Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Conference on Lasers and Electro-Optics Europe & European Quantum Electronics Conference (CLEO/Europe-EQEC)

Quantum Measurement of a Mechanical Resonator at and Below the Standard Quantum Limit

Massimiliano Rossi, David Mason, Junxin Chen, Yeghishe Tsaturyan, Albert Schließer

Published Jun 1, 2019• 1 citation
Publisher

Abstract

Interferometrie techniques to measure mechanical displacement are subject to constraints ultimately governed by quantum mechanics. In a "standard" measurement of a mechanically induced optical phase shift, there exists a trade-off between measurement imprecision and motion disturbance, known as standard quantum limit (SQL) [1]. For a mechanical resonator with susceptibility χm(Ω), this limit is SSQL(Ω) = ħ|χm(Ω)| (ħ reduced Planck constant), at any frequency Ω. In the last half-century, a number of systems, including advanced LIGO and ultracold atoms have progressed towards this limit, but excess sources of noise have yet prevented fully reaching the SQL. Here, we show measurements of an ultracoherent mechanical resonator performed at the SQL within 33% [2] and, for the first time, below the SQL by 1.5 dB[3]. The latter has been possible by a non-standard measurement scheme that explois quantum correlations between optical quadratures induced in the optomechanical device.

DOI
10.1109/cleoe-eqec.2019.8872312

Related papers

Measuring Motion Below the Standard Quantum Limit by Strong Optomechanical Quantum Correlations

Junxin Chen, David Mason, Massimiliano Rossi +2 more

In interferometric displacement and force measurement, the tradeoff between imprecision noise and quantum backaction sets the standard quantum limit (SQL). By exploiting quantum correlations in an optomechanical system, we demonstrate the first sub-SQL interferometric measurement.

Quantum Information and Measurement (QIM)•Jan 1, 2019•0 citations

Quantum Measurement of a Mechanical Resonator at and Below the Standard Quantum Limit

Massimiliano Rossi, David L. Mason, Junxin Chen +2 more

We measure mechanical displacements within 35% of the Heisenberg limit. By exploiting quantum correlations in an optomechanical system, we achieve for the first time a total sensitivity below the standard quantum limit by 1.5 dB. © 2019 The Author(s)

Conference on Lasers and Electro-Optics•May 1, 2019•0 citations

Optically measuring force near the standard quantum limit

Sydney Schreppler, Nicolas Spethmann, Nathan Brahms +3 more

The Heisenberg uncertainty principle sets a lower bound on the noise in a force measurement based on continuously detecting a mechanical oscillator's position. This bound, the standard quantum limit, can be reached when the oscillator subjected to the force is unperturbed by its environment and when measurement imprecision from photon shot noise is balanced against disturbance from measurement back-action. We applied an external force to the center-of-mass motion of an ultracold atom cloud in a high-finesse optical cavity and measured the resulting motion optically. When the driving force is resonant with the cloud's oscillation frequency, we achieve a sensitivity that is a factor of 4 above the standard quantum limit and consistent with theoretical predictions given the atoms' residual thermal disturbance and the photodetection quantum efficiency.

arXiv:1312.4896•Science•Jun 26, 2014•167 citations

Measuring nanomechanical motion with an imprecision below the standard quantum limit

G. Anetsberger, E. Gavartin, O. Arcizet +5 more

We report a room-temperature measurement of nanomechanical motion with an imprecision below the standard quantum limit (SQL), using cavity-enhanced optical near fields. Fundamental thermodynamical cavity frequency fluctuation limits the total imprecision to $3 \mathrm{dB}$ below the SQL at room temperature [corresponding to $(530 \mathrm{am}/\sqrt{\mathrm{Hz}}){}^{2}$ in absolute units] and is expected to reduce to negligible values at moderate cryogenic temperatures. Coupling strengths exceeding those required to reach the SQL by more than two orders of magnitude are achieved, allowing a shot-noise limited imprecision more than $10 \mathrm{dB}$ below the SQL. The transducer, thus, in principle, allows access to the quantum backaction dominated regime, a prerequisite for exploring quantum backaction, measurement-induced squeezing, and obtaining sub-SQL sensitivity using backaction evading techniques.

arXiv:1003.3752•Physical Review A•Dec 29, 2010•156 citations

Quantum Measurement of Mechanical Motion close to the Standard Quantum Limit

Liu Qiu

In quantum mechanics, the Heisenberg uncertainty principle places a fundamental limit in the measurement precision for certain pairs of physical quantities, such as position and momentum, time and energy or amplitude and phase. Due to the Heisenberg uncertainty principle, any attempt to extract certain information from a quantum object would inevitably perturbitinanunpredictableway. This raises one question,"What is the precision limit in such quantum measurements?" The answer, standard quantum limit (SQL), has been obtained by Braginsky to figure out the fundamental quantum limits of displacement measurement in the context of gravitational wave detection. To circumvent the unavoidable quantum back-action from the priori measurement, quantum non-demolition measurement (QND) methods were introduced by Braginsky and Thorne. To surpass the SQL of the displacement measurement in an interferometer, one can measure only one quadrature of the mechanical motion while give up the information about the other canonically conjugated quadrature. Such measurements can be performed by periodic driving the mechanical oscillator, i.e. the back-action evading (BAE) measurement. Cavity optomechanics provides an ideal table-top platform for the testing of the quantum measurement theory. Mechanical oscillator is coupled to electromagnetic field via radiation pressure, which is enhanced by an optical micro-cavity. Over the last decade, laser cooling has enabled the preparation of mechanical oscillator in the ground state in both optical and microwave systems. BAE measurements of mechanical motion have been allowed in the microwave electromechanical systems, which led to the observations of mechanical squeezing and entanglement. However, despite the theoretical proposal almost 40 years ago, the sub-SQL measurements still remain elusive. This thesis reports our efforts approach the sub-SQL with a highly sideband-resolved silicon optomechanical crystal (OMC) in a 3He buffer gas environment at 2K. The OMC couples an optical mode at telecommunication wavelengths and a colocalized mechanical mode at GHz frequencies. The Helium3 buffer gas environment allows sufficient thermalization of the OMC despite the drastically decreased silicon thermal conductivity. We observe Floquet dynamics in motional sideband asymmetry measurement when employing multiple probe tones. The Floquet dynamics arises due to presence of Kerr-type nonlinearities and gives rise to an artificially modified motional sideband asymmetry, resulting from a synthetic gauge field among the Fourier modes. We demonstrate the first optical continuous two-tone backaction-evading measurement of a localized GHz frequency mechanical mode of silicon OMC close to the ground state by showing the transition from conventional sideband asymmetry to backaction-evading measurement. We discover a fundamental two-tone optomechanical instability and demonstrate its implications on the back-action evading measurement. Such instability imposes a fundamental limitation on other two-tone schemes, such as dissipative quantum mechanical squeezing. We demonstrate state-of-art laser sideband cooling of the mechanical motion to a mean thermal occupancy of 0.09 quantum, which is 7.4dB of the oscillator's zero-point energy and corresponds to 92% ground state probability. This also enables us to observe the dissipative mechanical squeezing below the zero-point motion for the first time with laser light.

•Jan 1, 2020•1 citation

Ultrasensitive displacement measurement with nonlinear optomechanical coupling and squeezed light injection

Doudou Wang, Quansen Wang, Qiang Zhang +1 more

We propose an ultrasensitive displacement measurement scheme to overcome the standard quantum limit (SQL) in the unresolved sideband cavity optomechanical system with nonlinear optomechanical coupling and squeezed light injection. By introducing the optimized quantum correlation, which is enabled by suitable choices of the squeezing angle, squeezing level, power of the probe light, and measurement angle of homodyne detection, the off-resonant displacement sensitivity reaches 6 dB below the SQL in linear optomechanical coupling. In contrast, displacement sensitivities with a coherent probe plus variational readout and squeezed probe plus fixed measurement angle (phase quadrature) are 2.6 dB and 4.6 dB below the SQL, respectively. By combining linear and quadratic optomechanical coupling, we show that the displacement sensitivity can be further improved to 9.6 dB below the SQL. Our results have potential applications in gravitational-wave detectors, quantum metrology, and the search for dark matter.

Journal of the Optical Society of America B•Jan 13, 2023•4 citations
Interferometrie techniques to measure mechanical displacement are subject to constraints ultimately governed by quantum mechanics. In a "standard" measurement of a mechanically induced optical phase shift, there exists a trade-off between measurement imprecision and motion disturbance, known as standard quantum limit (SQL) [1]. For a mechanical resonator with susceptibility χm(Ω), this limit is SSQL(Ω) = ħ|χm(Ω)| (ħ reduced Planck constant), at any frequency Ω. In the last half-century, a number of systems, including advanced LIGO and ultracold atoms have progressed towards this limit, but excess sources of noise have yet prevented fully reaching the SQL. Here, we show measurements of an ultracoherent mechanical resonator performed at the SQL within 33% [2] and, for the first time, below the SQL by 1.5 dB[3]. The latter has been possible by a non-standard measurement scheme that explois quantum correlations between optical quadratures induced in the optomechanical device.
The Heisenberg uncertainty principle sets a lower bound on the noise in a force measurement based on continuously detecting a mechanical oscillator's position. This bound, the standard quantum limit, can be reached when the oscillator subjected to the force is unperturbed by its environment and when measurement imprecision from photon shot noise is balanced against disturbance from measurement back-action. We applied an external force to the center-of-mass motion of an ultracold atom cloud in a high-finesse optical cavity and measured the resulting motion optically. When the driving force is resonant with the cloud's oscillation frequency, we achieve a sensitivity that is a factor of 4 above the standard quantum limit and consistent with theoretical predictions given the atoms' residual thermal disturbance and the photodetection quantum efficiency.
We report a room-temperature measurement of nanomechanical motion with an imprecision below the standard quantum limit (SQL), using cavity-enhanced optical near fields. Fundamental thermodynamical cavity frequency fluctuation limits the total imprecision to 3dB3 \mathrm{dB}3dB below the SQL at room temperature [corresponding to (530am/Hz)2(530 \mathrm{am}/\sqrt{\mathrm{Hz}}){}^{2}(530am/Hz​)2 in absolute units] and is expected to reduce to negligible values at moderate cryogenic temperatures. Coupling strengths exceeding those required to reach the SQL by more than two orders of magnitude are achieved, allowing a shot-noise limited imprecision more than 10dB10 \mathrm{dB}10dB below the SQL. The transducer, thus, in principle, allows access to the quantum backaction dominated regime, a prerequisite for exploring quantum backaction, measurement-induced squeezing, and obtaining sub-SQL sensitivity using backaction evading techniques.
In quantum mechanics, the Heisenberg uncertainty principle places a fundamental limit in the measurement precision for certain pairs of physical quantities, such as position and momentum, time and energy or amplitude and phase. Due to the Heisenberg uncertainty principle, any attempt to extract certain information from a quantum object would inevitably perturbitinanunpredictableway. This raises one question,"What is the precision limit in such quantum measurements?" The answer, standard quantum limit (SQL), has been obtained by Braginsky to figure out the fundamental quantum limits of displacement measurement in the context of gravitational wave detection. To circumvent the unavoidable quantum back-action from the priori measurement, quantum non-demolition measurement (QND) methods were introduced by Braginsky and Thorne. To surpass the SQL of the displacement measurement in an interferometer, one can measure only one quadrature of the mechanical motion while give up the information about the other canonically conjugated quadrature. Such measurements can be performed by periodic driving the mechanical oscillator, i.e. the back-action evading (BAE) measurement. Cavity optomechanics provides an ideal table-top platform for the testing of the quantum measurement theory. Mechanical oscillator is coupled to electromagnetic field via radiation pressure, which is enhanced by an optical micro-cavity. Over the last decade, laser cooling has enabled the preparation of mechanical oscillator in the ground state in both optical and microwave systems. BAE measurements of mechanical motion have been allowed in the microwave electromechanical systems, which led to the observations of mechanical squeezing and entanglement. However, despite the theoretical proposal almost 40 years ago, the sub-SQL measurements still remain elusive. This thesis reports our efforts approach the sub-SQL with a highly sideband-resolved silicon optomechanical crystal (OMC) in a 3He buffer gas environment at 2K. The OMC couples an optical mode at telecommunication wavelengths and a colocalized mechanical mode at GHz frequencies. The Helium3 buffer gas environment allows sufficient thermalization of the OMC despite the drastically decreased silicon thermal conductivity. We observe Floquet dynamics in motional sideband asymmetry measurement when employing multiple probe tones. The Floquet dynamics arises due to presence of Kerr-type nonlinearities and gives rise to an artificially modified motional sideband asymmetry, resulting from a synthetic gauge field among the Fourier modes. We demonstrate the first optical continuous two-tone backaction-evading measurement of a localized GHz frequency mechanical mode of silicon OMC close to the ground state by showing the transition from conventional sideband asymmetry to backaction-evading measurement. We discover a fundamental two-tone optomechanical instability and demonstrate its implications on the back-action evading measurement. Such instability imposes a fundamental limitation on other two-tone schemes, such as dissipative quantum mechanical squeezing. We demonstrate state-of-art laser sideband cooling of the mechanical motion to a mean thermal occupancy of 0.09 quantum, which is 7.4dB of the oscillator's zero-point energy and corresponds to 92% ground state probability. This also enables us to observe the dissipative mechanical squeezing below the zero-point motion for the first time with laser light.
We propose an ultrasensitive displacement measurement scheme to overcome the standard quantum limit (SQL) in the unresolved sideband cavity optomechanical system with nonlinear optomechanical coupling and squeezed light injection. By introducing the optimized quantum correlation, which is enabled by suitable choices of the squeezing angle, squeezing level, power of the probe light, and measurement angle of homodyne detection, the off-resonant displacement sensitivity reaches 6 dB below the SQL in linear optomechanical coupling. In contrast, displacement sensitivities with a coherent probe plus variational readout and squeezed probe plus fixed measurement angle (phase quadrature) are 2.6 dB and 4.6 dB below the SQL, respectively. By combining linear and quadratic optomechanical coupling, we show that the displacement sensitivity can be further improved to 9.6 dB below the SQL. Our results have potential applications in gravitational-wave detectors, quantum metrology, and the search for dark matter.