Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Atoms

Dynamic Response of a Light-Modulated Magnetometer to Time-Dependent Fields

G. Bevilacqua, V. Biancalana, Yordanka V. Dancheva

Published Aug 11, 2023• 2 citations
Publisher

Abstract

The dynamic response of a Bell-and-Bloom magnetometer to a parallel (to the bias field) time-dependent field is studied by means of a model that goes beyond the commonly assumed quasi-static regime. The findings unveil features that are related to the parametric nature of the considered system. It is shown that for low-amplitude time-dependent fields, different operating conditions are possible and that, besides the commonly reported low-pass filter behavior, a band-pass response emerges. Moreover, we show that a larger amplitude of the time-dependent field makes the parametric nature of the system appear more clearly in the output signal. A harmonic analysis of the latter is numerically performed to highlight and characterize these emerging features.

DOI
10.3390/atoms11080111

Related papers

Derivation of bandwidth and filter characteristics of various types of optically pumped magnetometers

Thomas Schönau, Theo Scholtes, Ronny Stolz

We present a unified and easy-to-follow analytical framework based on the Bloch equations for deriving the small-signal frequency response of several common types of optically pumped magnetometers (OPMs). These include the Mx, light-shift dispersed Mz, Bell–Bloom, and RF (radio-frequency) types, as well as the class of unmodulated zero-field OPMs. It is shown that, depending on the operating regime, the frequency response of some of these magnetometers deviates significantly from the commonly assumed first-order filter behavior.

Journal of Applied Physics•Mar 3, 2026•0 citations

Comprehensive influence of modulated and bias magnetic fields on an atomic magnetometer

Yan Yin, Binquan Zhou, Kaifeng Yin +4 more

Abstract The comprehensive influence of the amplitude and frequency of the modulated magnetic field and the magnitude of the bias magnetic field on the performance of an atomic magnetometer have been investigated. Under different magnetic fields, the combined action of the spin precession signal caused by a high-amplitude magnetic field and the influence of magnetic field on relaxation makes the time domain output signal and the amplitude of the first to fourth harmonics show different characteristics, which cannot be explained by the classical analytical calculation solution. By considering the influence of the magnetic field on the transverse relaxation, a more complete model is constructed to explain the phenomenon with a numerical solution, and the overall fit is 93.26%. Based on the single beam and magnetic field modulation scheme, a compact magnetometer is constructed for verification, with a volume of 56.7 cm 3 and a sensitivity of 30 fT/Hz 1/2 .

Measurement Science and Technology•Jan 14, 2021•8 citations

Study of the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers

Meiling Wang, Meng-Bing Wang, Guiying Zhang +1 more

We theoretically and experimentally study the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers. The theoretical and the experimental results are in good agreement for duty cycles and corresponding pumping rates ranging over 2 orders of magnitude. Our study gives the maximum field response as a function of duty cycle and pumping rate. Especially, for a fixed duty cycle, the maximum field response is obtained when the time averaged pumping rate, which is the product of pumping rate and duty cycle, is equal to the transverse relaxation rate in the dark. By using a combination of small duty cycle and large pumping rate, one can increase the maximum field response by up to a factor of 2 or π /2, relative to that of the sinusoidal modulation or the 50% duty cycle square-wave modulation respectively. We further show that the same pumping condition is also practically optimal for the sensitivity due to the fact that the signal at resonance is insensitive to the fluctuations of pumping rate and duty cycle.

Chinese Physics B•Jun 1, 2016•11 citations

Close-Loop Bell–Bloom Magnetometer with Amplitude Modulation

Haichao Huang, Haifeng Dong, Hui-Jie Hao +1 more

A high sensitive optical amplitude modulation magnetometer is investigated and demonstrated experimentally. We build an experimental platform for the atomic magnetometer and configure it as a Bell–Bloom magnetometer with amplitude modulation of 50% duty cycle square waveform. The open-loop input-output model is deduced from the Bloch equation and is verified experimentally. Instead of locking the frequency by using a voltage control oscillator, we realize a closed loop using the coils to generate a feedback field which avoids the stringent requirement of a high resolution frequency meter and markedly expands the dynamic range as well as the bandwidth. We realize an open loop sensitivity of 0.8 pT/Hz 1/2 at 20 Hz using a single light beam, which exceeds that of the state-of-the-art Bell–Bloom magnetometers, and the corresponding closed loop sensitivity is 1.2 pT/Hz 1/2 .

Chinese Physics Letters•Sep 1, 2015•13 citations

Highly responsive ac scalar atomic magnetometer with long relaxation time

Akira Terao, K. Ban, S. Ichihara +2 more

We propose an operating condition for an optically pumped scalar atomic magnetometer with a unique band-pass frequency response. Under this operating condition, the signal response of the magnetometer is increased threefold around a nonzero resonance frequency. The resonance frequency is equal to the detuning between the Larmor frequency and the frequency of the oscillating magnetic field used for excitation. The resonance is explained in terms of the characteristics of the first-order perturbation expansion of the Bloch equation for a modulated bias magnetic field. The scalar magnetometer provides an enhanced magnetic response around its resonance frequency even beyond the cutoff frequency, which is defined as the inverse of the phase relaxation time of the spin polarization.

Physical Review A•Dec 23, 2013•15 citations

Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer

Fei Lu, Shuying Wang, Nuozhou Xu +3 more

Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.

Photonics•Oct 25, 2022•7 citations
The dynamic response of a Bell-and-Bloom magnetometer to a parallel (to the bias field) time-dependent field is studied by means of a model that goes beyond the commonly assumed quasi-static regime. The findings unveil features that are related to the parametric nature of the considered system. It is shown that for low-amplitude time-dependent fields, different operating conditions are possible and that, besides the commonly reported low-pass filter behavior, a band-pass response emerges. Moreover, we show that a larger amplitude of the time-dependent field makes the parametric nature of the system appear more clearly in the output signal. A harmonic analysis of the latter is numerically performed to highlight and characterize these emerging features.
We present a unified and easy-to-follow analytical framework based on the Bloch equations for deriving the small-signal frequency response of several common types of optically pumped magnetometers (OPMs). These include the Mx, light-shift dispersed Mz, Bell–Bloom, and RF (radio-frequency) types, as well as the class of unmodulated zero-field OPMs. It is shown that, depending on the operating regime, the frequency response of some of these magnetometers deviates significantly from the commonly assumed first-order filter behavior.
Abstract The comprehensive influence of the amplitude and frequency of the modulated magnetic field and the magnitude of the bias magnetic field on the performance of an atomic magnetometer have been investigated. Under different magnetic fields, the combined action of the spin precession signal caused by a high-amplitude magnetic field and the influence of magnetic field on relaxation makes the time domain output signal and the amplitude of the first to fourth harmonics show different characteristics, which cannot be explained by the classical analytical calculation solution. By considering the influence of the magnetic field on the transverse relaxation, a more complete model is constructed to explain the phenomenon with a numerical solution, and the overall fit is 93.26%. Based on the single beam and magnetic field modulation scheme, a compact magnetometer is constructed for verification, with a volume of 56.7 cm 3 and a sensitivity of 30 fT/Hz 1/2 .
We theoretically and experimentally study the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers. The theoretical and the experimental results are in good agreement for duty cycles and corresponding pumping rates ranging over 2 orders of magnitude. Our study gives the maximum field response as a function of duty cycle and pumping rate. Especially, for a fixed duty cycle, the maximum field response is obtained when the time averaged pumping rate, which is the product of pumping rate and duty cycle, is equal to the transverse relaxation rate in the dark. By using a combination of small duty cycle and large pumping rate, one can increase the maximum field response by up to a factor of 2 or π /2, relative to that of the sinusoidal modulation or the 50% duty cycle square-wave modulation respectively. We further show that the same pumping condition is also practically optimal for the sensitivity due to the fact that the signal at resonance is insensitive to the fluctuations of pumping rate and duty cycle.
A high sensitive optical amplitude modulation magnetometer is investigated and demonstrated experimentally. We build an experimental platform for the atomic magnetometer and configure it as a Bell–Bloom magnetometer with amplitude modulation of 50% duty cycle square waveform. The open-loop input-output model is deduced from the Bloch equation and is verified experimentally. Instead of locking the frequency by using a voltage control oscillator, we realize a closed loop using the coils to generate a feedback field which avoids the stringent requirement of a high resolution frequency meter and markedly expands the dynamic range as well as the bandwidth. We realize an open loop sensitivity of 0.8 pT/Hz 1/2 at 20 Hz using a single light beam, which exceeds that of the state-of-the-art Bell–Bloom magnetometers, and the corresponding closed loop sensitivity is 1.2 pT/Hz 1/2 .
We propose an operating condition for an optically pumped scalar atomic magnetometer with a unique band-pass frequency response. Under this operating condition, the signal response of the magnetometer is increased threefold around a nonzero resonance frequency. The resonance frequency is equal to the detuning between the Larmor frequency and the frequency of the oscillating magnetic field used for excitation. The resonance is explained in terms of the characteristics of the first-order perturbation expansion of the Bloch equation for a modulated bias magnetic field. The scalar magnetometer provides an enhanced magnetic response around its resonance frequency even beyond the cutoff frequency, which is defined as the inverse of the phase relaxation time of the spin polarization.
Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.