Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Optics Express

Sensitivity improvement of a single-NV diamond magnetometer using a chiral waveguide

Kosuke Takada, Ryota Katsumi, Takashi Yatsui

Published Dec 18, 2023• 4 citations
Publisher

Abstract

A single nitrogen-vacancy (NV) center in diamond is utilized to perform nanoscale magnetic measurements. However, the low contrast and poor collection efficiency of spin-dependent emitted photons limited the instrument sensitivity to approximately several nT/Hz. Here, we design a diamond magnetometer based on a chiral waveguide. We numerically demonstrate that the proposed device achieves a sensitivity of 170 pT/Hz owing to near-unity contrast and efficient photon collection. We also confirm that the device sensitivity is robust against position misalignment and dipole misorientation of an NV center. The proposed approach will enable the construction of a highly-sensitive magnetometer with high spatial resolution.

DOI
10.1364/oe.509860

Related papers

Design of an ultra-sensitive and miniaturized diamond NV magnetometer based on a nanocavity structure

Ryota Katsumi, Masaki Sekino, Takashi Yatsui

Abstract The ensemble of nitrogen-vacancy (NV) centers in diamond allows for the potential realization of the sensitive magnetometers by leveraging their excellent spin properties. However, the NV-based magnetometers are limited by their experimental magnetic field sensitivity owing to its inefficient photon collection. Moreover, they are a disadvantage to the reduced spatial resolution and excessive excitation power. To overcome these issues, we propose a ultra-sensitive diamond magnetometer based on nanocavities. The device structure can attain a high collective efficiency and enhance the photon emission intensity of the NV ensemble. This device can allow the efficient photon collection even when considering the positional distribution of the NV centers. Our theoretical analysis indicates that the minimum expected sensitivity is 60 fT/ H z . The proposed design can achieve a volume-normalized sensitivity of 0.92 aT/ H z c m − 3 along with the required power of 7 μW, both of which are superior to those of bulk diamond. The proposed approach offers a promising route towards highly sensitive and energy-efficient magnetometers.

Japanese Journal of Applied Physics•Jul 4, 2022•13 citations

Improving the sensitivity of diamond NV center ensemble magnetometer based on microsphere

Yangyang Zhou, Jiong Tang, Bingxu Ma +1 more

Diamond nitrogen-vacancy (NV) center ensemble magnetometer is a novel solid quantum magnetometer with high sensitivity and high spatial resolution, which can be used at normal temperature and pressure. However, the low fluorescence collection efficiency of the magnetometer in confocal optical system hinders further improvement in sensitivity. To solve the problem, based on silica microspheres, we propose a method to enhance the excitation and collection efficiency of NV center ensemble in massive diamond. Experimental results show, compared with the NV diamond magnetometer without microspheres, the photon collection efficiency of NV diamond magnetometer coated with a layer of microspheres is increased by 110%. Thus, the sensitivity of the NV center magnetometer is increased by 4 times to 5.3μT/√Hz.

International Conference on Optical and Photonic Engineering (icOPEN)•Feb 5, 2025•0 citations

A Highly Sensitive Diamond NV Magnetometer Using Ramsey Interferometry with a Short Sensor-to-Sample Distance

Yuta Araki, Takeharu Sekiguchi, Yuji Hatano +11 more

In this study, we developed a diamond quantum magnetometer based on Ramsey interferometry with a short sensor-to-sample distance. Conventional biomagnetic sensors with ensemble nitrogen-vacancy centers using continuous-wave optically detected magnetic resonance and Ramsey methods typically rely on watt-level lasers to achieve high sensitivity, resulting in thermal issues. In contrast, by employing the light-trapping diamond waveguide technique in a high-pressure and high-temperature diamond sample treated with electron beam irradiation, we obtained a high photon conversion efficiency of 9.5%, enabling us to simultaneously achieve a high sensitivity of 2.93(7) pT/Hz^1/2 in the 100-400 Hz frequency range and a minimal temperature increase of only approximately 13 K at a low laser power of 210 mW. Using a dry phantom designed to mimic magnetoencephalography signals, we measured a weak magnetic field of 77.7(2) pT without signal averaging at a sensor-to-sample distance of 2.5 mm. This short-distance measurement prevents severe spatial signal attenuation, yielding a high signal-to-noise ratio. The development here is crucial for practical biomagnetic applications based on Ramsey interferometry.

quant-pharXiv:2603.13754•Mar 17, 2026

High-Sensitivity Magnetometry Based on Quantum Beats in Diamond Nitrogen-Vacancy Centers

Kejie Fang, Víctor M. Acosta, Charles Santori +5 more

We demonstrate an absolute magnetometer based on quantum beats in the ground state of nitrogen-vacancy centers in diamond. We show that, by eliminating the dependence of spin evolution on the zero-field splitting D, the magnetometer is immune to temperature fluctuation and strain inhomogeneity. We apply this technique to measure low-frequency magnetic field noise by using a single nitrogen-vacancy center located within 500 nm of the surface of an isotopically pure (99.99% 12C) diamond. The photon-shot-noise limited sensitivity achieves 38 nT/sqrt[Hz] for 4.45 s acquisition time, a factor of sqrt[2] better than the implementation which uses only two spin levels. For long acquisition times (>10 s), we realize up to a factor of 15 improvement in magnetic sensitivity, which demonstrates the robustness of our technique against thermal drifts. Applying our technique to nitrogen-vacancy center ensembles, we eliminate dephasing from longitudinal strain inhomogeneity, resulting in a factor of 2.3 improvement in sensitivity.

arXiv:1212.1495•Physical Review Letters•Mar 26, 2013•160 citations

Wideband microwave resonator for NV center vector magnetometry

S. V. Bolshedvorskii, E. A. Koreshin, V. V. Soshenko +10 more

The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about \[{1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;\]. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.

quant-pharXiv:2610.13379•Oct 12, 2026

Multicone Diamond Waveguides for Nanoscale Quantum Sensing

Tianqi Zhu, J. Rhensius, Konstantin Herb +4 more

The long-lived electronic spin of the nitrogen-vacancy (NV) center in diamonds is a promising quantum sensor for detecting nanoscopic magnetic and electric fields in various environments. However, the poor signal-to-noise ratio (SNR) of prevalent optical spin-readout techniques presents a critical challenge in improving measurement sensitivity. Here, we address this limitation by coupling individual NVs to optimized diamond nanopillars, thereby enhancing the collection efficiency of fluorescence. Guided by near-field optical simulations, we predict improved performance for tall (≥5 μm) pillars with tapered sidewalls. This is subsequently verified by fabricating and characterizing a representative set of structures using a newly developed nanofabrication process. We observe increased SNR for optimized devices, owing to improved emission collimation and directionality. Promisingly, these devices are compatible with low-numerical-aperture collection optics and a reduced tip radius, reducing experimental overhead and facilitating improved spatial resolution for scanning applications.

arXiv:2306.02966•Nano Letters•Nov 7, 2023•20 citations
A single nitrogen-vacancy (NV) center in diamond is utilized to perform nanoscale magnetic measurements. However, the low contrast and poor collection efficiency of spin-dependent emitted photons limited the instrument sensitivity to approximately several nT/Hz. Here, we design a diamond magnetometer based on a chiral waveguide. We numerically demonstrate that the proposed device achieves a sensitivity of 170 pT/Hz owing to near-unity contrast and efficient photon collection. We also confirm that the device sensitivity is robust against position misalignment and dipole misorientation of an NV center. The proposed approach will enable the construction of a highly-sensitive magnetometer with high spatial resolution.
Abstract The ensemble of nitrogen-vacancy (NV) centers in diamond allows for the potential realization of the sensitive magnetometers by leveraging their excellent spin properties. However, the NV-based magnetometers are limited by their experimental magnetic field sensitivity owing to its inefficient photon collection. Moreover, they are a disadvantage to the reduced spatial resolution and excessive excitation power. To overcome these issues, we propose a ultra-sensitive diamond magnetometer based on nanocavities. The device structure can attain a high collective efficiency and enhance the photon emission intensity of the NV ensemble. This device can allow the efficient photon collection even when considering the positional distribution of the NV centers. Our theoretical analysis indicates that the minimum expected sensitivity is 60 fT/ H z . The proposed design can achieve a volume-normalized sensitivity of 0.92 aT/ H z c m − 3 along with the required power of 7 μW, both of which are superior to those of bulk diamond. The proposed approach offers a promising route towards highly sensitive and energy-efficient magnetometers.
Diamond nitrogen-vacancy (NV) center ensemble magnetometer is a novel solid quantum magnetometer with high sensitivity and high spatial resolution, which can be used at normal temperature and pressure. However, the low fluorescence collection efficiency of the magnetometer in confocal optical system hinders further improvement in sensitivity. To solve the problem, based on silica microspheres, we propose a method to enhance the excitation and collection efficiency of NV center ensemble in massive diamond. Experimental results show, compared with the NV diamond magnetometer without microspheres, the photon collection efficiency of NV diamond magnetometer coated with a layer of microspheres is increased by 110%. Thus, the sensitivity of the NV center magnetometer is increased by 4 times to 5.3μT/√Hz.
In this study, we developed a diamond quantum magnetometer based on Ramsey interferometry with a short sensor-to-sample distance. Conventional biomagnetic sensors with ensemble nitrogen-vacancy centers using continuous-wave optically detected magnetic resonance and Ramsey methods typically rely on watt-level lasers to achieve high sensitivity, resulting in thermal issues. In contrast, by employing the light-trapping diamond waveguide technique in a high-pressure and high-temperature diamond sample treated with electron beam irradiation, we obtained a high photon conversion efficiency of 9.5%, enabling us to simultaneously achieve a high sensitivity of 2.93(7) pT/Hz^1/2 in the 100-400 Hz frequency range and a minimal temperature increase of only approximately 13 K at a low laser power of 210 mW. Using a dry phantom designed to mimic magnetoencephalography signals, we measured a weak magnetic field of 77.7(2) pT without signal averaging at a sensor-to-sample distance of 2.5 mm. This short-distance measurement prevents severe spatial signal attenuation, yielding a high signal-to-noise ratio. The development here is crucial for practical biomagnetic applications based on Ramsey interferometry.
We demonstrate an absolute magnetometer based on quantum beats in the ground state of nitrogen-vacancy centers in diamond. We show that, by eliminating the dependence of spin evolution on the zero-field splitting D, the magnetometer is immune to temperature fluctuation and strain inhomogeneity. We apply this technique to measure low-frequency magnetic field noise by using a single nitrogen-vacancy center located within 500 nm of the surface of an isotopically pure (99.99% 12C) diamond. The photon-shot-noise limited sensitivity achieves 38 nT/sqrt[Hz] for 4.45 s acquisition time, a factor of sqrt[2] better than the implementation which uses only two spin levels. For long acquisition times (>10 s), we realize up to a factor of 15 improvement in magnetic sensitivity, which demonstrates the robustness of our technique against thermal drifts. Applying our technique to nitrogen-vacancy center ensembles, we eliminate dephasing from longitudinal strain inhomogeneity, resulting in a factor of 2.3 improvement in sensitivity.
The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about 1.2 nT/Hz  {1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;1.2 nT/Hz​. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.
The long-lived electronic spin of the nitrogen-vacancy (NV) center in diamonds is a promising quantum sensor for detecting nanoscopic magnetic and electric fields in various environments. However, the poor signal-to-noise ratio (SNR) of prevalent optical spin-readout techniques presents a critical challenge in improving measurement sensitivity. Here, we address this limitation by coupling individual NVs to optimized diamond nanopillars, thereby enhancing the collection efficiency of fluorescence. Guided by near-field optical simulations, we predict improved performance for tall (≥5 μm) pillars with tapered sidewalls. This is subsequently verified by fabricating and characterizing a representative set of structures using a newly developed nanofabrication process. We observe increased SNR for optimized devices, owing to improved emission collimation and directionality. Promisingly, these devices are compatible with low-numerical-aperture collection optics and a reduced tip radius, reducing experimental overhead and facilitating improved spatial resolution for scanning applications.