Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

CRC Press eBooks

Concluding Observations

Cyril Bernard Lucas

Published Nov 27, 2013• 0 citations
Publisher

Abstract

In Section 1.1 we introduced the subject of atomic and molecular beam formation by stating that a beam with a cosine distribution is obtained when the beam-forming impedance is a circular orice and that a narrow slit has also been employed to produce an improved beam. Most relevant theoretical papers use the convention of referring to ‘molecules’ for both atoms and molecules, but we continue to retain the consistent use of ‘atoms’ to mean both atoms and molecules unless a distinction is necessary. Following the introduction of the basic equations of the kinetic theory of gases in Section 2.2, the relatively simple expressions for the beam formed by an orice were introduced in Section 2.3. It was also mentioned in Section 1.1 that when the impedance is a single tube a much narrower collimated beam is obtained and that by employing an array of tubes a greatly improved beam intensity is obtained. In this chapter we present the theory of beam formation to include the more difcult case of ow through a tube. We only briey mention calculations that only apply when Γ ≤ 10 where Γ is the ratio of length l to diameter d (Section 2.5). These are of little interest for atomic beam formation, but are needed for calculations of Knudsen cell operation, which are outside the scope of this work. Following the discussion of the basic theory, we present in the next chapter simplications that make the design of an atomic beam and the predictions of its performance easier. However, we warn that an extensive comparison of theoretical results with experiment in Chapter 11 points to an unsatisfactory disagreement between theory and experiment for the beam halfwidth, especially in the case of gaseous rather than vapour beams and also particularly when the beam-forming impedance is a focussing capillary array.

DOI
10.1201/b16345-14

Related papers

Theory of Collimated Atomic Beam Formation

Cyril Bernard Lucas

If a beam is to be produced from a material that is solid or liquid at laboratory temperature, then it must be converted to a vapour in an oven before it passes through the beam-forming impedance. In the reviews mentioned in Section 1.2, the approach has usually been to give details of numerous designs. In this chapter, we discuss the general design principles, and then the next two chapters become more of a reference source for the evaporation of different substances. We thus include the experience of a large number of experimenters who have needed to heat a liquid or solid substance to form it into an atomic or molecular beam. If the material can be evaporated and raised to a temperature to give the required input pressure at the input to the impedance at a temperature less than about 1500 K, it is usual to describe the heating device as an oven. At higher temperatures, the device is usually called a furnace, but the distinction is not really necessary. Hence we will avoid the term except for thermal dissociation of a molecular species, discussed in Chapter 6, when very high temperatures are usually needed, so a furnace is a more appropriate term. For convenience we will also term a completely different approach, namely, the evaporation of the material by direct electron beam heating of the surface (Section 3.2.5) as an oven. ‘Crucible’ is used by many authors interchangeably with ‘oven,’ but it often implies a container for the material to be evaporated that is placed within a heated envelope.

CRC Press eBooks•Nov 27, 2013•0 citations

CONSIDERATIONS AFFECTING THE DESIGN OF ATOMIC - AND MOLECULAR-BEAM APPARATUS

Douglas W. McColm

•May 17, 1965•0 citations

Atomic and Molecular Beams: The State of the Art 2000

Tosi, Paolo, Bassi, Davide

Springer eBooks•Jan 1, 2001•181 citations

Atomic beam source for the ultracold focused ion beam setup

Brenda R. J. Jansen

In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further. In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further.

•Jan 1, 2013•0 citations

A Source of Translationally Cold Molecular Beams

Laszlo C. Sarkozy

Currently the fields studying or using molecules with low kinetic energies are experiencing an unprecedented growth.Astronomers and chemists are interested in chemical reactions taking place at temperatures below or around 20 K, spectroscopists could make very precise measurements on slow molecules and molecular physicists could chart the potential energy surfaces more accurately.And the list continues.All of these experiments need slow molecules, with kinetic energies from around 10 cm -1 down to 0. Several designs of cold sources have already been made.The most interesting ones are presented.This work describes the design and the testing of a cold source based on the collisional cooling technique: the molecules of interest are cooled well below their freezing point by a precooled buffer gas.This way condensation is avoided.The source is a copper cell cooled to 4.2 K by an external liquid helium bath.The cell is filled with cold buffer gas (helium).The molecules of choice (ammonia) are injected through a narrow tube in the middle of the cell.The cold molecules leave the cell through a 1 millimeter hole.Two versions of pulsing techniques have been employed: a shutter blade which covers the source hole and opens it only for short moments, and a chopper that modulates the beam further downstream.Both produced pulse lengths around 1 millisecond.The source is tested in an experiment in which the emerging molecules are focused and detected.Time of flight technique is used to measure the kinetic energies.Two detectors have been employed: a microwave cavity to analyze the state of the molecules in the beam, and a mass spectrometer to measure the number density of the particles.The molecules coming out of the source hole are formed into a beam by an electrostatic quadrupole state selector.The quantum mechanical aspects and the elements of electrodynamics involved in the focusing are described.A computer simulation program is presented, which helped calculate the trajectories of the molecules from source to the final detector.The simulations revealed interesting artifacts the focuser can make: if a short state selector is used, the speed distribution of the beam arriving at the detector is strongly modulated by a "focuser transfer function".The essence of the phenomenon is caused by the inability of the focuser to focus all speed at the same time: a few velocity groups are well focused, while many others are defocused.The transfer functions gained from the simulations were used to correctly interpret the detector signal.iii The design of the microwave cavity (Fabry-Perot) and its driving electronics is presented.Due to unavoidable noises present in the circuit, the use of this detector was limited to the preliminary experiments.A simple, commercial mass spectrometer was used.To improve its characteristics, a few modifications have been made.With the improved version, only the water background (an interfering signal at mass 17 amu) was disturbing the signal.A liquid nitrogen trap has been used to minimize the background.The experimental measurements revealed several undesired effects accompanying the production of the slow beam: cluster formation, snow accumulation inside the cell and very high sensitivity to the balance of the two gas pressures.Clusters made up the majority of the emitted particles.Switching from the shutter-blade pulsing (closed cell) to the chopper modulation (open cell) improved the ratio of the useful molecules in the beam significantly.The snow accumulation limited the useful experimenting time to around 20 minutes.After this the accumulated ammonia snow either perturbed the signal significantly or obstructed the source hole completely.A very high sensitivity to the ratio of the buffer gas pressure to the ammonia injection rate has been noticed.A 30% deviation from the optimum value can change the speed distribution and the amount of emitted molecules completely.The stabilization of the ballast pressures was necessary.The beam obtained in the optimal regime of the source cell is presented and analyzed.The characteristic values of most interest in a future collision experiment are the following: the speed distribution of the beam at the detector has a height of the order of 10 5 molecules per unit speed interval and per pulse; the useful speed interval is from 55 m/s to 500 m/s.iv Dedicated to my wife, Magdi.v ACKNOWLEDGMENTS According to an East European folktale a king wanted to find out how much his daughters loved him.When the smallest princess answered "I love you like salt", the angry king banished her from the kingdom.It was only later, when the kingdom was totally deprived of salt, that he realized the real value of his daughter's words.I believe it was the salt of science that I received from my advisor, Frank De Lucia.His endless optimism always kept me going forward and taught me how to deal with difficulties now and in the future.He always made himself available, and never let me go without an excellent idea or a piece of advice.An exceptional scientist and a wonderful man, he will always be the distant example to follow in my scientific career.Gregory Lafyatis also deserves my gratitude for his insights into many of the theoretical aspects of my research.The instruments he lent me made my work in the lab much easier.I also thank Joe Demers for helping me in the lab at the most difficult time: the beginning.I am very thankful to my colleagues, Ivan Medvedev and David Graff for being always interested in my work and giving me valuable ideas.I am especially grateful to Christopher Neese for helping me with LabView related problems at a crucial moment of my research.I wish to thank Kent Ludwig for his tedious work on the low-temperature components of the experimental setup.Tom Kelch, advisor in the student mechanical shop, always had the right solution to the mechanical engineering problems I encountered.The team led by John Spaulding in the main mechanical shop did an excellent work, delivering countless pieces of exceptional quality in a

•Jan 1, 2008•0 citations

Atomic and molecular beams : the state of the art 2000

Roger Campargue

•Jan 1, 2000•125 citations
In Section 1.1 we introduced the subject of atomic and molecular beam formation by stating that a beam with a cosine distribution is obtained when the beam-forming impedance is a circular orice and that a narrow slit has also been employed to produce an improved beam. Most relevant theoretical papers use the convention of referring to ‘molecules’ for both atoms and molecules, but we continue to retain the consistent use of ‘atoms’ to mean both atoms and molecules unless a distinction is necessary. Following the introduction of the basic equations of the kinetic theory of gases in Section 2.2, the relatively simple expressions for the beam formed by an orice were introduced in Section 2.3. It was also mentioned in Section 1.1 that when the impedance is a single tube a much narrower collimated beam is obtained and that by employing an array of tubes a greatly improved beam intensity is obtained. In this chapter we present the theory of beam formation to include the more difcult case of ow through a tube. We only briey mention calculations that only apply when Γ ≤ 10 where Γ is the ratio of length l to diameter d (Section 2.5). These are of little interest for atomic beam formation, but are needed for calculations of Knudsen cell operation, which are outside the scope of this work. Following the discussion of the basic theory, we present in the next chapter simplications that make the design of an atomic beam and the predictions of its performance easier. However, we warn that an extensive comparison of theoretical results with experiment in Chapter 11 points to an unsatisfactory disagreement between theory and experiment for the beam halfwidth, especially in the case of gaseous rather than vapour beams and also particularly when the beam-forming impedance is a focussing capillary array.
If a beam is to be produced from a material that is solid or liquid at laboratory temperature, then it must be converted to a vapour in an oven before it passes through the beam-forming impedance. In the reviews mentioned in Section 1.2, the approach has usually been to give details of numerous designs. In this chapter, we discuss the general design principles, and then the next two chapters become more of a reference source for the evaporation of different substances. We thus include the experience of a large number of experimenters who have needed to heat a liquid or solid substance to form it into an atomic or molecular beam. If the material can be evaporated and raised to a temperature to give the required input pressure at the input to the impedance at a temperature less than about 1500 K, it is usual to describe the heating device as an oven. At higher temperatures, the device is usually called a furnace, but the distinction is not really necessary. Hence we will avoid the term except for thermal dissociation of a molecular species, discussed in Chapter 6, when very high temperatures are usually needed, so a furnace is a more appropriate term. For convenience we will also term a completely different approach, namely, the evaporation of the material by direct electron beam heating of the surface (Section 3.2.5) as an oven. ‘Crucible’ is used by many authors interchangeably with ‘oven,’ but it often implies a container for the material to be evaporated that is placed within a heated envelope.
In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further. In the ultracold FIB project a high brightness ion beam is developed for usage in a focused ion beam (FIB) source. This Focused Ion Beam can be used in applications where milling, imaging and deposition at the nanoscale needs to be done with increasing demands on control and resolution. The generation of the ion beam done in three stage principle. The first stage is the generation of the atomic beam and this is the subject of this work. The following stages first transversely cool and compress the atomic beam by using laser cooling techniques and then ionize and accelerate the atoms to form the ion beam. The generation of the atomic beam is done using a Knudsen cell; an effusive oven containing a vapor of rubidium atoms. The pressure difference between the vapor pressure in the oven and the vacuum outside the oven generates a flow of atoms from the oven to the vacuum. Only atoms that have a low transverse velocity can be captured by the laser cooling stage and will attribute to the ion beam. Therefore it is important to minimize the divergence in the beam and to this extent a collimating tube is used to connect the effusive oven to the vacuum system. The collimating tube minimizes beam divergence and compared to other collimating mechanisms it reduces the amount of rubidium loss, therefore greatly increasing the lifetime of the system.In order to measure the transverse velocity distribution, the transverse beam profile and the total flux, Laser-Induced Fluorescence measurements have been performed. These measurements show that the source generates an atomic beam with a particle flux ranging from 107 s-1 at a source temperature of 60 ºC to 1010 s-1 at a source temperature of 160 ºC. The flux is lower than predicted by theory and the transverse velocity distribution is broader than predicted by theory. However, the particle flux is stable within 1% and the installation of an active temperature controller promises to improve this stability even further.
Currently the fields studying or using molecules with low kinetic energies are experiencing an unprecedented growth.Astronomers and chemists are interested in chemical reactions taking place at temperatures below or around 20 K, spectroscopists could make very precise measurements on slow molecules and molecular physicists could chart the potential energy surfaces more accurately.And the list continues.All of these experiments need slow molecules, with kinetic energies from around 10 cm -1 down to 0. Several designs of cold sources have already been made.The most interesting ones are presented.This work describes the design and the testing of a cold source based on the collisional cooling technique: the molecules of interest are cooled well below their freezing point by a precooled buffer gas.This way condensation is avoided.The source is a copper cell cooled to 4.2 K by an external liquid helium bath.The cell is filled with cold buffer gas (helium).The molecules of choice (ammonia) are injected through a narrow tube in the middle of the cell.The cold molecules leave the cell through a 1 millimeter hole.Two versions of pulsing techniques have been employed: a shutter blade which covers the source hole and opens it only for short moments, and a chopper that modulates the beam further downstream.Both produced pulse lengths around 1 millisecond.The source is tested in an experiment in which the emerging molecules are focused and detected.Time of flight technique is used to measure the kinetic energies.Two detectors have been employed: a microwave cavity to analyze the state of the molecules in the beam, and a mass spectrometer to measure the number density of the particles.The molecules coming out of the source hole are formed into a beam by an electrostatic quadrupole state selector.The quantum mechanical aspects and the elements of electrodynamics involved in the focusing are described.A computer simulation program is presented, which helped calculate the trajectories of the molecules from source to the final detector.The simulations revealed interesting artifacts the focuser can make: if a short state selector is used, the speed distribution of the beam arriving at the detector is strongly modulated by a "focuser transfer function".The essence of the phenomenon is caused by the inability of the focuser to focus all speed at the same time: a few velocity groups are well focused, while many others are defocused.The transfer functions gained from the simulations were used to correctly interpret the detector signal.iii The design of the microwave cavity (Fabry-Perot) and its driving electronics is presented.Due to unavoidable noises present in the circuit, the use of this detector was limited to the preliminary experiments.A simple, commercial mass spectrometer was used.To improve its characteristics, a few modifications have been made.With the improved version, only the water background (an interfering signal at mass 17 amu) was disturbing the signal.A liquid nitrogen trap has been used to minimize the background.The experimental measurements revealed several undesired effects accompanying the production of the slow beam: cluster formation, snow accumulation inside the cell and very high sensitivity to the balance of the two gas pressures.Clusters made up the majority of the emitted particles.Switching from the shutter-blade pulsing (closed cell) to the chopper modulation (open cell) improved the ratio of the useful molecules in the beam significantly.The snow accumulation limited the useful experimenting time to around 20 minutes.After this the accumulated ammonia snow either perturbed the signal significantly or obstructed the source hole completely.A very high sensitivity to the ratio of the buffer gas pressure to the ammonia injection rate has been noticed.A 30% deviation from the optimum value can change the speed distribution and the amount of emitted molecules completely.The stabilization of the ballast pressures was necessary.The beam obtained in the optimal regime of the source cell is presented and analyzed.The characteristic values of most interest in a future collision experiment are the following: the speed distribution of the beam at the detector has a height of the order of 10 5 molecules per unit speed interval and per pulse; the useful speed interval is from 55 m/s to 500 m/s.iv Dedicated to my wife, Magdi.v ACKNOWLEDGMENTS According to an East European folktale a king wanted to find out how much his daughters loved him.When the smallest princess answered "I love you like salt", the angry king banished her from the kingdom.It was only later, when the kingdom was totally deprived of salt, that he realized the real value of his daughter's words.I believe it was the salt of science that I received from my advisor, Frank De Lucia.His endless optimism always kept me going forward and taught me how to deal with difficulties now and in the future.He always made himself available, and never let me go without an excellent idea or a piece of advice.An exceptional scientist and a wonderful man, he will always be the distant example to follow in my scientific career.Gregory Lafyatis also deserves my gratitude for his insights into many of the theoretical aspects of my research.The instruments he lent me made my work in the lab much easier.I also thank Joe Demers for helping me in the lab at the most difficult time: the beginning.I am very thankful to my colleagues, Ivan Medvedev and David Graff for being always interested in my work and giving me valuable ideas.I am especially grateful to Christopher Neese for helping me with LabView related problems at a crucial moment of my research.I wish to thank Kent Ludwig for his tedious work on the low-temperature components of the experimental setup.Tom Kelch, advisor in the student mechanical shop, always had the right solution to the mechanical engineering problems I encountered.The team led by John Spaulding in the main mechanical shop did an excellent work, delivering countless pieces of exceptional quality in a