Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Measurement Science and Technology

Comprehensive influence of modulated and bias magnetic fields on an atomic magnetometer

Yan Yin, Binquan Zhou, Kaifeng Yin, Junjian Tang, Xiaolin Ning, Bangcheng Han, Jiancheng Fang

Published Jan 14, 2021• 8 citations
Publisher

Abstract

Abstract The comprehensive influence of the amplitude and frequency of the modulated magnetic field and the magnitude of the bias magnetic field on the performance of an atomic magnetometer have been investigated. Under different magnetic fields, the combined action of the spin precession signal caused by a high-amplitude magnetic field and the influence of magnetic field on relaxation makes the time domain output signal and the amplitude of the first to fourth harmonics show different characteristics, which cannot be explained by the classical analytical calculation solution. By considering the influence of the magnetic field on the transverse relaxation, a more complete model is constructed to explain the phenomenon with a numerical solution, and the overall fit is 93.26%. Based on the single beam and magnetic field modulation scheme, a compact magnetometer is constructed for verification, with a volume of 56.7 cm 3 and a sensitivity of 30 fT/Hz 1/2 .

DOI
10.1088/1361-6501/abdb79

Related papers

The influence of modulated magnetic field on light absorption in SERF atomic magnetometer

Yan Yin, Binquan Zhou, Yaxiang Wang +4 more

A single-beam spin-exchange relaxation-free atomic magnetometer is ultra-sensitive in the zero field, which has great potential for the detection of a magnetoencephalogram. The addition of a modulated magnetic field is an important approach to achieve high sensitivity for devices of this kind. In this study, we discovered that the amplitude and frequency of the modulated magnetic field (modulation index 0–3) both influence the light absorption. We defined this effect into a function by combining theoretical analysis and the results of experiments. It is discovered that the transmission intensity decreases with an increase in the modulation index. This effect is weakened under the application of a high modulation index. In addition, the transmission intensity and bias magnetic field no longer follow a strict Lorentz curve, while a high degree of fit can be achieved by applying the numerical solution of the Bloch function. A compact magnetometer with a volume of 10 cm3 and a sensitivity of 20 fT/Hz is developed based on the single beam scheme for the proof of concept. Our study is crucial in two aspects: (1) Obtaining high sensitivity through a short measurement period and (2) alignment of the scale factor of the individual magnetometer in a detection array, which further pave the way for improvement in a magnetometer’s performance under a variety of optics platforms.

Review of Scientific Instruments•Jan 1, 2022•5 citations

The influence of temperature and modulated magnetic field on the transmission intensity of atomic magnetometer

Yan Yin, Binquan Zhou, Kaifeng Yin +5 more

Abstract The single-beam miniaturized atomic magnetometer with modulated magnetic field is one of the most capable approaches to biomagnetic measurements. The transmission intensity of the pumping beam is critical to the sensitivity of the magnetometer, which is affected by the density of alkali metal and the polarization of atomic spin. In this study, we investigated into the influence of three variables: the temperature of atomic vapour; the amplitude of the modulated magnetic field; the frequency of modulated magnetic field on the transmission intensity of pumping beam. We have defined their relationship into a function, and the calculated values through theoretical analysis have a high degree of fit with the measured values of numerous experiments. It is discovered that the transmission intensity decreases with the increase in temperature, and this effect is modified by the modulation index. A compact magnetometer is developed as a proof of concept based on single-beam scheme. The volume of this magnetometer is 10 cm 3 , and its dual axis sensitivity are both 30 fT/Hz 1 / 2 . Based on this relationship we find that two major improvements are achieved by separating the DC and AC components of transmission intensity: 1. Realizing closed-loop temperature control for atomic vapour which improved the stability of the magnetometer. 2. Achieving closed-loop dual axis magnetic measurements under a single-beam scheme, which extends the magnetometer’s scope of application.

Journal of Physics D Applied Physics•Aug 2, 2021•18 citations

Comprehensive analysis of the influence of magnetic field gradients on single-beam SERF atomic magnetometer

Jiajie Li, Ying Liu, Renjie Li +3 more

Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.

Results in Physics•Nov 30, 2023•11 citations

Bandwidth Expansion Through Large-Amplitude Modulation and Proportional Feedback for Single-Beam Atomic Magnetometers

Kun Wang, Jixi Lu, Yeguang Yan +7 more

Atomic magnetometers are widely acknowledged as one of the most sensitive devices for magnetic field measurement. Our study presents a novel method that enables bandwidth expansion of single-beam magnetometers in the spin-exchange relaxation-free regime. This method bases on increasing the modulation amplitude of magnetic field combining with negative feedback with proportional gain. Through our method, the magnetometer’s total relaxation rate is moderately increased by elevating modulation amplitude and frequency, and correspondingly, the detection bandwidth experiences dramatic improvement from 230 Hz to 1380 Hz. The application of negative feedback with proportional gain further increases this bandwidth to higher than 4 kHz, which is over 17 times of its original value. The sensitivity of the magnetometer under this condition is measured as 25 fT/$\text {Hz}^{\text {1/2}}$for open-loop scheme and 35 fT/$\text {Hz}^{\text {1/2}}$for closed-loop scheme. Comparatively, the sensitivity measured on conventional conditions in our experiment is 12 fT/$\text {Hz}^{\text {1/2}}$. This approach offers a profitable trade-off that extraordinary expansion of detection bandwidth can be acquired with the price of a little sensitivity loss. Our method is advantageous for miniaturization of atomic magnetometers as no extra hardware is added, which is of special interest for applications including biomagnetic measurement where large detection bandwidth is sometimes in need.

IEEE Sensors Journal•Dec 16, 2021•18 citations

DC-Bias-Magnetic-Field Dependence of Step Response in an Elliptically Polarized Single-Beam Atomic Magnetometer

Yuya Shoji, Khanuengchat Saenyot, Shunya Takahashi +1 more

A single-beam atomic magnetometer with elliptical polarization is simple in construction because it requires only one laser for both pumping and probing. When a small-signal magnetic field is input into the magnetometer after the DC magnetic field is set to zero, a full-wave cleared waveform is output. This characteristic is appropriate for calibration and measurement of DC magnetic fields, because the bias of such fields affects their sensitivity. In this paper, we examined the step-response waveform when a pulsed magnetic field with various DC magnetic-field biases was applied. The response waveform was measured in the time domain with an oscilloscope. The oscillation frequency did not depend on the step-magnetic-field difference but on the amplitude when changing from an absolute-zero magnetic field to a finite magnetic field. Because the DC magnetic field can be determined by measuring the frequency, the bias magnetic field of the atomic magnetometer can be adjusted to maintain the optimal point of operation.

International Electrical Engineering Congress (iEECON)•Mar 1, 2020•1 citation

Analysis and Suppression of the Cross-Axis Coupling Effect for Dual-Beam SERF Atomic Magnetometer

Fei Lu, Shuying Wang, Nuozhou Xu +3 more

Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.

Photonics•Oct 25, 2022•7 citations
Abstract The comprehensive influence of the amplitude and frequency of the modulated magnetic field and the magnitude of the bias magnetic field on the performance of an atomic magnetometer have been investigated. Under different magnetic fields, the combined action of the spin precession signal caused by a high-amplitude magnetic field and the influence of magnetic field on relaxation makes the time domain output signal and the amplitude of the first to fourth harmonics show different characteristics, which cannot be explained by the classical analytical calculation solution. By considering the influence of the magnetic field on the transverse relaxation, a more complete model is constructed to explain the phenomenon with a numerical solution, and the overall fit is 93.26%. Based on the single beam and magnetic field modulation scheme, a compact magnetometer is constructed for verification, with a volume of 56.7 cm 3 and a sensitivity of 30 fT/Hz 1/2 .
A single-beam spin-exchange relaxation-free atomic magnetometer is ultra-sensitive in the zero field, which has great potential for the detection of a magnetoencephalogram. The addition of a modulated magnetic field is an important approach to achieve high sensitivity for devices of this kind. In this study, we discovered that the amplitude and frequency of the modulated magnetic field (modulation index 0–3) both influence the light absorption. We defined this effect into a function by combining theoretical analysis and the results of experiments. It is discovered that the transmission intensity decreases with an increase in the modulation index. This effect is weakened under the application of a high modulation index. In addition, the transmission intensity and bias magnetic field no longer follow a strict Lorentz curve, while a high degree of fit can be achieved by applying the numerical solution of the Bloch function. A compact magnetometer with a volume of 10 cm3 and a sensitivity of 20 fT/Hz is developed based on the single beam scheme for the proof of concept. Our study is crucial in two aspects: (1) Obtaining high sensitivity through a short measurement period and (2) alignment of the scale factor of the individual magnetometer in a detection array, which further pave the way for improvement in a magnetometer’s performance under a variety of optics platforms.
Abstract The single-beam miniaturized atomic magnetometer with modulated magnetic field is one of the most capable approaches to biomagnetic measurements. The transmission intensity of the pumping beam is critical to the sensitivity of the magnetometer, which is affected by the density of alkali metal and the polarization of atomic spin. In this study, we investigated into the influence of three variables: the temperature of atomic vapour; the amplitude of the modulated magnetic field; the frequency of modulated magnetic field on the transmission intensity of pumping beam. We have defined their relationship into a function, and the calculated values through theoretical analysis have a high degree of fit with the measured values of numerous experiments. It is discovered that the transmission intensity decreases with the increase in temperature, and this effect is modified by the modulation index. A compact magnetometer is developed as a proof of concept based on single-beam scheme. The volume of this magnetometer is 10 cm 3 , and its dual axis sensitivity are both 30 fT/Hz 1 / 2 . Based on this relationship we find that two major improvements are achieved by separating the DC and AC components of transmission intensity: 1. Realizing closed-loop temperature control for atomic vapour which improved the stability of the magnetometer. 2. Achieving closed-loop dual axis magnetic measurements under a single-beam scheme, which extends the magnetometer’s scope of application.
Magnetic field gradients interfere with the coherence of the atomic ensemble and degrade the performance of the spin-exchange relaxation-free (SERF) atomic magnetometer. In this paper, the influence of magnetic field gradients is incorporated into the response model of single-beam atomic magnetometer, and the theoretical models of transverse relaxation rate, spin polarization and scale factor are established. Based on this model,we find that magnetic field gradients in different directions can cause varying degrees of degradation in the performance parameters of the magnetometer. The magnetic linewidths under different light power and magnetic field gradients are measured using the designed dedicated magnetic field gradients coils, and the spin polarization and magnetic field gradients relaxation rate are obtained through fitting. An unevenness and deviation of the curve are also observed in the experiments, indicating the presence of the magnetic field gradient of approximately 2 nT/cm in the magnetic shields. Furthermore, in a magnetic field gradient environment of 20 nT/cm, the mean of the long-term sensitivity decreased by 3.5 times and the standard deviation increased by 11 times. It shows that the magnetic field gradients will not only affect the signal-to-noise ratio, but also make the magnetometer more vulnerable to external interference when working. The sensitivity and stability of magnetometer will be greatly reduced. The research in this article provides a theoretical and experimental basis for eliminating the influence of magnetic field gradients and improving the accuracy of magnetic field measurements.
Atomic magnetometers are widely acknowledged as one of the most sensitive devices for magnetic field measurement. Our study presents a novel method that enables bandwidth expansion of single-beam magnetometers in the spin-exchange relaxation-free regime. This method bases on increasing the modulation amplitude of magnetic field combining with negative feedback with proportional gain. Through our method, the magnetometer’s total relaxation rate is moderately increased by elevating modulation amplitude and frequency, and correspondingly, the detection bandwidth experiences dramatic improvement from 230 Hz to 1380 Hz. The application of negative feedback with proportional gain further increases this bandwidth to higher than 4 kHz, which is over 17 times of its original value. The sensitivity of the magnetometer under this condition is measured as 25 fT/Hz1/2\text {Hz}^{\text {1/2}}Hz1/2for open-loop scheme and 35 fT/Hz1/2\text {Hz}^{\text {1/2}}Hz1/2for closed-loop scheme. Comparatively, the sensitivity measured on conventional conditions in our experiment is 12 fT/Hz1/2\text {Hz}^{\text {1/2}}Hz1/2. This approach offers a profitable trade-off that extraordinary expansion of detection bandwidth can be acquired with the price of a little sensitivity loss. Our method is advantageous for miniaturization of atomic magnetometers as no extra hardware is added, which is of special interest for applications including biomagnetic measurement where large detection bandwidth is sometimes in need.
A single-beam atomic magnetometer with elliptical polarization is simple in construction because it requires only one laser for both pumping and probing. When a small-signal magnetic field is input into the magnetometer after the DC magnetic field is set to zero, a full-wave cleared waveform is output. This characteristic is appropriate for calibration and measurement of DC magnetic fields, because the bias of such fields affects their sensitivity. In this paper, we examined the step-response waveform when a pulsed magnetic field with various DC magnetic-field biases was applied. The response waveform was measured in the time domain with an oscilloscope. The oscillation frequency did not depend on the step-magnetic-field difference but on the amplitude when changing from an absolute-zero magnetic field to a finite magnetic field. Because the DC magnetic field can be determined by measuring the frequency, the bias magnetic field of the atomic magnetometer can be adjusted to maintain the optimal point of operation.
Spin-exchange relaxation-free (SERF) atomic magnetometers operated under a near-zero magnetic field are used for vector magnetic field measurements with high sensitivity. Previously, the cross-axis coupling error evoked by a nonzero background magnetic field has been verified to be adverse in modulated single-beam magnetometers. Here, in a dual-beam unmodulated SERF magnetometer, we propose a somewhat different solution model for the cross-axis coupling effect where the field of interest couples with the interference field. Considering two cases where the transverse or longitudinal background field exists, the cross-axis coupling effect dependence on multiple factors is investigated here based on the dynamic response under a background magnetic field within ±5 nT. The theoretical and experimental investigation suggests that it has an adverse impact on the output response amplitude and phase and tilts the sensitive axis by several degrees, causing a measurement error on the dual-beam magnetometer. To suppress this effect, the background magnetic field is compensated through the PI closed-loop control. The coupling effect is effectively suppressed by 1.5 times at the 10–40 Hz low-frequency band and the sensitivity reaches 2.4 fT/Hz1/2.