Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Development and characterization of a linear ion trap for an improved optical clock performance

T. Burgermeister

Published Jan 1, 2019• 3 citations
Publisher

Abstract

Single ion frequency standards have demonstrated in several experiments excellent results and are approaching fractional frequency uncertainties of 10^-18. As dominant contributions to the uncertainty are linked to the ion trap properties a further reduction would be possible by an improved ion trap. Due to the interrogation of a single ion these frequency standards are currently limited by the intrinsically low signal-to-noise ratio and require long averaging times on the order of several days. This limitation is critical for various applications that require a high frequency resolution on short timescales. One possibility to improve the clock stability is to increase the number of clock ions. However, this approach further increases the requirements for the ion trap. Therefore, for the realization of a multi-ion clock that aims at simultaneously reducing the frequency stability and uncertainty the control over the characteristics of the ion trap is crucial. This thesis continues previous work towards the realization of a multi-ion optical clock based on ion Coulomb crystals of 115In+ ions which are sympathetically cooled by 172Yb+ ions. The existing design for a segmented linear ion trap has been refined and a reliable trap manufacturing process for a trap based on gold coated aluminium nitride wafers has been developed. Manufacturing tolerances below 10 μm allowed to reduce the axial micromotion amplitudes substantially. For a region of more than 300 μm the uncertainty contribution of the three-dimensional micromotion amplitude is shown to be below 10^-19. Additionally the radial ion heating rate of the trap has been measured to be 1.1 phonons/s for a trap frequency of 490 kHz. The time dilation shift due to the heating rate on the radial trap axis is found to be (2.1 ± 0.3) x 10^-20 1/s. The trap design has also been optimized for a low trap temperature rise due to the applied rf voltage. Trap temperature measurements with Pt100 sensors installed on the trap showed a maximum temperature increase of 1.21 K at an rf voltage amplitude of 1 kV. By comparing the measurement results to FEM simulations the uncertainty contribution of the trap temperature to the black-body radiation shift has been deduced to be 2.4 x 10^-20. As the ion trap provides a high level of control on Coulomb crystals it also provides an ideal test bed for studying atomic many-body systems. This work presents results of the investigations on topological defects in two-dimensional Coulomb crystals. The emphasis was placed on the effects of mass defects and external electric fields on the stability of the topological defects. It is shown that these effects can be used to manipulate and create topological defects deterministically.

DOI
10.15488/5160

Related papers

Spectroscopic characterization of ion motion for an optical clock based on Coulomb crystals

Keller, Jonas

Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.

•Jan 1, 2015•5 citations

Evaluation of trap-induced systematic frequency shifts for a multi-ion optical clock at the 10−19level

Jonas Keller, T. Burgermeister, Dimitri Kalincev +2 more

In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .

arXiv:1512.05677•Journal of Physics Conference Series•Jun 1, 2016•29 citations

Optical clocks based on linear ion chains with high stability and accuracy

Jonas Keller, Dimitri Kalincev, T. Burgermeister +5 more

Trapped-ion optical clocks are capable of achieving systematic fractional frequency uncertainties of $10^{-18}$ and possibly below. However, the stability of current ion clocks is fundamentally limited by the weak signal of single-ion interrogation. We present an operational, versatile platform for extending clock spectroscopy to arrays of Coulomb crystals consisting of several tens of ions, while allowing systematic shifts as low as $10^{-19}$. The concept is applicable to all clock transitions with low differential electric quadrupole moments. We observe 3D excess micromotion amplitudes of all individual ions inside a Coulomb crystal with nm resolution and prove that the related frequency shifts can be controlled simultaneously at the $10^{-19}$ level. Using this method, we demonstrate regions of $400$ $\mu$m and $2$ mm length in our trap array with time dilation shifts due to micromotion close to $1\times10^{-19}$ and below $10^{-18}$, respectively. Further measurements of the trapping environment and cooling dynamics calculations for mixed In${}^+$ / Yb${}^+$ crystals show that achievable clock uncertainties due to multi-ion operation in our setup are below $1\times10^{-19}$. This work will enable clock operation with multiple ions and open up the possibility of new interrogation schemes which allow optical clock stabilities beyond classical limits.

•Dec 6, 2017•5 citations

Sub-kelvin temperature management in ion traps for optical clocks

T. Nordmann, Alexandre Didier, M. Doležal +3 more

The uncertainty of the ac Stark shift due to thermal radiation represents a major contribution to the systematic uncertainty budget of state-of-the-art optical atomic clocks. In the case of optical clocks based on trapped ions, the thermal behavior of the rf-driven ion trap must be precisely known. This determination is even more difficult when scalable linear ion traps are used. Such traps enable a more advanced control of multiple ions and have become a platform for new applications in quantum metrology, simulation, and computation. Nevertheless, their complex structure makes it more difficult to precisely determine its temperature in operation and thus the related systematic uncertainty. We present here scalable linear ion traps for optical clocks, which exhibit very low temperature rise under operation. We use a finite-element model refined with experimental measurements to determine the thermal distribution in the ion trap and the temperature at the position of the ions. The trap temperature is investigated at different rf-drive frequencies and amplitudes with an infrared camera and integrated temperature sensors. We show that for typical trapping parameters for In+, Al+, Lu+, Ca+, Sr+, or Yb+ ions, the temperature rise at the position of the ions resulting from rf heating of the trap stays below 700 mK and can be controlled with an uncertainty on the order of a few 100 mK maximum. The corresponding uncertainty of the trap-related blackbody radiation shift is in the low 10−19 and even 10−20 regime for 171Yb+(E3) and 115In+, respectively.

arXiv:2008.04231•Review of Scientific Instruments•Nov 1, 2020•15 citations

Controlling systematic frequency uncertainties at the 10−19 level in linear Coulomb crystals

Jonas Keller, T. Burgermeister, Dimitri Kalincev +5 more

Trapped ions are ideally suited for precision spectroscopy, as is evident from the remarkably low systematic uncertainties of single-ion clocks. The major weakness of these clocks is the long averaging time, necessitated by the low signal of a single atom. An increased number of ions can overcome this limitation and allow for the implementation of novel clock schemes. However, this presents the challenge to maintain the excellent control over systematic shifts of a single particle in spatially extended and strongly coupled many-body systems. We measure and deduce systematic frequency uncertainties related to spectroscopy with ion chains in an rf trap array designed for precision spectroscopy on simultaneously trapped ion ensembles. For the example of an ${\mathrm{In}}^{+}$ clock, sympathetically cooled with ${\mathrm{Yb}}^{+}$ ions, we show in our system that the expected systematic frequency uncertainties related to multi-ion operation can be below $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$. Our results pave the way to advanced spectroscopy schemes such as entangled clock spectroscopy and cascaded clock operation.

arXiv:1803.08248•Physical Review A•Jan 7, 2019•69 citations

Probing Time Dilation in Coulomb Crystals in a High-Precision Ion Trap

J. Keller, D. Kalincev, T. Burgermeister +5 more

Optical clocks based on trapped ions can achieve systematic frequency uncertainties below 10${}^{\ensuremath{-}18}$, enabling relativistic geodesy and precise tests of fundamental physics. However, today's single-ion clocks require averaging times of over a week to resolve frequencies at this level, and no multi-ion clock has been implemented, due to difficulties in controlling ion motion. The authors present an ion-trap array that confines up to 100 clock ions with time-dilation shifts in the low-10${}^{\ensuremath{-}19}$ range, and measure the driven motion of individual ions within an ion crystal. These results point to the next generation of ion clocks, and the realization of clock schemes that have languished.

arXiv:1712.02335•Physical Review Applied•Jan 7, 2019•47 citations
Single ion frequency standards have demonstrated in several experiments excellent results and are approaching fractional frequency uncertainties of 10^-18. As dominant contributions to the uncertainty are linked to the ion trap properties a further reduction would be possible by an improved ion trap. Due to the interrogation of a single ion these frequency standards are currently limited by the intrinsically low signal-to-noise ratio and require long averaging times on the order of several days. This limitation is critical for various applications that require a high frequency resolution on short timescales. One possibility to improve the clock stability is to increase the number of clock ions. However, this approach further increases the requirements for the ion trap. Therefore, for the realization of a multi-ion clock that aims at simultaneously reducing the frequency stability and uncertainty the control over the characteristics of the ion trap is crucial. This thesis continues previous work towards the realization of a multi-ion optical clock based on ion Coulomb crystals of 115In+ ions which are sympathetically cooled by 172Yb+ ions. The existing design for a segmented linear ion trap has been refined and a reliable trap manufacturing process for a trap based on gold coated aluminium nitride wafers has been developed. Manufacturing tolerances below 10 μm allowed to reduce the axial micromotion amplitudes substantially. For a region of more than 300 μm the uncertainty contribution of the three-dimensional micromotion amplitude is shown to be below 10^-19. Additionally the radial ion heating rate of the trap has been measured to be 1.1 phonons/s for a trap frequency of 490 kHz. The time dilation shift due to the heating rate on the radial trap axis is found to be (2.1 ± 0.3) x 10^-20 1/s. The trap design has also been optimized for a low trap temperature rise due to the applied rf voltage. Trap temperature measurements with Pt100 sensors installed on the trap showed a maximum temperature increase of 1.21 K at an rf voltage amplitude of 1 kV. By comparing the measurement results to FEM simulations the uncertainty contribution of the trap temperature to the black-body radiation shift has been deduced to be 2.4 x 10^-20. As the ion trap provides a high level of control on Coulomb crystals it also provides an ideal test bed for studying atomic many-body systems. This work presents results of the investigations on topological defects in two-dimensional Coulomb crystals. The emphasis was placed on the effects of mass defects and external electric fields on the stability of the topological defects. It is shown that these effects can be used to manipulate and create topological defects deterministically.
Laser-cooled, trapped ions are among the most successful candidates for an optical frequency standard, with fractional frequency uncertainties approaching the low 10 -18 range.However, current implementations of optical ion clocks are based on a single reference ion, which results in an intrinsically low signal-to-noise ratio.Averaging times of several days are necessary for resolving the transition frequency well enough to benefit from these low systematic uncertainties.In order to overcome this impediment to applications, the averaging can be performed more quickly by interrogating an ensemble of ions simultaneously.Due to their mutual repulsion, these ions can be confined by a common trapping potential, in which they arrange in crystalline structures (Coulomb crystals).The technical challenge of this approach is to preserve the excellent systematic uncertainties obtainable with a single ion.This work contributes to the approach of using 115 In + / 172 Yb + Coulomb crystals as the reference for an optical clock.Two ultra-stable cavities for the stabilization of spectroscopy lasers have been set up.With a simple setup, a diode laser has been stabilized to σ y (1 s) = 6 × 10 -16 .The vibration sensitivity of a simple 30 cm long spacer has been measured, showing that a cavity using this spacer can provide a fractional frequency instability of σ y = 1 × 10 -16 for times > 30 ms, sufficient to operate a clock based on 100 115 In + ions at its quantum projection noise limit of 7.2 × 10 -17 / τ /s.Frequency shifts resulting from time dilation due to ion motion are among the limiting contributions in current ion frequency standards.A spectroscopy laser has been set up in order to characterize the motion of Coulomb crystals by interrogating a narrow transition in 172 Yb + .Spatially resolved state detection with an EMCCD camera allows multiple ions to be interrogated simultaneously.Groundstate cooling of two modes in a single ion allowed the determination of heating rates below 2 s -1 at secular frequencies around 500 kHz.Three micromotion compensation techniques have been characterized in terms of their resolution and applicability during clock operation.A new model was developed for the photon-correlation technique to allow quantitative evaluation in the common regime of comparable drive frequency and linewidth.It was experimentally verified in a comparison with resolved sideband measurements.Both the photon-correlation and the parametric excitation method were shown capable of micromotion compensation with a resulting fractional frequency uncertainty well below 10 -19 .Overall, it has been shown that the motional frequency shift contributions due to external heating, secular motion and micromotion in a single 115 In + ion can each be controlled at a level of 10 -19 in the present setup and the foundation has been laid to extend these measurements to multiple ions.
In order to improve the short-term stability of trapped-ion optical clocks, we are developing a frequency standard based on 115 In + / 172 Yb + Coulomb crystals. For this purpose, we have developed scalable segmented Paul traps which allow a high level of control for multiple ion ensembles. In this article, we detail on our recent results regarding the reduction of the leading sources of frequency uncertainty introduced by the ion trap: 2nd-order Doppler shifts due to micromotion and the heating of secular motion, as well as the black-body radiation shift due to warming of the trap. We show that the fractional frequency uncertainty due to each of these effects can be reduced to well below 10 -19 .
Trapped-ion optical clocks are capable of achieving systematic fractional frequency uncertainties of 10−1810^{-18}10−18 and possibly below. However, the stability of current ion clocks is fundamentally limited by the weak signal of single-ion interrogation. We present an operational, versatile platform for extending clock spectroscopy to arrays of Coulomb crystals consisting of several tens of ions, while allowing systematic shifts as low as 10−1910^{-19}10−19. The concept is applicable to all clock transitions with low differential electric quadrupole moments. We observe 3D excess micromotion amplitudes of all individual ions inside a Coulomb crystal with nm resolution and prove that the related frequency shifts can be controlled simultaneously at the 10−1910^{-19}10−19 level. Using this method, we demonstrate regions of 400400400 μ\muμm and 222 mm length in our trap array with time dilation shifts due to micromotion close to 1×10−191\times10^{-19}1×10−19 and below 10−1810^{-18}10−18, respectively. Further measurements of the trapping environment and cooling dynamics calculations for mixed In+{}^++ / Yb+{}^++ crystals show that achievable clock uncertainties due to multi-ion operation in our setup are below 1×10−191\times10^{-19}1×10−19. This work will enable clock operation with multiple ions and open up the possibility of new interrogation schemes which allow optical clock stabilities beyond classical limits.
The uncertainty of the ac Stark shift due to thermal radiation represents a major contribution to the systematic uncertainty budget of state-of-the-art optical atomic clocks. In the case of optical clocks based on trapped ions, the thermal behavior of the rf-driven ion trap must be precisely known. This determination is even more difficult when scalable linear ion traps are used. Such traps enable a more advanced control of multiple ions and have become a platform for new applications in quantum metrology, simulation, and computation. Nevertheless, their complex structure makes it more difficult to precisely determine its temperature in operation and thus the related systematic uncertainty. We present here scalable linear ion traps for optical clocks, which exhibit very low temperature rise under operation. We use a finite-element model refined with experimental measurements to determine the thermal distribution in the ion trap and the temperature at the position of the ions. The trap temperature is investigated at different rf-drive frequencies and amplitudes with an infrared camera and integrated temperature sensors. We show that for typical trapping parameters for In+, Al+, Lu+, Ca+, Sr+, or Yb+ ions, the temperature rise at the position of the ions resulting from rf heating of the trap stays below 700 mK and can be controlled with an uncertainty on the order of a few 100 mK maximum. The corresponding uncertainty of the trap-related blackbody radiation shift is in the low 10−19 and even 10−20 regime for 171Yb+(E3) and 115In+, respectively.
Trapped ions are ideally suited for precision spectroscopy, as is evident from the remarkably low systematic uncertainties of single-ion clocks. The major weakness of these clocks is the long averaging time, necessitated by the low signal of a single atom. An increased number of ions can overcome this limitation and allow for the implementation of novel clock schemes. However, this presents the challenge to maintain the excellent control over systematic shifts of a single particle in spatially extended and strongly coupled many-body systems. We measure and deduce systematic frequency uncertainties related to spectroscopy with ion chains in an rf trap array designed for precision spectroscopy on simultaneously trapped ion ensembles. For the example of an In+{\mathrm{In}}^{+}In+ clock, sympathetically cooled with Yb+{\mathrm{Yb}}^{+}Yb+ ions, we show in our system that the expected systematic frequency uncertainties related to multi-ion operation can be below $1\ifmmode\times\else\texttimes\fi{}{10}^{\ensuremath{-}19}$. Our results pave the way to advanced spectroscopy schemes such as entangled clock spectroscopy and cascaded clock operation.
Optical clocks based on trapped ions can achieve systematic frequency uncertainties below 10${}^{\ensuremath{-}18}$, enabling relativistic geodesy and precise tests of fundamental physics. However, today's single-ion clocks require averaging times of over a week to resolve frequencies at this level, and no multi-ion clock has been implemented, due to difficulties in controlling ion motion. The authors present an ion-trap array that confines up to 100 clock ions with time-dilation shifts in the low-10${}^{\ensuremath{-}19}$ range, and measure the driven motion of individual ions within an ion crystal. These results point to the next generation of ion clocks, and the realization of clock schemes that have languished.