AIAA SciTech Forum

Slow Light Imaging Spectroscopy (SLIS): A Simulation of Broad Linewidth Signals

Amirhossein Abbasszadehrad, Anuj Rekhy, Arthur Dogariu, Richard B. Miles

Published Jan 3, 2022• 3 citations
Publisher

Abstract

View Video Presentation: https://doi.org/10.2514/6.2022-1747.vid In this study, we calculate the delayed output of light passing an atomic vapor cell where the input signal is relatively broad. We use a deconvolution/convolution method to decompose a signal into Gaussian portions. We calculate the outputs of these portions and add them together to find the output signal. Results show that a mercury cell with a longer path length operating at a lower temperature performs better due to reduced pressure broadening.

DOI
10.2514/6.2022-1747

Related papers

Slow Light Imaging Spectroscopy (SLIS): A Comparison of Different Filters

Amirhossein Abbasszadeh Rad, Anuj Rekhy, Arthur Dogariu +1 more

In this study, we model four atomic filters useful in slow light imaging spectroscopy. We calculate delay using the group velocity in rubidium at 780 nm, mercury at 254 nm, and cesium at 852 nm and 387.6 nm at different temperatures and path lengths of the atomic filter. We also calculate the output of a 5 ns pulse by propagating its Fourier components through cells. Then we compare the results of these two numerical models with the ideal limit set only by the natural linewidth of the atomic transition. This ideal limit corresponds to cases where the frequency is right between two equally strong absorption lines. In this case, delay and transmittance are as high as possible. By tuning the frequency to peaks of transmittance, the filter can work close to ideal. Cesium cell at 387.6, though unable to reach the ideal limit at normal temperatures and path lengths, can still separate this frequency at the cost of less than ideal transmittance.

AIAA AVIATION Forum•Jun 8, 2020•7 citations

Seeded Optical Parametric Oscillator as a Light Source for Slow-Light Imaging Spectroscopy

Boris S. Leonov, Robert T. Randolph, Anuj Rekhy +5 more

View Video Presentation: https://doi.org/10.2514/6.2023-1861.vid In this article, the authors discuss an experimental demonstration of a seeded Optical Parametric Oscillator as a light source for Slow Light Imaging Spectroscopy applications. An advantage of such a system, namely narrow linewidth of less than 400 MHz, allows for precise profiling of slow light features of atomic rubidium vapor, produced by high refractive index gradients in the vicinity of resonant transitions. Time delays of up to 48 ns were observed with a clear definition of the delayed pulse from the parasitic Mie and Rayleigh scattering. A comparison between the experimental data and numerical simulation over a frequency detuning range from -1 GHz to 4 GHz shows a good agreement for both qualitative and quantitative results.

AIAA SciTech Forum•Jan 19, 2023•1 citation

Slow Light Imaging Spectroscopy: Sensitivity of the Instrument Function to Optical Thickness and Gate Delay

Amirhossein Abbasszadehrad, Jason M. Meyers, Kevin A. Brown +4 more

In this study, we investigate the effect of the optical thickness of an atomic vapor cell and the delay of the gated camera on the instrument function in Slow Light Imaging Spectroscopy. In an atomic vapor medium, the slow light effect happens at certain frequency windows where there is a large slope of the index of refraction versus frequency. The extent of these windows depends on the important parameters of the vapor cell (i.e., the optical thickness). Furthermore, the gate delay determines the minimum amount of delay that a signal needs to experience before it is detected. These two parameters determine the shape of the instrument function of the spectrometer in slow light imaging spectroscopy. Simulation and experimental results show that when absorption lines of cesium vapor at 852.1 nm are used as a delay medium, the instrument function at low temperature consists of four peaks corresponding to the steep refractive index gradients at either side of the two hyperfine absorption lines. By increasing the temperature, these peaks move away from the absorption lines. When the two peaks between the two absorption lines move away from their corresponding absorption lines, they move closer to each other until they blend, forming a strong peak. By increasing the gate delay, the four peaks of the instrument function reappear.

AIAA SciTech Forum•Jan 4, 2024•1 citation

Experimental Demonstration of Dispersion of Rayleigh Brillouin Scattering from Air with an Atomic Cesium Vapor Prism Cell

Anuj Rekhy, Boris S. Leonov, Amirhossein Abbasszadehrad +4 more

View Video Presentation: https://doi.org/10.2514/6.2022-3365.vid In this work, we demonstrate a new high throughput, high resolution spectroscopic technique based on dispersion in cesium atomic vapor and use it to image the Rayleigh-Brillouin spectrum from air. This is accomplished by utilizing a prism shaped cesium vapor cell and taking advantage of the steep refractive index in the vicinity of atomic resonances of the cesium D2 hyperfine lines at 852.113 nm. A laser beam from a tunable, continuous, and narrow linewidth Ti:sapphire laser was focused in ambient air and the spectrally dispersed scattering was imaged onto a camera after passing through a 80 mm long cesium prism vapor cell. The strong dispersion enables the measurement of the characteristic thermal and acoustic broadening of the Rayleigh-Brillouin scattering. Mie scattering from particles in the air is also captured and can be separated from molecular Rayleigh-Brillouin scattering by tuning close to the cesium resonance. The trade-off between spectral resolution by dispersion and loss of signal by cesium absorption is analyzed by tuning the laser. This technique shows the feasibility to measure the thermodynamic properties of a gas by reconstruction of the Rayleigh-Brillouin spectrum and could be applicable for advanced LIDAR measurements of atmospheric properties.

AIAA AVIATION Forum•Jun 20, 2022•2 citations

The Delayed Images in a Hot Rubidium Atomic Vapor

Long Sui

We report an experimental realization of the delayed images in a hot rubidium atomic vapor. With a rubidium atomic vapor cell as slow light medium, the image quality of the experiment could be improved greatly, compared with the results without a slow light medium. By analyzing the results about the image visibility of the slow light imaging system under three different conditions, the image visibility becomes better with the increment of the temperature, during the time that the wavelength of the laser is within dispersion range.

World Journal of Engineering and Technology•Jan 1, 2015•0 citations

Slow Light Imaging Spectroscopy

Richard B. Miles, Arthur Dogariu

Slow Light Imaging Spectroscopy has the potential to provide high spectral resolution while preserving an imaging capability for Rayleigh, Raman and Thomson scattering. This paper examines the extinction ratio and optimum time delay associated with a rubidium vapor cell and Rayleigh/Mie scattering at 780nm. Extinction ratios of better than 1000 are measured, and it is expected that much greater extinction can be achieved with better optimized laser systems.

AIAA SciTech Forum•Jan 5, 2020•5 citations
View Video Presentation: https://doi.org/10.2514/6.2022-1747.vid In this study, we calculate the delayed output of light passing an atomic vapor cell where the input signal is relatively broad. We use a deconvolution/convolution method to decompose a signal into Gaussian portions. We calculate the outputs of these portions and add them together to find the output signal. Results show that a mercury cell with a longer path length operating at a lower temperature performs better due to reduced pressure broadening.
In this study, we model four atomic filters useful in slow light imaging spectroscopy. We calculate delay using the group velocity in rubidium at 780 nm, mercury at 254 nm, and cesium at 852 nm and 387.6 nm at different temperatures and path lengths of the atomic filter. We also calculate the output of a 5 ns pulse by propagating its Fourier components through cells. Then we compare the results of these two numerical models with the ideal limit set only by the natural linewidth of the atomic transition. This ideal limit corresponds to cases where the frequency is right between two equally strong absorption lines. In this case, delay and transmittance are as high as possible. By tuning the frequency to peaks of transmittance, the filter can work close to ideal. Cesium cell at 387.6, though unable to reach the ideal limit at normal temperatures and path lengths, can still separate this frequency at the cost of less than ideal transmittance.
View Video Presentation: https://doi.org/10.2514/6.2023-1861.vid In this article, the authors discuss an experimental demonstration of a seeded Optical Parametric Oscillator as a light source for Slow Light Imaging Spectroscopy applications. An advantage of such a system, namely narrow linewidth of less than 400 MHz, allows for precise profiling of slow light features of atomic rubidium vapor, produced by high refractive index gradients in the vicinity of resonant transitions. Time delays of up to 48 ns were observed with a clear definition of the delayed pulse from the parasitic Mie and Rayleigh scattering. A comparison between the experimental data and numerical simulation over a frequency detuning range from -1 GHz to 4 GHz shows a good agreement for both qualitative and quantitative results.
In this study, we investigate the effect of the optical thickness of an atomic vapor cell and the delay of the gated camera on the instrument function in Slow Light Imaging Spectroscopy. In an atomic vapor medium, the slow light effect happens at certain frequency windows where there is a large slope of the index of refraction versus frequency. The extent of these windows depends on the important parameters of the vapor cell (i.e., the optical thickness). Furthermore, the gate delay determines the minimum amount of delay that a signal needs to experience before it is detected. These two parameters determine the shape of the instrument function of the spectrometer in slow light imaging spectroscopy. Simulation and experimental results show that when absorption lines of cesium vapor at 852.1 nm are used as a delay medium, the instrument function at low temperature consists of four peaks corresponding to the steep refractive index gradients at either side of the two hyperfine absorption lines. By increasing the temperature, these peaks move away from the absorption lines. When the two peaks between the two absorption lines move away from their corresponding absorption lines, they move closer to each other until they blend, forming a strong peak. By increasing the gate delay, the four peaks of the instrument function reappear.
View Video Presentation: https://doi.org/10.2514/6.2022-3365.vid In this work, we demonstrate a new high throughput, high resolution spectroscopic technique based on dispersion in cesium atomic vapor and use it to image the Rayleigh-Brillouin spectrum from air. This is accomplished by utilizing a prism shaped cesium vapor cell and taking advantage of the steep refractive index in the vicinity of atomic resonances of the cesium D2 hyperfine lines at 852.113 nm. A laser beam from a tunable, continuous, and narrow linewidth Ti:sapphire laser was focused in ambient air and the spectrally dispersed scattering was imaged onto a camera after passing through a 80 mm long cesium prism vapor cell. The strong dispersion enables the measurement of the characteristic thermal and acoustic broadening of the Rayleigh-Brillouin scattering. Mie scattering from particles in the air is also captured and can be separated from molecular Rayleigh-Brillouin scattering by tuning close to the cesium resonance. The trade-off between spectral resolution by dispersion and loss of signal by cesium absorption is analyzed by tuning the laser. This technique shows the feasibility to measure the thermodynamic properties of a gas by reconstruction of the Rayleigh-Brillouin spectrum and could be applicable for advanced LIDAR measurements of atmospheric properties.
We report an experimental realization of the delayed images in a hot rubidium atomic vapor. With a rubidium atomic vapor cell as slow light medium, the image quality of the experiment could be improved greatly, compared with the results without a slow light medium. By analyzing the results about the image visibility of the slow light imaging system under three different conditions, the image visibility becomes better with the increment of the temperature, during the time that the wavelength of the laser is within dispersion range.