Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Chinese Physics Letters

Close-Loop Bell–Bloom Magnetometer with Amplitude Modulation

Haichao Huang, Haifeng Dong, Hui-Jie Hao, Xuyang Hu

Published Sep 1, 2015• 13 citations
Publisher

Abstract

A high sensitive optical amplitude modulation magnetometer is investigated and demonstrated experimentally. We build an experimental platform for the atomic magnetometer and configure it as a Bell–Bloom magnetometer with amplitude modulation of 50% duty cycle square waveform. The open-loop input-output model is deduced from the Bloch equation and is verified experimentally. Instead of locking the frequency by using a voltage control oscillator, we realize a closed loop using the coils to generate a feedback field which avoids the stringent requirement of a high resolution frequency meter and markedly expands the dynamic range as well as the bandwidth. We realize an open loop sensitivity of 0.8 pT/Hz 1/2 at 20 Hz using a single light beam, which exceeds that of the state-of-the-art Bell–Bloom magnetometers, and the corresponding closed loop sensitivity is 1.2 pT/Hz 1/2 .

DOI
10.1088/0256-307x/32/9/098503

Related papers

Realization and Optimization of all-optical Cs atom magnetometer based on Bell-Bloom structure

Zhang Jun-ha

In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.

Journal of Optoelectronics·laser•Jan 1, 2015•0 citations

Study of the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers

Meiling Wang, Meng-Bing Wang, Guiying Zhang +1 more

We theoretically and experimentally study the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers. The theoretical and the experimental results are in good agreement for duty cycles and corresponding pumping rates ranging over 2 orders of magnitude. Our study gives the maximum field response as a function of duty cycle and pumping rate. Especially, for a fixed duty cycle, the maximum field response is obtained when the time averaged pumping rate, which is the product of pumping rate and duty cycle, is equal to the transverse relaxation rate in the dark. By using a combination of small duty cycle and large pumping rate, one can increase the maximum field response by up to a factor of 2 or π /2, relative to that of the sinusoidal modulation or the 50% duty cycle square-wave modulation respectively. We further show that the same pumping condition is also practically optimal for the sensitivity due to the fact that the signal at resonance is insensitive to the fluctuations of pumping rate and duty cycle.

Chinese Physics B•Jun 1, 2016•11 citations

Bandwidth Expansion Through Large-Amplitude Modulation and Proportional Feedback for Single-Beam Atomic Magnetometers

Kun Wang, Jixi Lu, Yeguang Yan +7 more

Atomic magnetometers are widely acknowledged as one of the most sensitive devices for magnetic field measurement. Our study presents a novel method that enables bandwidth expansion of single-beam magnetometers in the spin-exchange relaxation-free regime. This method bases on increasing the modulation amplitude of magnetic field combining with negative feedback with proportional gain. Through our method, the magnetometer’s total relaxation rate is moderately increased by elevating modulation amplitude and frequency, and correspondingly, the detection bandwidth experiences dramatic improvement from 230 Hz to 1380 Hz. The application of negative feedback with proportional gain further increases this bandwidth to higher than 4 kHz, which is over 17 times of its original value. The sensitivity of the magnetometer under this condition is measured as 25 fT/$\text {Hz}^{\text {1/2}}$for open-loop scheme and 35 fT/$\text {Hz}^{\text {1/2}}$for closed-loop scheme. Comparatively, the sensitivity measured on conventional conditions in our experiment is 12 fT/$\text {Hz}^{\text {1/2}}$. This approach offers a profitable trade-off that extraordinary expansion of detection bandwidth can be acquired with the price of a little sensitivity loss. Our method is advantageous for miniaturization of atomic magnetometers as no extra hardware is added, which is of special interest for applications including biomagnetic measurement where large detection bandwidth is sometimes in need.

IEEE Sensors Journal•Dec 16, 2021•18 citations

Faraday-rotation Bell–Bloom atomic magnetometer using an alternating pump–probe beam

Songsong Li, Yi Zhang, Yuan Tian +2 more

We propose a scheme for a Bell–Bloom atomic magnetometer based on a single beam. In our approach, the light is periodically modulated synchronously with Larmor precession. As a result, the light that interacts with atoms is alternately polychromatic and monochromatic. When the light is polychromatic, the ±1st sidebands of the light are optically resonant with the atoms, and the atoms are polarized by pumping. When the light is monochromatic, a differential detection technique extracts the Faraday-rotation signal of the light, and the polarization of the light is probed. We demonstrate an experimental implementation of the Bell–Bloom magnetometer that achieves a sensitivity for magnetic-field detection of 0.25 pT/Hz1/2 at 1 Hz. Our scheme is suitable for developing compact, miniaturized magnetometers.

Journal of Applied Physics•Aug 25, 2021•16 citations

Three-axis closed-loop optically pumped magnetometer operated in the SERF regime

Yeguang Yan, Jixi Lu, Shaowen Zhang +5 more

We propose a three-axis closed-loop optically pumped magnetometer with high sensitivity. The closed-loop magnetometer has a three-axis sensitivity of approximately 30 fT/Hz 1/2 using two orthogonal laser beams for pumping and probing the alkali metal atoms. In the closed-loop mode, the dynamic range is improved from ±5 nT to ±150 nT. The bandwidth is increased from about 100 Hz to over 2 kHz with 10 kHz modulation fields in x - and y -axes and another 6 kHz modulation field along the z -axis. Compared with single-axis or dual-axis magnetometers, the proposed magnetometer not only provides the direction and magnitude of the magnetic field but also has high robustness in a challenging environment. The magnetometer has applications in biomagnetic measurements, magnetic resonance imaging, and fundamental physics.

Optics Express•May 4, 2022•88 citations

Dual-Axis Closed Loop of a Single-Beam Atomic Magnetometer: Toward High Bandwidth and High Sensitivity

Junjian Tang, Yueyang Zhai, Binquan Zhou +2 more

Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.

IEEE Transactions on Instrumentation and Measurement•Jan 1, 2021•95 citations
A high sensitive optical amplitude modulation magnetometer is investigated and demonstrated experimentally. We build an experimental platform for the atomic magnetometer and configure it as a Bell–Bloom magnetometer with amplitude modulation of 50% duty cycle square waveform. The open-loop input-output model is deduced from the Bloch equation and is verified experimentally. Instead of locking the frequency by using a voltage control oscillator, we realize a closed loop using the coils to generate a feedback field which avoids the stringent requirement of a high resolution frequency meter and markedly expands the dynamic range as well as the bandwidth. We realize an open loop sensitivity of 0.8 pT/Hz 1/2 at 20 Hz using a single light beam, which exceeds that of the state-of-the-art Bell–Bloom magnetometers, and the corresponding closed loop sensitivity is 1.2 pT/Hz 1/2 .
In order to availably solve the crosstalk of the traditionally optically pumped magnetometer,in which an oscillating magnetic field drives transitions between Zeeman magnetic sublevels,an all-optical cesium(Cs)atomic magnetometer based on Bell-Bloom structure has been investigated and demonstrated experimentally in this paper.When there is an external magnetic field,by analyzing the Larmor precession spectrum of the polarized ground state atoms induced by a modulated pump laser,the atomic magnetometer with high sensitivity is achieved.First,we present the operating principle of the magnetometer with amplitude modulation and set up the experimental system by means of a three-layer magnetic shield.Then in the case of 100 nT field by optimizing the experimental parameters,i.e.,the frequency and intensity of the pump laser,we have obtained the atomic precession spectrum with line width(full width at half maximum)of 22 Hz and signal noise ratio(SNR)of 3.2×104 per unit hertz band width,and then have evaluated the magnetometer with an intrinsic sensitivity of 100fT/Hz1/2 and spatial resolution smaller than 1.2cm,while the experimentally closed loop test shows that the cesium atomic magnetometer would have the sensitivity of 120fT/Hz1/2 and response time of 300 ms.
We theoretically and experimentally study the optimal duty cycle and pumping rate for square-wave amplitude-modulated Bell–Bloom magnetometers. The theoretical and the experimental results are in good agreement for duty cycles and corresponding pumping rates ranging over 2 orders of magnitude. Our study gives the maximum field response as a function of duty cycle and pumping rate. Especially, for a fixed duty cycle, the maximum field response is obtained when the time averaged pumping rate, which is the product of pumping rate and duty cycle, is equal to the transverse relaxation rate in the dark. By using a combination of small duty cycle and large pumping rate, one can increase the maximum field response by up to a factor of 2 or π /2, relative to that of the sinusoidal modulation or the 50% duty cycle square-wave modulation respectively. We further show that the same pumping condition is also practically optimal for the sensitivity due to the fact that the signal at resonance is insensitive to the fluctuations of pumping rate and duty cycle.
Atomic magnetometers are widely acknowledged as one of the most sensitive devices for magnetic field measurement. Our study presents a novel method that enables bandwidth expansion of single-beam magnetometers in the spin-exchange relaxation-free regime. This method bases on increasing the modulation amplitude of magnetic field combining with negative feedback with proportional gain. Through our method, the magnetometer’s total relaxation rate is moderately increased by elevating modulation amplitude and frequency, and correspondingly, the detection bandwidth experiences dramatic improvement from 230 Hz to 1380 Hz. The application of negative feedback with proportional gain further increases this bandwidth to higher than 4 kHz, which is over 17 times of its original value. The sensitivity of the magnetometer under this condition is measured as 25 fT/Hz1/2\text {Hz}^{\text {1/2}}Hz1/2for open-loop scheme and 35 fT/Hz1/2\text {Hz}^{\text {1/2}}Hz1/2for closed-loop scheme. Comparatively, the sensitivity measured on conventional conditions in our experiment is 12 fT/Hz1/2\text {Hz}^{\text {1/2}}Hz1/2. This approach offers a profitable trade-off that extraordinary expansion of detection bandwidth can be acquired with the price of a little sensitivity loss. Our method is advantageous for miniaturization of atomic magnetometers as no extra hardware is added, which is of special interest for applications including biomagnetic measurement where large detection bandwidth is sometimes in need.
We propose a scheme for a Bell–Bloom atomic magnetometer based on a single beam. In our approach, the light is periodically modulated synchronously with Larmor precession. As a result, the light that interacts with atoms is alternately polychromatic and monochromatic. When the light is polychromatic, the ±1st sidebands of the light are optically resonant with the atoms, and the atoms are polarized by pumping. When the light is monochromatic, a differential detection technique extracts the Faraday-rotation signal of the light, and the polarization of the light is probed. We demonstrate an experimental implementation of the Bell–Bloom magnetometer that achieves a sensitivity for magnetic-field detection of 0.25 pT/Hz1/2 at 1 Hz. Our scheme is suitable for developing compact, miniaturized magnetometers.
We propose a three-axis closed-loop optically pumped magnetometer with high sensitivity. The closed-loop magnetometer has a three-axis sensitivity of approximately 30 fT/Hz 1/2 using two orthogonal laser beams for pumping and probing the alkali metal atoms. In the closed-loop mode, the dynamic range is improved from ±5 nT to ±150 nT. The bandwidth is increased from about 100 Hz to over 2 kHz with 10 kHz modulation fields in x - and y -axes and another 6 kHz modulation field along the z -axis. Compared with single-axis or dual-axis magnetometers, the proposed magnetometer not only provides the direction and magnitude of the magnetic field but also has high robustness in a challenging environment. The magnetometer has applications in biomagnetic measurements, magnetic resonance imaging, and fundamental physics.
Atomic magnetometers operated in spin-exchange relaxation-free (SERF) have the potential to replace superconducting quantum interference devices (SQUIDs) in the field of biomagnetism. Here, we demonstrate the dual-axis closed-loop control of a single-beam SERF magnetometer that allows sensing of two orthogonal magnetic fields simultaneously and independently with suppressed cross-talk effect, achieved by applying a rotating modulation field and using of the negative feedback. Operating in the dual-axis closed-loop mode with a miniature 4 × 4 × 4 mm 87Rb cell, we achieve magnetic field sensitivity of 20 fT/Hz1/2 and a bandwidth of 1.8 kHz. In addition to the experimental study of the sensitivity and bandwidth, we perform a theoretical analysis to the dual-axis response and develop an effective decoupling method. The implementation of closed-loop control enables the magnetometer to be robust against the disturbance of the ambient field, which could enlarge the dynamic range, enhance the systematic stability, and suppress the cross-talk effect. Such a simple, yet high-performance SERF magnetometer could be suitable as a promising candidate in the field of biomagnetism, allowing for a denser sensor array and opening up new possibilities for the noninvasive biomagnetic imaging.