CONSIDERATIONS AFFECTING THE DESIGN OF ATOMIC - AND MOLECULAR-BEAM APPARATUS

Douglas W. McColm

Published May 17, 1965• 0 citations
OpenAlex

Related papers

ADVANCES IN ATOMIC, MOLECULAR, AND OPTICAL PHYSICS PREFACE

G. S. Agarwal, Wolfgang P. Schleich, Gerhard Rempe +1 more

Advances in atomic, molecular, and optical physics•Jan 1, 2006•0 citations

PRELIMINARY RESEARCH ON A MOLECULAR BEAM FOR THE 1-10 ev RANGE

George T. Skinner, Charles E. Treanor

The design and construction of a molecular-beam apparatus for the production of atomic and molecular beams in the 1 to 10 ev energy range are discussed. A shock tube is used as the source of high-temperature, high-pressure gas, and a hypersonic expansion is used to obtain a high-energy, nearly mono- energetic beam. Use of a two-center potential for the treatment of atom-molecule collisions is discussed. (auth)

•Dec 1, 1959•0 citations

Atomic and Molecular Beams: The State of the Art 2000

Tosi, Paolo, Bassi, Davide

Springer eBooks•Jan 1, 2001•181 citations

Atomic and molecular beams : the state of the art 2000

Roger Campargue

•Jan 1, 2000•125 citations

Merged neutral beams

Andreas Osterwalder

A detailed description of a merged beam apparatus for the study of low energy molecular scattering is given. This review is intended to guide any scientist who plans to construct a similar experiment, and to provide some inspiration in describing the approach we chose to our goal. In our experiment a supersonic expansion of paramagnetic particles is merged with one of polar molecules. A magnetic and an electric multipole guide are used to bend the two beams onto the same axis. We here describe in detail how the apparatus is designed, characterised, and operated.

EPJ Techniques and Instrumentation•Jul 24, 2015•48 citations

SIMULTANEOUS DETECTION OF COUNTER-PROPAGATING ATOMIC BEAMS FOR USE IN AN ATOMIC GYROSCOPE

Evan K. Seto

Inertial navigation systems (INSs) are a redundant form of navigation for modern naval platforms and a primary form in Global Positioning System (GPS) denied environments. Current technologies like ring laser gyroscopes (RLG) are used by INSs to measure rotation and acceleration. These measurements are then used to determine position via dead reckoning. There are, however, limitations to the accuracy and stability of this technology. The fundamental sensitivity of an RLG is determined by the effective mass of the photon, which is very small. RLGs are also prone to measurement drift, leading to errors that compound over time. Atomic interferometers show increases in both accuracy and stability over time. Atomic interferometer measurements are fundamentally tied to the mass of an atom, which is ten orders of magnitude larger than the photon’s effective mass. These systems have significantly reduced measurement drift because atomic parameters, which can be tied to gyroscope parameters like scale factors, do not change over time. We discuss the complications of using atomic interferometers as gyroscopes. Two area-reversed interferometers are needed for an atomic gyroscope to distinguish between rotation and acceleration. We explore the addition of a second atomic beam to form a second interferometer in the NPS apparatus. Both atomic beams are characterized separately to verify optimal apparatus settings before a laser is used to simultaneously detect counter-propagating beams.

•Sep 1, 2025•0 citations
A detailed description of a merged beam apparatus for the study of low energy molecular scattering is given. This review is intended to guide any scientist who plans to construct a similar experiment, and to provide some inspiration in describing the approach we chose to our goal. In our experiment a supersonic expansion of paramagnetic particles is merged with one of polar molecules. A magnetic and an electric multipole guide are used to bend the two beams onto the same axis. We here describe in detail how the apparatus is designed, characterised, and operated.
Inertial navigation systems (INSs) are a redundant form of navigation for modern naval platforms and a primary form in Global Positioning System (GPS) denied environments. Current technologies like ring laser gyroscopes (RLG) are used by INSs to measure rotation and acceleration. These measurements are then used to determine position via dead reckoning. There are, however, limitations to the accuracy and stability of this technology. The fundamental sensitivity of an RLG is determined by the effective mass of the photon, which is very small. RLGs are also prone to measurement drift, leading to errors that compound over time. Atomic interferometers show increases in both accuracy and stability over time. Atomic interferometer measurements are fundamentally tied to the mass of an atom, which is ten orders of magnitude larger than the photon’s effective mass. These systems have significantly reduced measurement drift because atomic parameters, which can be tied to gyroscope parameters like scale factors, do not change over time. We discuss the complications of using atomic interferometers as gyroscopes. Two area-reversed interferometers are needed for an atomic gyroscope to distinguish between rotation and acceleration. We explore the addition of a second atomic beam to form a second interferometer in the NPS apparatus. Both atomic beams are characterized separately to verify optimal apparatus settings before a laser is used to simultaneously detect counter-propagating beams.