Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Springer theses

Quantum Limits on Measurement and Control of a Mechanical Oscillator

Vivishek Sudhir

Published Nov 22, 2017• 3 citations
Publisher
DOI
10.1007/978-3-319-69431-3

Related papers

Measurement and control of a mechanical oscillator at its thermal decoherence rate 1 DALZIEL WILSON, VIVISHEK SUDHIR, NICOLAS PIRO,

Ryan Schilling, Amir Hossein Ghadimi, Tobias Jan Kippenberg +1 more

cavityoptomechanical coupling, and realizes a measurement of the oscillator’s displacement with an imprecision 40 dB below that at the standard quantum limit, while maintaining an imprecision-backaction product within a factor of 5 of the Heisenberg uncertainty limit. As a demonstration of its utility, we use the measurement to feedback cool the oscillator to an phonon occupation of 5.4 0.7 (i.e, a ground state probablity of 16%). Our results establish a new benchmark for the performance of a linear position sensor, and signal the emergence of engineered mechanical oscillators as practical subjects for measurement-based quantum control.

•Jan 1, 2014•16 citations

Quantum control of mechanical oscillators

Konrad W. Lehnert

Bulletin of the American Physical Society•Feb 27, 2012•0 citations

Measurement-based quantum control of mechanical motion

Massimiliano Rossi, David Mason, Junxin Chen +2 more

arXiv:1805.05087•Nature•Oct 25, 2018•444 citations

Quantum limits on measurement and control of a mechanical oscillator

Vivishek Sudhir

The motion of a macroscopic mechanical oscillator – a glass nanostring – has been measured, using a cavity-enhanced optical interferometer, with a sensitivity that is 40 dB below that at the standard quantum limit, forming the most precise measurement of the zero-point motion of a mechanical oscillator yet. The resulting back-action due to the measurement has been observed. A quantum feedback protocol is used to cancel 20 dB of back-action, in a first instance of quantum feedback applied on a mechanical oscillator. Quantum correlations developed between the oscillator and the measuring instrument – light – has been observed. The role of these correlations in quantum-enhanced metrology of weak forces is illustrated, and feedback is used to manipulate and enhance the same correlations.

Frontiers in Optics•Jan 1, 2017•2 citations

Microwave Electromechanics: Measuring and Manipulating the Quantum State of a Macroscopic Mechanical Oscillator

Jennifer Harlow

In the past several years, the field of optomechanics has progressed from proof-of-principle experiments to the realization of mechanical oscillators and measurements in the quantum regime. Mechanical oscillators are of great interest because they can have small dissipation rates, can couple to many different systems of interest, and are the fundamental elements of ultrasensitive force detectors. Coupling these mechanical oscillators to microwave or optical fields provides a twofold advantage. Firstly, information about mechanical position can be encoded in the interrogating field, enabling sensitive readout of the mechanical oscillator. Secondly, the radiation pressure force of that field can be used to control the state of the mechanical oscillator. Including a high-quality microwave or optical cavity enhances both of these effects, as the field strength is resonantly increased.\nThe major questions in the field of optomechanics in the last several years have dealt with using mechanical oscillators for ultrasensitive measurements and as tools for quantum information. Both of these goals have the prerequisite that we be able to read out the motion of the mechanical oscillator in a quantum efficient manner. To that end, we developed a nearly shot-noise limited microwave interferometer capable of measuring mechanical motion with an imprecision below that at the standard quantum limit. This achievement is not only a critical improvement for the electromechanical experiments we do, but is also an important tool for any experiment that encodes the information of interest in microwave fields. In order to use mechanical oscillators as tools for quantum information, the mechanical oscillator must also be cooled into the quantum regime and fully controllable by the interrogating fields. To this end, we used the radiation pressure of microwave fields to cool our macroscopic mechanical oscillator to less than one phonon. We also demonstrated coherent transfer between itinerant microwave states and the mechanical oscillator, even for incident fields with less than one photon of energy.\nThese accomplishments have set the foundation for further experiments to extend the quantum information abilities of optomechanical systems, couple diverse quantum systems via a mechanical intermediary, and potentially explore the foundations of quantum mechanics at macroscopic scales.

•Jan 1, 2013•4 citations

Quantum Control Based on Measurement

Gerard J Milburn

Springer eBooks•Jan 1, 2014•1 citation
cavityoptomechanical coupling, and realizes a measurement of the oscillator’s displacement with an imprecision 40 dB below that at the standard quantum limit, while maintaining an imprecision-backaction product within a factor of 5 of the Heisenberg uncertainty limit. As a demonstration of its utility, we use the measurement to feedback cool the oscillator to an phonon occupation of 5.4 0.7 (i.e, a ground state probablity of 16%). Our results establish a new benchmark for the performance of a linear position sensor, and signal the emergence of engineered mechanical oscillators as practical subjects for measurement-based quantum control.
The motion of a macroscopic mechanical oscillator – a glass nanostring – has been measured, using a cavity-enhanced optical interferometer, with a sensitivity that is 40 dB below that at the standard quantum limit, forming the most precise measurement of the zero-point motion of a mechanical oscillator yet. The resulting back-action due to the measurement has been observed. A quantum feedback protocol is used to cancel 20 dB of back-action, in a first instance of quantum feedback applied on a mechanical oscillator. Quantum correlations developed between the oscillator and the measuring instrument – light – has been observed. The role of these correlations in quantum-enhanced metrology of weak forces is illustrated, and feedback is used to manipulate and enhance the same correlations.
In the past several years, the field of optomechanics has progressed from proof-of-principle experiments to the realization of mechanical oscillators and measurements in the quantum regime. Mechanical oscillators are of great interest because they can have small dissipation rates, can couple to many different systems of interest, and are the fundamental elements of ultrasensitive force detectors. Coupling these mechanical oscillators to microwave or optical fields provides a twofold advantage. Firstly, information about mechanical position can be encoded in the interrogating field, enabling sensitive readout of the mechanical oscillator. Secondly, the radiation pressure force of that field can be used to control the state of the mechanical oscillator. Including a high-quality microwave or optical cavity enhances both of these effects, as the field strength is resonantly increased.\nThe major questions in the field of optomechanics in the last several years have dealt with using mechanical oscillators for ultrasensitive measurements and as tools for quantum information. Both of these goals have the prerequisite that we be able to read out the motion of the mechanical oscillator in a quantum efficient manner. To that end, we developed a nearly shot-noise limited microwave interferometer capable of measuring mechanical motion with an imprecision below that at the standard quantum limit. This achievement is not only a critical improvement for the electromechanical experiments we do, but is also an important tool for any experiment that encodes the information of interest in microwave fields. In order to use mechanical oscillators as tools for quantum information, the mechanical oscillator must also be cooled into the quantum regime and fully controllable by the interrogating fields. To this end, we used the radiation pressure of microwave fields to cool our macroscopic mechanical oscillator to less than one phonon. We also demonstrated coherent transfer between itinerant microwave states and the mechanical oscillator, even for incident fields with less than one photon of energy.\nThese accomplishments have set the foundation for further experiments to extend the quantum information abilities of optomechanical systems, couple diverse quantum systems via a mechanical intermediary, and potentially explore the foundations of quantum mechanics at macroscopic scales.