Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)

Towards a Continuous Active Optical Atomic Clock With Cold Strontium Atoms

Marcin Bober, Sławomir Bilicki, Anahit L. Gogyan, Domagoj Kovačić, Piotr Morzyński, Mateusz Narożnik, A. Tonoyan, V. Singh, Marcin Witkowski, M. Zawada

Published Jul 7, 2021• 0 citations
Publisher

Abstract

We present a setup designed for an active optical atomic clock operating at the clock transition (1S0-3P0) with cold strontium atoms. The apparatus is designed for continuous operation, and it is designed for both 87Sr and 88Sr isotopes.
DOI
10.1109/eftf/ifcs52194.2021.9604263

Related papers

Strontium Optical Atomic Clocks in KL FAMO Blue Detuned Lattice for Strontium Atoms and Project of a Continuous Active Optical Clock with Cold Strontium Atoms

Marcin Bober, Piotr Ablewski, Sławomir Bilicki +10 more

We would like to report on a design of new type of optical atomic clock - a continuous active clock with cold strontium atoms, as well as on progress with lattice clocks in KL FAMO. The active clock design will use blue detuned optical lattice to provide the Lamb-Dicke regime in the optical cavity, where conditions for superradiance emission on the clock transition will be meet. Studies of the blue detuned magic wavelength for88Sr will be presented together with possibility to create a state dependence, blue detuned optical lattice.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Apr 1, 2019•0 citations

Design considerations for a 87Sr optical clock at VNIIFTRI

S. Sluysarev, A S Kostin, V. N. Baryshev +2 more

We report on progress made at the VNIIFTRI towards a87Sr optical clock. A detailed description of the main parts of the apparatus is given together with the preliminary measurements characterizing step by step the cooling and trapping of the strontium atoms. The Sr-MOT is operative and the first observation the cloud of cold atoms in the blue MOT is reported.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•May 1, 2011•0 citations

Precision spectroscopy of cold strontium atoms, towards optical atomic clock

Marcin Bober, Jerzy Zachorowski, Wojciech Gawlik +10 more

Abstract This report concerns the experiment of precision spectroscopy of cold strontium atoms in the Polish National Laboratory of Atomic, Molecular and Optical Physics in Toruń. The system is composed of a Zeeman slower and magneto-optical traps (at 461 nm and 689 nm), a frequency comb, and a narrow-band laser locked to an ultra-stable optical cavity. All parts of the experiment are prepared and the first measurements of the absolute frequency of the 1S0-3P1, 689 nm optical transition in 88Sr atoms are performed.

Bulletin of the Polish Academy of Sciences Technical Sciences•Dec 1, 2012•6 citations

Frequency Measurements of Superradiance from the Strontium Clock Transition

Matthew A. Norcia, Julia R. K. Cline, Juan A. Muniz +6 more

The frequency stability of superradiant light emitted from an optical clock transition in cold strontium atoms surpasses that of active microwave atomic clocks, paving the way for a next generation of high-precision optical frequency references to be used outside the laboratory environment.

arXiv:1711.10407•Physical Review X•May 9, 2018•131 citations

Open-source electronics ecosystem for optical atomic clocks

Piotr Morzyński, Sławomir Bilicki, Marcin Bober +4 more

Abstract We present an open-source hardware and software ecosystem for optical atomic clocks. We provide PCB schematics and fabrication files for manufacturing the most important electronic systems together with the required software. The boards are designed for an active bad-cavity superradiant strontium clock and a passive optical lattice strontium clock, but they can be easily adapted to other atomic species’ optical atomic clocks or ultra-cold atoms’ systems like magneto-optical traps or Bose–Einstein condensate setups.

Measurement Science and Technology•Mar 20, 2023•2 citations

ISOTOPE SHIFT SPECTROSCOPY OF ULTRACOLD STRONTIUM

Neal C. Pisenti

We describe the design, construction, and performance of a laser system to probe the ultra-narrow (Γ/2π ≈ mHz) clock transition 1S0 → 3P0 in strontium. We present the first reported spectroscopy of this transition in two of the bosonic isotopes, 84Sr and 86Sr. Furthermore, we measure the complete set of isotope shifts between all four stable isotopes on the clock line and the narrow intercombination line 1S0 → 3P1, permitting a King plot analysis of the isotope shifts. Complications arising from the unambiguous determination of a line center in 87Sr 3P1 prevent us from making claims about the King linearity, but we provide a statistical boot- strap analysis of the isotope shifts 88−84Sr and 88−86Sr to compute a field shift ratio F698/F689 = 0.9979, with a 95% confidence interval [0.9952,1.0008]. The intercept term K698 − (F698/F689) K689 is similarly determined to be -2.0 GHz-amu, with a 95% confidence interval [−3.9, −0.3] GHz-amu. Finally, we describe the design of a next-generation apparatus that will enable improvements on the results described here, as well as other studies that involve coherent manipulation of strontium atoms on the clock line.

•Jan 1, 2019•1 citation
We would like to report on a design of new type of optical atomic clock - a continuous active clock with cold strontium atoms, as well as on progress with lattice clocks in KL FAMO. The active clock design will use blue detuned optical lattice to provide the Lamb-Dicke regime in the optical cavity, where conditions for superradiance emission on the clock transition will be meet. Studies of the blue detuned magic wavelength for88Sr will be presented together with possibility to create a state dependence, blue detuned optical lattice.
Abstract This report concerns the experiment of precision spectroscopy of cold strontium atoms in the Polish National Laboratory of Atomic, Molecular and Optical Physics in Toruń. The system is composed of a Zeeman slower and magneto-optical traps (at 461 nm and 689 nm), a frequency comb, and a narrow-band laser locked to an ultra-stable optical cavity. All parts of the experiment are prepared and the first measurements of the absolute frequency of the 1S0-3P1, 689 nm optical transition in 88Sr atoms are performed.
Abstract We present an open-source hardware and software ecosystem for optical atomic clocks. We provide PCB schematics and fabrication files for manufacturing the most important electronic systems together with the required software. The boards are designed for an active bad-cavity superradiant strontium clock and a passive optical lattice strontium clock, but they can be easily adapted to other atomic species’ optical atomic clocks or ultra-cold atoms’ systems like magneto-optical traps or Bose–Einstein condensate setups.
We describe the design, construction, and performance of a laser system to probe the ultra-narrow (Γ/2π ≈ mHz) clock transition 1S0 → 3P0 in strontium. We present the first reported spectroscopy of this transition in two of the bosonic isotopes, 84Sr and 86Sr. Furthermore, we measure the complete set of isotope shifts between all four stable isotopes on the clock line and the narrow intercombination line 1S0 → 3P1, permitting a King plot analysis of the isotope shifts. Complications arising from the unambiguous determination of a line center in 87Sr 3P1 prevent us from making claims about the King linearity, but we provide a statistical boot- strap analysis of the isotope shifts 88−84Sr and 88−86Sr to compute a field shift ratio F698/F689 = 0.9979, with a 95% confidence interval [0.9952,1.0008]. The intercept term K698 − (F698/F689) K689 is similarly determined to be -2.0 GHz-amu, with a 95% confidence interval [−3.9, −0.3] GHz-amu. Finally, we describe the design of a next-generation apparatus that will enable improvements on the results described here, as well as other studies that involve coherent manipulation of strontium atoms on the clock line.