Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Log inSign up
Challenges
Datasets
Workspaces
Papers
Discussions
Leaderboard
Blog
Job Board
Q3AS

© 2026 Aqora Quantum S.A.S.

TermsPrivacyLegal Notice

arXiv:1711.10407 · Physical Review X

Frequency Measurements of Superradiance from the Strontium Clock Transition

Matthew A. Norcia, Julia R. K. Cline, Juan A. Muniz, John M. Robinson, Ross B. Hutson, Akihisa Goban, G. Edward Marti, Jun Ye, James K. Thompson

Published May 9, 2018• 131 citations
arXivHTMLPDF

Abstract

The frequency stability of superradiant light emitted from an optical clock transition in cold strontium atoms surpasses that of active microwave atomic clocks, paving the way for a next generation of high-precision optical frequency references to be used outside the laboratory environment.
DOI
10.1103/physrevx.8.021036

Related papers

An active optical frequency reference using a pulsed superradiant laser

Juan Muniz Silva, Julia Cline, James K. Thompson +1 more

We will describe a next-generation active atomic frequency reference based on super-radiant pulses of laser light from the ultra-narrow, 1 mHz linewidth, optical clock transition in an ensemble of cold 87Sr atoms. Light is stimulated from the millihertz linewidth transition by confining an ensemble of laser cooled atoms inside of a high finesse optical cavity. Such a light source has been proposed as a next-generation active atomic frequency reference, with the potential to enable high-precision optical frequency references to be used outside laboratory environments. We achieve a remarkable short term fractional frequency stability, 6.7 × 1016 at 1 s of averaging, absolute accuracy, 2 Hz (4 × 1015 fractional frequency), and high insensitivity to changes in the cavity length that limits the performance of todays more stable lasers. We will also discuss current work on cavity-enhanced dispersive measurements to perform high resolution spectroscopy and atom counting.

Optical and Quantum Sensing and Precision Metrology II•Mar 1, 2019•4 citations

Superradiant active optical atomic clocks: motivations and current challenges

Martina Matusko, Marion Delehaye

Abstract Current state-of-the-art frequency standards are passive optical atomic clocks where the frequency of an optical resonator is stabilized to a narrow atomic transition. Passive clocks have achieved unprecedented stabilities of 6.6 × 10−19 over one hour of averaging time [1]. However, they face intrinsic limitations, particularly due to thermal and mechanical fluctuations of the local oscillator. To surpass the limitations of the passive clocks and go beyond the state-of-the-art, the idea of building active optical atomic clocks emerges. These clocks would be optical counterparts of hydrogen masers, with the emitted frequency defined by the atomic transition and therefore inherently stable against cavity instabilities. This paper discusses the latest developments and future prospects in the field of active optical atomic clocks.

arXiv:2411.03760•Journal of Physics Conference Series•Nov 1, 2024•1 citation

Frequency stability of pulsed superradiant light from the strontium clock transition

Juan A. Muniz, Matthew A. Norcia, Julia Cline +6 more

Bulletin of the American Physical Society•May 30, 2018•0 citations

Active Frequency Measurement on Superradiant Strontium Clock Transitions

Yuan Zhang, Chongxin Shan, Klaus Mølmer

We develop a stochastic mean-field theory to describe active frequency measurements of pulsed superradiant emission, studied in a recent experiment with strontium-87 atoms trapped in an optical lattice inside an optical cavity [M. Norcia et al., Phys. Rev. X 8, 021036 (2018)PRXHAE2160-330810.1103/PhysRevX.8.021036]. Our theory reveals the intriguing dynamics of atomic ensembles with multiple transition frequencies, and it reproduces the superradiant beats signal, noisy power spectra, and frequency uncertainty in remarkable agreement with the experiments. Moreover, using longer superradiant pulses of similar strength and shortening the experimental duty cycle, we predict a short-term frequency uncertainty 7×10^{-17}/sqrt[τ/s], which makes active frequency measurements with superradiant transitions comparable with the record performance of current frequency standards [M. Schioppo et al., Nat. Photonics 11, 48 (2017)NPAHBY1749-488510.1038/nphoton.2016.231]. Our theory combines cavity quantum electrodynamics and quantum measurement theory, and it can be readily applied to explore conditional quantum dynamics and describe frequency measurements for other processes such as steady-state superradiance and superradiant Raman lasing.

arXiv:2105.12673•Physical Review Letters•Jan 7, 2022•15 citations

Towards a Continuous Active Optical Atomic Clock With Cold Strontium Atoms

Marcin Bober, Sławomir Bilicki, Anahit L. Gogyan +7 more

We present a setup designed for an active optical atomic clock operating at the clock transition (1S0-3P0) with cold strontium atoms. The apparatus is designed for continuous operation, and it is designed for both 87Sr and 88Sr isotopes.

Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS)•Jul 7, 2021•0 citations

Optical atomic phase reference and timing

Leo W. Hollberg, E H Cornell, A Abdelrahmann

Atomic clocks based on laser-cooled atoms have made tremendous advances in both accuracy and stability. However, advanced clocks have not found their way into widespread use because there has been little need for such high performance in real-world/commercial applications. The drive in the commercial world favours smaller, lower-power, more robust compact atomic clocks that function well in real-world non-laboratory environments. Although the high-performance atomic frequency references are useful to test Einstein's special relativity more precisely, there are not compelling scientific arguments to expect a breakdown in special relativity. On the other hand, the dynamics of gravity, evidenced by the recent spectacular results in experimental detection of gravity waves by the LIGO Scientific Collaboration, shows dramatically that there is new physics to be seen and understood in space–time science. Those systems require strain measurements at less than or equal to 10 −20 . As we discuss here, cold atom optical frequency references are still many orders of magnitude away from the frequency stability that should be achievable with narrow-linewidth quantum transitions and large numbers of very cold atoms, and they may be able to achieve levels of phase stability, Δ Φ / Φ total ≤ 10 −20 , that could make an important impact in gravity wave science. This article is part of the themed issue ‘Quantum technology for the 21st century’.

Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences•Jun 26, 2017•7 citations
We will describe a next-generation active atomic frequency reference based on super-radiant pulses of laser light from the ultra-narrow, 1 mHz linewidth, optical clock transition in an ensemble of cold 87Sr atoms. Light is stimulated from the millihertz linewidth transition by confining an ensemble of laser cooled atoms inside of a high finesse optical cavity. Such a light source has been proposed as a next-generation active atomic frequency reference, with the potential to enable high-precision optical frequency references to be used outside laboratory environments. We achieve a remarkable short term fractional frequency stability, 6.7 × 1016 at 1 s of averaging, absolute accuracy, 2 Hz (4 × 1015 fractional frequency), and high insensitivity to changes in the cavity length that limits the performance of todays more stable lasers. We will also discuss current work on cavity-enhanced dispersive measurements to perform high resolution spectroscopy and atom counting.
Abstract Current state-of-the-art frequency standards are passive optical atomic clocks where the frequency of an optical resonator is stabilized to a narrow atomic transition. Passive clocks have achieved unprecedented stabilities of 6.6 × 10−19 over one hour of averaging time [1]. However, they face intrinsic limitations, particularly due to thermal and mechanical fluctuations of the local oscillator. To surpass the limitations of the passive clocks and go beyond the state-of-the-art, the idea of building active optical atomic clocks emerges. These clocks would be optical counterparts of hydrogen masers, with the emitted frequency defined by the atomic transition and therefore inherently stable against cavity instabilities. This paper discusses the latest developments and future prospects in the field of active optical atomic clocks.
We develop a stochastic mean-field theory to describe active frequency measurements of pulsed superradiant emission, studied in a recent experiment with strontium-87 atoms trapped in an optical lattice inside an optical cavity [M. Norcia et al., Phys. Rev. X 8, 021036 (2018)PRXHAE2160-330810.1103/PhysRevX.8.021036]. Our theory reveals the intriguing dynamics of atomic ensembles with multiple transition frequencies, and it reproduces the superradiant beats signal, noisy power spectra, and frequency uncertainty in remarkable agreement with the experiments. Moreover, using longer superradiant pulses of similar strength and shortening the experimental duty cycle, we predict a short-term frequency uncertainty 7×10^{-17}/sqrt[τ/s], which makes active frequency measurements with superradiant transitions comparable with the record performance of current frequency standards [M. Schioppo et al., Nat. Photonics 11, 48 (2017)NPAHBY1749-488510.1038/nphoton.2016.231]. Our theory combines cavity quantum electrodynamics and quantum measurement theory, and it can be readily applied to explore conditional quantum dynamics and describe frequency measurements for other processes such as steady-state superradiance and superradiant Raman lasing.
Atomic clocks based on laser-cooled atoms have made tremendous advances in both accuracy and stability. However, advanced clocks have not found their way into widespread use because there has been little need for such high performance in real-world/commercial applications. The drive in the commercial world favours smaller, lower-power, more robust compact atomic clocks that function well in real-world non-laboratory environments. Although the high-performance atomic frequency references are useful to test Einstein's special relativity more precisely, there are not compelling scientific arguments to expect a breakdown in special relativity. On the other hand, the dynamics of gravity, evidenced by the recent spectacular results in experimental detection of gravity waves by the LIGO Scientific Collaboration, shows dramatically that there is new physics to be seen and understood in space–time science. Those systems require strain measurements at less than or equal to 10 −20 . As we discuss here, cold atom optical frequency references are still many orders of magnitude away from the frequency stability that should be achievable with narrow-linewidth quantum transitions and large numbers of very cold atoms, and they may be able to achieve levels of phase stability, Δ Φ / Φ total ≤ 10 −20 , that could make an important impact in gravity wave science. This article is part of the themed issue ‘Quantum technology for the 21st century’.