arXiv:2610.13379
Wideband microwave resonator for NV center vector magnetometry
S. V. Bolshedvorskii, E. A. Koreshin, V. V. Soshenko, I. S. Cojocaru, S. M. Drofa, P. G. Vilyuzhanina, N. I. Salangin, A. M. Kozodaev, A. Chernyavskiy, A. N. Smolyaninov, P. V. Kapitanova, S. Ya. Kilin, A. V. Akimov
Abstract
The nitrogen-vacancy (NV) color center in diamond has found applications in magnetometry across various geometrical scales. In particular, vector magnetometry using hand-held devices with low power consumption is of interest for mobile and geological applications. However, such a device requires efficient driving of the four different orientations of the NV center, thus placing demands on a broadband microwave resonator that provides a uniform and highly insensitive microwave magnetic field at the resonance frequencies of the NV centers. Here, we propose a unique planar resonator design that enables efficient driving of all four orientations of NV color centers over a 100 MHz range with only 0.5 W of microwave input power and 250 mW of laser power, allowing vector magnetic field measurements. Using the planar resonator to drive NV centers in diamond, a compact vector magnetometer was fabricated and experimentally studied. The sensitivity of the device is about \[{1.2\text{ nT}}/{\sqrt{\text{Hz}}}\;\]. While this is not a record sensitivity for diamond-based magnetometers, this device occupies its own niche as a compact hand-held magnetometer.
AI Summary
NV-center vector magnetometry requires microwave excitation of the four crystallographic NV orientations, whose resonance frequencies split in an applied magnetic field. For compact, low-power instruments, the microwave structure must provide effective driving across these frequencies while maintaining a sufficiently uniform microwave magnetic field. This paper addresses that hardware requirement with a planar broadband microwave resonator intended for hand-held vector magnetometers, including mobile and geological applications. The proposed resonator supports excitation of all four NV orientations over a $100\,\mathrm{MHz}$ frequency range. The abstract reports operation with $0.5\,\mathrm{W}$ of microwave input power and $250\,\mathrm{mW}$ of laser power. The resonator is incorporated into a compact diamond-based vector magnetometer, which is fabricated and experimentally studied. The reported device sensitivity is approximately $1.2\,\mathrm{nT}/\sqrt{\mathrm{Hz}}$. These results establish an experimental implementation rather than only a proposed resonator geometry. The stated scope is a compact, hand-held instrument, not record-setting magnetic sensitivity; the abstract explicitly notes that the sensitivity is below the best demonstrated for diamond-based magnetometers. Only the title and abstract are available here, so the resonator geometry, measured field uniformity, sensitivity measurement protocol, usable magnetic-field range, and vector-reconstruction accuracy cannot be assessed. The quoted microwave and optical powers also do not specify the instrument’s total electrical power consumption.
Written by gpt-6.1-sol from the abstract only. Automated: it can be wrong.