Applied Physics Letters

The effect of tensor light shift on residual magnetic field compensation in a nuclear spin co-magnetometer

Yuchen Jia, Zhanchao Liu, Ming Ding, Zhen Chai, Xiaoyang Liang, Wenfeng Wu

Published Apr 6, 2020• 13 citations
Publisher

Abstract

In a nuclear spin co-magnetometer, it was found that the probe light parameters have a significant impact on the transverse residual magnetic field compensation. In this paper, we demonstrated that this effect is caused by the tensor light shifts of the linearly polarized probe light. This effect can be suppressed at a certain probe light polarization. We obtained this probe light polarization experimentally and reduced the impact of probe power on magnetic field compensation by 35 times. The impact of probe light frequency is also suppressed. Furthermore, the influence of the pump power, the static magnetic field, and the cell temperature on this optimized polarization was investigated. The tensor light shift can be suppressed at about 17° polarization under different conditions in our system. Moreover, the actual residual magnetic field in the magnetic shields can be obtained, which is useful for the magnetic field design of the co-magnetometer, and this method can also be extended to other atomic devices to suppress the tensor light shift.

DOI
10.1063/1.5142315

Related papers

Transverse light-shift in a spin-exchange relaxation-free co-magnetometer: measurement, decoupling, and suppression

Sixun Liu, Ruigang Wang, Linlin Yuan +6 more

The transverse light-shift can induce non-negligible polarization error in the output signal of spin-exchange relaxation-free (SERF) co-magnetometer. In this paper, a novel method for rapid measurement of transverse light-shift based on the error of steady-state response of co-magnetometer is proposed firstly, then the sources of transverse light-shift in a compact SERF co-magnetometer is modeled and analyzed from three aspects: the non-ideal linear polarization of probe laser, the circular dichroism of the atomic spin ensembles, and the stress-induced birefringence effect of the cell wall. Furthermore, the decoupling and suppression methods of transverse light-shift based on a degree of circular polarization (DOCP) regulation scheme is presented, to realize the decoupling measurement of the transverse light-shift introduced by the whole co-magnetometer cell, and cancel it out with the non-ideal linear polarization of the probe laser. Eventually, the DOCP regulation scheme suggested in this paper achieves more than a 67% suppression ratio in transverse light-shift, and the short- and long-term performance of SERF co-magnetometer are improved due to the reduction of the coupling effect between the probe laser power and transverse field. Moreover, the measurement, decoupling and suppression methods provided in this paper also have the potential to be applied to other atomic sensors, such as the SERF magnetometers and nuclear spin co-magnetometers.

Optics Express•Apr 8, 2022•33 citations

Precise Measurement of Magnetic Shielding Residual Field and Light Shift Based on 87Rb Atomic Magnetometer

Binbin Zhao, Junjian Tang, Lin Li +2 more

Atomic magnetometers (AMs) are used in various fields, including magnetocardiography and magnetoencephalography. In AMs, accurately distinguishing and measuring the light-shift equivalent magnetic field generated by the pump beam from the remanent field within the central area of a magnetic shield has been a significant challenge. This paper presents a novel measurement method that addresses this issue using87Rb AMs. By exploiting the distinctive responses of the magnetometer to oscillating magnetic fields under different pump photon spin polarization vectors s and employing a fitting technique at the resonance peak, we determined both the residual field and light shift. Furthermore, we conducted comprehensive numerical simulations to analyze the light shift of the pump beam under various conditions, e.g., photon spin vectors, intensities, and frequency detuning. Additionally, experimental measurements were performed to investigate the pressure broadening effect on the D1 line of the cell. The proposed method allows precise measurement of remanent fields while eliminating the influence of light shift; thus, it is useful for high-precision atomic device measurements in diverse experimental settings.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2023•4 citations

Nuclear Zeeman Effect on Heading Errors and the Suppression in Atomic Magnetometers

Chang, Yue, Guo, Yu-Hao, Shuang-Ai Wan +1 more

The heading error has been known to be caused mainly by the nonlinear Zeeman effect and the orientation-dependent light shift. In this work, we find that the nuclear Zeeman effect can also have a significant impact on the heading errors, especially for continuously-driving magnetometers with unresolved magnetic transitions. It not only shifts the precession frequency but deforms the heading errors and causes asymmetry: the heading errors for pump lasers with opposite helicities are different. The heading error also depends on the relative direction (parallel or vertical) of the probe laser to the RF driving magnetic field. Thus, one can design the configuration of the magnetometer and make it work in the smaller-heading-error regime. To suppress the heading error, our studies suggest to sum up the output precession frequencies from atomic cells pumped by two lasers with opposite helicities and probed by lasers propagating in orthogonal directions (one parallel and another perpendicular to the RF field), instead of utilizing probe lasers propagating in the same directions. Due to the nuclear Zeeman effect, the average precession frequencies in the latter case can have a non-negligible angular dependence, while in the former case the nuclear-Zeeman-effect induced heading error can be largely compensated and the residue is within 1Hz. Furthermore, for practical use, we propose to simply utilize a small magnetic field parallel/antiparallel to the pump laser. By tuning the magnitude of this auxiliary field, the heading error can be flattened around different angles, which can improve the accuracy when the magnetometer works around a certain orientation angle.

arXiv:2102.03037•Jan 1, 2021•2 citations

In situ magnetic compensation for potassium spin-exchange relaxation-free magnetometer considering probe beam pumping effect

Jiancheng Fang, Tao Wang, Wei Quan +4 more

A novel method to compensate the residual magnetic field for an atomic magnetometer consisting of two perpendicular beams of polarizations was demonstrated in this paper. The method can realize magnetic compensation in the case where the pumping rate of the probe beam cannot be ignored. In the experiment, the probe beam is always linearly polarized, whereas, the probe beam contains a residual circular component due to the imperfection of the polarizer, which leads to the pumping effect of the probe beam. A simulation of the probe beam's optical rotation and pumping rate was demonstrated. At the optimized points, the wavelength of the probe beam was optimized to achieve the largest optical rotation. Although, there is a small circular component in the linearly polarized probe beam, the pumping rate of the probe beam was non-negligible at the optimized wavelength which if ignored would lead to inaccuracies in the magnetic field compensation. Therefore, the dynamic equation of spin evolution was solved by considering the pumping effect of the probe beam. Based on the quasi-static solution, a novel magnetic compensation method was proposed, which contains two main steps: (1) the non-pumping compensation and (2) the sequence compensation with a very specific sequence. After these two main steps, a three-axis in situ magnetic compensation was achieved. The compensation method was suitable to design closed-loop spin-exchange relaxation-free magnetometer. By a combination of the magnetic compensation and the optimization, the magnetic field sensitivity was approximately 4 fT/Hz(1/2), which was mainly dominated by the noise of the magnetic shield.

Review of Scientific Instruments•Jun 1, 2014•69 citations

Low frequency magnetic field suppression in an atomic spin co-magnetometer with a large electron magnetic field

Jiancheng Fang, Yao Chen, Sheng Zou +5 more

Abstract In a K-Rb- 21 Ne co-magnetometer, the Rb electron magnetic field which is experienced by the nuclear spin is about 100 times larger than that of the K in a K- 3 He co-magnetometer. The large electron magnetic field which is neglected in the K- 3 He co-magnetometer coupled Bloch equations model is considered here in the K-Rb- 21 Ne co-magnetometer to study the low frequency magnetic field suppression effect. Theoretical analysis and experimental results shows that in the K-Rb- 21 Ne spin co-magnetometer, not only the nuclear spin but also the large electron spin magnetic field compensate the external magnetic field noise. By comparison, only the 3 He nuclear spins mainly compensate the external magnetic field noise in a K- 3 He co-magnetometer. With this study, in addition to just increasing the magnetic field of the nuclear spins, we can suppress the magnetic field noise by increasing the density of the electron spin. We also studied how the magnetic field suppression effect relates to the scale factor of the K-Rb- 21 Ne co-magnetometer and we compared the scale factor with that of the K- 3 He co-magnetometer. Lastly, we show the sensitivity of our co-magnetometer. The magnetic field noise, the air density fluctuation noise and pumping power optimization are studied to improve the sensitivity of the co-magnetometer.

Journal of Physics B Atomic Molecular and Optical Physics•Mar 7, 2016•49 citations

Measurement Sensitivity Improvement of All-Optical Atomic Spin Magnetometer by Suppressing Noises

Xiyuan Chen, Hong Zhang, Sheng Zou

Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz(1/2) was successfully achieved by suppressing noises and optimizing parameters.

Sensors•Jun 17, 2016•9 citations
In a nuclear spin co-magnetometer, it was found that the probe light parameters have a significant impact on the transverse residual magnetic field compensation. In this paper, we demonstrated that this effect is caused by the tensor light shifts of the linearly polarized probe light. This effect can be suppressed at a certain probe light polarization. We obtained this probe light polarization experimentally and reduced the impact of probe power on magnetic field compensation by 35 times. The impact of probe light frequency is also suppressed. Furthermore, the influence of the pump power, the static magnetic field, and the cell temperature on this optimized polarization was investigated. The tensor light shift can be suppressed at about 17° polarization under different conditions in our system. Moreover, the actual residual magnetic field in the magnetic shields can be obtained, which is useful for the magnetic field design of the co-magnetometer, and this method can also be extended to other atomic devices to suppress the tensor light shift.
The transverse light-shift can induce non-negligible polarization error in the output signal of spin-exchange relaxation-free (SERF) co-magnetometer. In this paper, a novel method for rapid measurement of transverse light-shift based on the error of steady-state response of co-magnetometer is proposed firstly, then the sources of transverse light-shift in a compact SERF co-magnetometer is modeled and analyzed from three aspects: the non-ideal linear polarization of probe laser, the circular dichroism of the atomic spin ensembles, and the stress-induced birefringence effect of the cell wall. Furthermore, the decoupling and suppression methods of transverse light-shift based on a degree of circular polarization (DOCP) regulation scheme is presented, to realize the decoupling measurement of the transverse light-shift introduced by the whole co-magnetometer cell, and cancel it out with the non-ideal linear polarization of the probe laser. Eventually, the DOCP regulation scheme suggested in this paper achieves more than a 67% suppression ratio in transverse light-shift, and the short- and long-term performance of SERF co-magnetometer are improved due to the reduction of the coupling effect between the probe laser power and transverse field. Moreover, the measurement, decoupling and suppression methods provided in this paper also have the potential to be applied to other atomic sensors, such as the SERF magnetometers and nuclear spin co-magnetometers.
Atomic magnetometers (AMs) are used in various fields, including magnetocardiography and magnetoencephalography. In AMs, accurately distinguishing and measuring the light-shift equivalent magnetic field generated by the pump beam from the remanent field within the central area of a magnetic shield has been a significant challenge. This paper presents a novel measurement method that addresses this issue using87Rb AMs. By exploiting the distinctive responses of the magnetometer to oscillating magnetic fields under different pump photon spin polarization vectors s and employing a fitting technique at the resonance peak, we determined both the residual field and light shift. Furthermore, we conducted comprehensive numerical simulations to analyze the light shift of the pump beam under various conditions, e.g., photon spin vectors, intensities, and frequency detuning. Additionally, experimental measurements were performed to investigate the pressure broadening effect on the D1 line of the cell. The proposed method allows precise measurement of remanent fields while eliminating the influence of light shift; thus, it is useful for high-precision atomic device measurements in diverse experimental settings.
The heading error has been known to be caused mainly by the nonlinear Zeeman effect and the orientation-dependent light shift. In this work, we find that the nuclear Zeeman effect can also have a significant impact on the heading errors, especially for continuously-driving magnetometers with unresolved magnetic transitions. It not only shifts the precession frequency but deforms the heading errors and causes asymmetry: the heading errors for pump lasers with opposite helicities are different. The heading error also depends on the relative direction (parallel or vertical) of the probe laser to the RF driving magnetic field. Thus, one can design the configuration of the magnetometer and make it work in the smaller-heading-error regime. To suppress the heading error, our studies suggest to sum up the output precession frequencies from atomic cells pumped by two lasers with opposite helicities and probed by lasers propagating in orthogonal directions (one parallel and another perpendicular to the RF field), instead of utilizing probe lasers propagating in the same directions. Due to the nuclear Zeeman effect, the average precession frequencies in the latter case can have a non-negligible angular dependence, while in the former case the nuclear-Zeeman-effect induced heading error can be largely compensated and the residue is within 1Hz. Furthermore, for practical use, we propose to simply utilize a small magnetic field parallel/antiparallel to the pump laser. By tuning the magnitude of this auxiliary field, the heading error can be flattened around different angles, which can improve the accuracy when the magnetometer works around a certain orientation angle.
A novel method to compensate the residual magnetic field for an atomic magnetometer consisting of two perpendicular beams of polarizations was demonstrated in this paper. The method can realize magnetic compensation in the case where the pumping rate of the probe beam cannot be ignored. In the experiment, the probe beam is always linearly polarized, whereas, the probe beam contains a residual circular component due to the imperfection of the polarizer, which leads to the pumping effect of the probe beam. A simulation of the probe beam's optical rotation and pumping rate was demonstrated. At the optimized points, the wavelength of the probe beam was optimized to achieve the largest optical rotation. Although, there is a small circular component in the linearly polarized probe beam, the pumping rate of the probe beam was non-negligible at the optimized wavelength which if ignored would lead to inaccuracies in the magnetic field compensation. Therefore, the dynamic equation of spin evolution was solved by considering the pumping effect of the probe beam. Based on the quasi-static solution, a novel magnetic compensation method was proposed, which contains two main steps: (1) the non-pumping compensation and (2) the sequence compensation with a very specific sequence. After these two main steps, a three-axis in situ magnetic compensation was achieved. The compensation method was suitable to design closed-loop spin-exchange relaxation-free magnetometer. By a combination of the magnetic compensation and the optimization, the magnetic field sensitivity was approximately 4 fT/Hz(1/2), which was mainly dominated by the noise of the magnetic shield.
Abstract In a K-Rb- 21 Ne co-magnetometer, the Rb electron magnetic field which is experienced by the nuclear spin is about 100 times larger than that of the K in a K- 3 He co-magnetometer. The large electron magnetic field which is neglected in the K- 3 He co-magnetometer coupled Bloch equations model is considered here in the K-Rb- 21 Ne co-magnetometer to study the low frequency magnetic field suppression effect. Theoretical analysis and experimental results shows that in the K-Rb- 21 Ne spin co-magnetometer, not only the nuclear spin but also the large electron spin magnetic field compensate the external magnetic field noise. By comparison, only the 3 He nuclear spins mainly compensate the external magnetic field noise in a K- 3 He co-magnetometer. With this study, in addition to just increasing the magnetic field of the nuclear spins, we can suppress the magnetic field noise by increasing the density of the electron spin. We also studied how the magnetic field suppression effect relates to the scale factor of the K-Rb- 21 Ne co-magnetometer and we compared the scale factor with that of the K- 3 He co-magnetometer. Lastly, we show the sensitivity of our co-magnetometer. The magnetic field noise, the air density fluctuation noise and pumping power optimization are studied to improve the sensitivity of the co-magnetometer.
Quantum manipulation technology and photoelectric detection technology have jointly facilitated the rapid development of ultra-sensitive atomic spin magnetometers. To improve the output signal and sensitivity of the spin-exchange-relaxation-free (SERF) atomic spin magnetometer, the noises influencing on the output signal and the sensitivity were analyzed, and the corresponding noise suppression methods were presented. The magnetic field noises, including the residual magnetic field noise and the light shift noise, were reduced to approximately zero by employing the magnetic field compensation method and by adjusting the frequency of the pump beam, respectively. With respect to the operation temperature, the simulation results showed that the temperature of the potassium atomic spin magnetometer realizing the spin-exchange relaxation-free regime was 180 °C. Moreover, the fluctuation noises of the frequency and the power were suppressed by using the frequency and the power stable systems. The experimental power stability results showed that the light intensity stability was enhanced 10%. Contrast experiments on the sensitivity were carried out to demonstrate the validity of the suppression methods. Finally, a sensitivity of 13 fT/Hz(1/2) was successfully achieved by suppressing noises and optimizing parameters.