Conference on Lasers and Electro-Optics

Quantum Measurement of a Mechanical Resonator At and Below the Standard Quantum Limit

Massimiliano Rossi, David Mason, Junxin Chen, Yeghishe Tsaturyan, Albert Schließer

Published Jan 1, 2019• 0 citations
Publisher
DOI
10.1364/cleo_qels.2019.fm1a.3

Related papers

Quantum Measurement of a Mechanical Resonator at and Below the Standard Quantum Limit

Massimiliano Rossi, David Mason, Junxin Chen +2 more

Interferometrie techniques to measure mechanical displacement are subject to constraints ultimately governed by quantum mechanics. In a "standard" measurement of a mechanically induced optical phase shift, there exists a trade-off between measurement imprecision and motion disturbance, known as standard quantum limit (SQL) [1]. For a mechanical resonator with susceptibility χm(Ω), this limit is SSQL(Ω) = ħ|χm(Ω)| (ħ reduced Planck constant), at any frequency Ω. In the last half-century, a number of systems, including advanced LIGO and ultracold atoms have progressed towards this limit, but excess sources of noise have yet prevented fully reaching the SQL. Here, we show measurements of an ultracoherent mechanical resonator performed at the SQL within 33% [2] and, for the first time, below the SQL by 1.5 dB[3]. The latter has been possible by a non-standard measurement scheme that explois quantum correlations between optical quadratures induced in the optomechanical device.

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)•Jun 1, 2019•1 citation

Mechanical resonators and quantum measurements

Hiroshi Yamaguchi

The Japan Society of Applied Physics•Jul 8, 2014•0 citations

Quantum Limits on Measurement and Control of a Mechanical Oscillator

Vivishek Sudhir

Springer theses•Nov 22, 2017•3 citations

Quantum Measurement of a Mechanical Resonator at and Below the Standard Quantum Limit

Massimiliano Rossi, David L. Mason, Junxin Chen +2 more

We measure mechanical displacements within 35% of the Heisenberg limit. By exploiting quantum correlations in an optomechanical system, we achieve for the first time a total sensitivity below the standard quantum limit by 1.5 dB. © 2019 The Author(s)

Conference on Lasers and Electro-Optics•May 1, 2019•0 citations

Properties of a monolithic sapphire parametric transducer: prospects of measuring the standard quantum limit

Clayton R. Locke, Michael Edmund Tobar, Eugene N. Ivanov

To measure the standard quantum limit (SQL) a high quality transducer must be coupled to a high quality mechanical system. Due to its monolithic nature, the monolithic sapphire transducer (MST) has high quality factors for both types of resonances. Single loop suspension is shown to yield a mechanical quality factor of 6.10^8 at 4 K. From standard analysis we show the MST has the potential to measure noise fluctuations of the mechanical oscillator at the SQL. also, we point out a new way to determine if the transducer back action is quantum limited. We show that if the fluctuations are at the quantum limit, then the amplitude of the oscillation will be amplified by the ratio of the ringdown time to the measurement time, which is an inherently easier measurement.

arXiv:gr-qc/0207075•Classical and Quantum Gravity•Mar 19, 2002•9 citations

Testing Quantum Mechanics in a Mechanical System: Characterizing Mechanical Resonators

Santa Bárbara

•Jan 1, 2009•0 citations
Interferometrie techniques to measure mechanical displacement are subject to constraints ultimately governed by quantum mechanics. In a "standard" measurement of a mechanically induced optical phase shift, there exists a trade-off between measurement imprecision and motion disturbance, known as standard quantum limit (SQL) [1]. For a mechanical resonator with susceptibility χm(Ω), this limit is SSQL(Ω) = ħ|χm(Ω)| (ħ reduced Planck constant), at any frequency Ω. In the last half-century, a number of systems, including advanced LIGO and ultracold atoms have progressed towards this limit, but excess sources of noise have yet prevented fully reaching the SQL. Here, we show measurements of an ultracoherent mechanical resonator performed at the SQL within 33% [2] and, for the first time, below the SQL by 1.5 dB[3]. The latter has been possible by a non-standard measurement scheme that explois quantum correlations between optical quadratures induced in the optomechanical device.
To measure the standard quantum limit (SQL) a high quality transducer must be coupled to a high quality mechanical system. Due to its monolithic nature, the monolithic sapphire transducer (MST) has high quality factors for both types of resonances. Single loop suspension is shown to yield a mechanical quality factor of 6.10^8 at 4 K. From standard analysis we show the MST has the potential to measure noise fluctuations of the mechanical oscillator at the SQL. also, we point out a new way to determine if the transducer back action is quantum limited. We show that if the fluctuations are at the quantum limit, then the amplitude of the oscillation will be amplified by the ratio of the ringdown time to the measurement time, which is an inherently easier measurement.