Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

IEEE Transactions on Instrumentation and Measurement

Precise Measurement of Magnetic Shielding Residual Field and Light Shift Based on 87Rb Atomic Magnetometer

Binbin Zhao, Junjian Tang, Lin Li, Ying Liu, Yueyang Zhai

Published Jan 1, 2023• 4 citations
Publisher

Abstract

Atomic magnetometers (AMs) are used in various fields, including magnetocardiography and magnetoencephalography. In AMs, accurately distinguishing and measuring the light-shift equivalent magnetic field generated by the pump beam from the remanent field within the central area of a magnetic shield has been a significant challenge. This paper presents a novel measurement method that addresses this issue using87Rb AMs. By exploiting the distinctive responses of the magnetometer to oscillating magnetic fields under different pump photon spin polarization vectors s and employing a fitting technique at the resonance peak, we determined both the residual field and light shift. Furthermore, we conducted comprehensive numerical simulations to analyze the light shift of the pump beam under various conditions, e.g., photon spin vectors, intensities, and frequency detuning. Additionally, experimental measurements were performed to investigate the pressure broadening effect on the D1 line of the cell. The proposed method allows precise measurement of remanent fields while eliminating the influence of light shift; thus, it is useful for high-precision atomic device measurements in diverse experimental settings.

DOI
10.1109/tim.2023.3304705

Related papers

Fast In-Situ Triaxial Remanent Magnetic Field Measurement for Single-Beam SERF Atomic Magnetometer Based on Trisection Algorithm

Tengyue Long, Bangcheng Han, Xinda Song +3 more

Abstract We demonstrate a method for quickly and automatically detecting all three components of a remanent magnetic field around a shielded spin-exchange relaxation-free (SERF) atomic magnetometer (AM) using the trisection algorithm (TSA) for zero-field resonance (ZFR). To satisfy the measurement of AMs, a resonance light of the 87 Rb D1 line with a spectral width of less than 1MHz is converted to circular polarization by a linear polarizer and a quarter-wave plate. After the light beam has passed through the alkali metal vapor cell, the residual magnetic field can be measured by searching for triaxial ZFR optical peaks. The TSA stably reduces the measurement time to 2.41 s on average and improves the measurement accuracy, significantly outpacing existing methods. The weighted averages of all measurements with corresponding uncertainties are (−15.437 ± 0.022)nT, (6.062 ± 0.021)nT, and (−14.158 ± 0.052)nT on the x -, y -, and z -axes, respectively. These improvements could facilitate more extremely weak magnetic studies in real time, such as magnetoencephalography (MEG) and magnetocardiography (MCG) measurements.

Photonic Sensors•Jan 1, 2022•28 citations

In-situ measurement of magnetic field gradient in a magnetic shield by a spin-exchange relaxation-free magnetometer

Jiancheng Fang, Tao Wang, Hong Zhang +2 more

A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which would lead to additional gradient broadening. It is impossible to use an ex-situ magnetometer to measure magnetic field gradient in the region of a cell, whose length of side is several centimeters. The method demonstrated in this paper can realize the in-situ measurement of the magnetic field gradient inside the cell, which is significant for the spin relaxation study. The magnetic field gradients along the longitudinal axis of the magnetic shield are measured by a spin-exchange relaxation-free (SERF) magnetometer by adding a magnetic field modulation in the probe beam’s direction. The transmissivity of the cell for the probe beam is always inhomogeneous along the pump beam direction, and the method proposed in this paper is independent of the intensity of the probe beam, which means that the method is independent of the cell’s transmissivity. This feature makes the method more practical experimentally. Moreover, the AC-Stark shift can seriously degrade and affect the precision of the magnetic field gradient measurement. The AC-Stark shift is suppressed by locking the pump beam to the resonance of potassium’s D1 line. Furthermore, the residual magnetic fields are measured with σ + - and σ – -polarized pump beams, which can further suppress the effect of the AC-Stark shift. The method of measuring in-situ magnetic field gradient has achieved a magnetic field gradient precision of better than 30 pT/mm.

Chinese Physics B•Jun 1, 2015•13 citations

In-situ measurement and cancellation of the light-shift in fiber-coupled atomic magnetometers

Binbin Zhao, Junjian Tang, Lin Li +4 more

In optical atomic magnetometers (AMs), the light-shift caused by the circularly polarized pumping beam have a significant impact on the response and is also one of the non-negligible sources of the noise. In this paper, we develop a novel method whereby utilizing the symmetry of the frequency response in an AM to measure and cancel the light-shift. Furthermore, we theoretically analyze and experimentally verify a rapid method of magnetic field compensation and the approach is convenient to measure and cancel of the light-shift. Moreover, the influence of intensity and frequency of the pumping beam is also investigated. The proposed method of in - situ measurement and cancellation of light-shift will be particularly profitable to other optical systems based on AMs.

Optics Express•Nov 8, 2022•7 citations

All-optical dual-axis zero-field atomic magnetometer using light-shift modulation

Xiaoyu Li, Bangcheng Han, Kaixuan Zhang +4 more

Functional imaging equipment based on miniaturized atomic magnetometers with array arrangement exhibits promising prospects in biomagnetic scenarios. However, crosstalk from the modulated magnetic field between adjacent sensors degrades the imaging accuracy. To address this issue, this study proposes an all-optical dual-axis zero-field atomic magnetometer using light-shift modulation. We utilize an acousto-optic modulator to modulate a detuned circularly polarized beam for pumping the atomic spin ensembles. This beam allows for the optical modulation of spin polarization and meanwhile generates a light-shift modulation, effectively replacing the conventional magnetic field modulation. By using a probe beam to detect the optical rotation angle perpendicular to the direction of the pump beam, we construct an all-optical configuration of a longitudinally modulated atomic magnetometer, enabling dual-axis magnetic field measurements. Experimental results demonstrate dual-axis sensitivities of 29 and 15fT/Hz1/2, respectively. This method eliminates the need for conventional coil-based magnetic field modulation, thereby paving the way for potential applications in magnetocardiography and magnetoencephalography.Received 3 August 2023Revised 13 November 2023Accepted 4 December 2023DOI:https://doi.org/10.1103/PhysRevApplied.21.014023© 2024 American Physical SocietyPhysics Subject Headings (PhySH)Research AreasMagneto-optical effectMagnetometryOptical pumpingStark effectPhysical SystemsAlkali metalsAtomic gasesTechniquesOptically detected magnetic resonancePrecision measurementsAtomic, Molecular & OpticalCondensed Matter, Materials & Applied Physics

Physical Review Applied•Jan 16, 2024•75 citations

The effect of tensor light shift on residual magnetic field compensation in a nuclear spin co-magnetometer

Yuchen Jia, Zhanchao Liu, Ming Ding +3 more

In a nuclear spin co-magnetometer, it was found that the probe light parameters have a significant impact on the transverse residual magnetic field compensation. In this paper, we demonstrated that this effect is caused by the tensor light shifts of the linearly polarized probe light. This effect can be suppressed at a certain probe light polarization. We obtained this probe light polarization experimentally and reduced the impact of probe power on magnetic field compensation by 35 times. The impact of probe light frequency is also suppressed. Furthermore, the influence of the pump power, the static magnetic field, and the cell temperature on this optimized polarization was investigated. The tensor light shift can be suppressed at about 17° polarization under different conditions in our system. Moreover, the actual residual magnetic field in the magnetic shields can be obtained, which is useful for the magnetic field design of the co-magnetometer, and this method can also be extended to other atomic devices to suppress the tensor light shift.

Applied Physics Letters•Apr 6, 2020•13 citations

Dual-Axis Measurement and Suppression Method for Light Shift Based on a Single-Beam Compact SERF Atomic Magnetometer

Kexuan Miao, Tao Hu, Yan Chang +2 more

The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.

IEEE Sensors Journal•Jan 7, 2025•3 citations
Atomic magnetometers (AMs) are used in various fields, including magnetocardiography and magnetoencephalography. In AMs, accurately distinguishing and measuring the light-shift equivalent magnetic field generated by the pump beam from the remanent field within the central area of a magnetic shield has been a significant challenge. This paper presents a novel measurement method that addresses this issue using87Rb AMs. By exploiting the distinctive responses of the magnetometer to oscillating magnetic fields under different pump photon spin polarization vectors s and employing a fitting technique at the resonance peak, we determined both the residual field and light shift. Furthermore, we conducted comprehensive numerical simulations to analyze the light shift of the pump beam under various conditions, e.g., photon spin vectors, intensities, and frequency detuning. Additionally, experimental measurements were performed to investigate the pressure broadening effect on the D1 line of the cell. The proposed method allows precise measurement of remanent fields while eliminating the influence of light shift; thus, it is useful for high-precision atomic device measurements in diverse experimental settings.
Abstract We demonstrate a method for quickly and automatically detecting all three components of a remanent magnetic field around a shielded spin-exchange relaxation-free (SERF) atomic magnetometer (AM) using the trisection algorithm (TSA) for zero-field resonance (ZFR). To satisfy the measurement of AMs, a resonance light of the 87 Rb D1 line with a spectral width of less than 1MHz is converted to circular polarization by a linear polarizer and a quarter-wave plate. After the light beam has passed through the alkali metal vapor cell, the residual magnetic field can be measured by searching for triaxial ZFR optical peaks. The TSA stably reduces the measurement time to 2.41 s on average and improves the measurement accuracy, significantly outpacing existing methods. The weighted averages of all measurements with corresponding uncertainties are (−15.437 ± 0.022)nT, (6.062 ± 0.021)nT, and (−14.158 ± 0.052)nT on the x -, y -, and z -axes, respectively. These improvements could facilitate more extremely weak magnetic studies in real time, such as magnetoencephalography (MEG) and magnetocardiography (MCG) measurements.
A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which would lead to additional gradient broadening. It is impossible to use an ex-situ magnetometer to measure magnetic field gradient in the region of a cell, whose length of side is several centimeters. The method demonstrated in this paper can realize the in-situ measurement of the magnetic field gradient inside the cell, which is significant for the spin relaxation study. The magnetic field gradients along the longitudinal axis of the magnetic shield are measured by a spin-exchange relaxation-free (SERF) magnetometer by adding a magnetic field modulation in the probe beam’s direction. The transmissivity of the cell for the probe beam is always inhomogeneous along the pump beam direction, and the method proposed in this paper is independent of the intensity of the probe beam, which means that the method is independent of the cell’s transmissivity. This feature makes the method more practical experimentally. Moreover, the AC-Stark shift can seriously degrade and affect the precision of the magnetic field gradient measurement. The AC-Stark shift is suppressed by locking the pump beam to the resonance of potassium’s D1 line. Furthermore, the residual magnetic fields are measured with σ + - and σ – -polarized pump beams, which can further suppress the effect of the AC-Stark shift. The method of measuring in-situ magnetic field gradient has achieved a magnetic field gradient precision of better than 30 pT/mm.
In optical atomic magnetometers (AMs), the light-shift caused by the circularly polarized pumping beam have a significant impact on the response and is also one of the non-negligible sources of the noise. In this paper, we develop a novel method whereby utilizing the symmetry of the frequency response in an AM to measure and cancel the light-shift. Furthermore, we theoretically analyze and experimentally verify a rapid method of magnetic field compensation and the approach is convenient to measure and cancel of the light-shift. Moreover, the influence of intensity and frequency of the pumping beam is also investigated. The proposed method of in - situ measurement and cancellation of light-shift will be particularly profitable to other optical systems based on AMs.
Functional imaging equipment based on miniaturized atomic magnetometers with array arrangement exhibits promising prospects in biomagnetic scenarios. However, crosstalk from the modulated magnetic field between adjacent sensors degrades the imaging accuracy. To address this issue, this study proposes an all-optical dual-axis zero-field atomic magnetometer using light-shift modulation. We utilize an acousto-optic modulator to modulate a detuned circularly polarized beam for pumping the atomic spin ensembles. This beam allows for the optical modulation of spin polarization and meanwhile generates a light-shift modulation, effectively replacing the conventional magnetic field modulation. By using a probe beam to detect the optical rotation angle perpendicular to the direction of the pump beam, we construct an all-optical configuration of a longitudinally modulated atomic magnetometer, enabling dual-axis magnetic field measurements. Experimental results demonstrate dual-axis sensitivities of 29 and 15fT/Hz1/2, respectively. This method eliminates the need for conventional coil-based magnetic field modulation, thereby paving the way for potential applications in magnetocardiography and magnetoencephalography.Received 3 August 2023Revised 13 November 2023Accepted 4 December 2023DOI:https://doi.org/10.1103/PhysRevApplied.21.014023© 2024 American Physical SocietyPhysics Subject Headings (PhySH)Research AreasMagneto-optical effectMagnetometryOptical pumpingStark effectPhysical SystemsAlkali metalsAtomic gasesTechniquesOptically detected magnetic resonancePrecision measurementsAtomic, Molecular & OpticalCondensed Matter, Materials & Applied Physics
In a nuclear spin co-magnetometer, it was found that the probe light parameters have a significant impact on the transverse residual magnetic field compensation. In this paper, we demonstrated that this effect is caused by the tensor light shifts of the linearly polarized probe light. This effect can be suppressed at a certain probe light polarization. We obtained this probe light polarization experimentally and reduced the impact of probe power on magnetic field compensation by 35 times. The impact of probe light frequency is also suppressed. Furthermore, the influence of the pump power, the static magnetic field, and the cell temperature on this optimized polarization was investigated. The tensor light shift can be suppressed at about 17° polarization under different conditions in our system. Moreover, the actual residual magnetic field in the magnetic shields can be obtained, which is useful for the magnetic field design of the co-magnetometer, and this method can also be extended to other atomic devices to suppress the tensor light shift.
The light shift in a spin-exchange relaxation-free (SERF) atomic magnetometer (AM) generated by detuning of circularly polarized pump light, results in deviations of orthogonality measurement and attenuation of magnetometer response. In this paper, we propose and systematically investigate a dual-axis method to suppress light shift based on a self-developed single-beam compact SERF AM capable of measuring magnetic field components along two orthogonal sensitive axes. By sequentially observing the non-sensitive axis response and applying a magnetic field along the pump light direction, the virtual magnetic field induced by light shift is compensated and is rigorously demonstrated as a dominant component in this direction. Experimental results show a significant reduction in crosstalk between the dual sensitive axes, improving accuracy in resonant frequency determination of87Rb atoms and orthogonality evaluation of triaxial coils. Furthermore, the performance of dual-axis measurement in the SERF AM is tested, showing a more notable enhancement than that of single-axis measurement.