The primary frequency and time standard, defined via a transition frequency of caesium-133, is realized by microwave clocks reaching relative uncertainties in the 10−^16 level. This performance has been surpassed by state-of-the-art lattice clocks, with transition frequencies in the optical regime, leading to two orders of magnitude lower uncertainties. The key to this performance is the confinement in the Lamb-Dicke regime at the magic wavelength enabling a Doppler- and recoil-free spectroscopy with a first-order suppressed AC Stark shift. In atomic clocks, several effects contribute to the uncertainty of the transition frequency. Through continuous global characterization efforts, the individual uncertainty of these effects have been subsequently reduced. Yet one effect, namely the frequency shift induced by blackbody radiation has been identified as a dominant contribution which is difficult to overcome by technical means. In this regard, magnesium-24 excels as a species of choice as its blackbody radiation sensitivity is one order of magnitude lower than in the most frequently used atomic clock species. Furthermore, magnesium offers a relatively simple electronic structure which enables theoretical support through high-precision calculations. This thesis features the first characterization of a magnesium optical lattice clock operating at the magic wavelength. The characterization of the magnesium frequency standard presented in this thesis depends essentially on the resolution of the transition linewidth, which could be reduced from kHz range to 51(3) Hz in a complementing work. The realization of a transition linewidth with a quality factor of Q = 1.3 × 10^13 has contributed to an improved determination of the magic wavelength within this thesis to 468.4106(2) nm. Compared to earlier work, this represents an improvement of two orders of magnitude. Furthermore, the lower transition linewidth also allowed the first observation of the probe AC Stark shift and thus the first characterization of effects in the lattice that falsify the frequency of the trapped magnesium atoms. Overall, the relative uncertainty of the frequency-related effects influencing the clock transition could be determined to be 7.1 × 10^−15. The dominant contributions can be assigned to tunneling broadening and the lattice and probe AC Stark effects, induced by the probe and lattice light. All these effects can be traced back to technical limitations and are part of future work. Following the characterization, a first frequency comparison between the magnesium lattice clock against the primary frequency standard as well as the ytterbium ion clock at the PTB has been performed and thus a first realization of a lattice based frequency standard with magnesium atoms was demonstrated. The determined transition frequency of 655 058 646 681 864.1(5.3) Hz complies with former measurements. The primary frequency and time standard, defined via a transition frequency of caesium-133, is realized by microwave clocks reaching relative uncertainties in the 10^−16 level. This performance has been surpassed by state-of-the-art lattice clocks, with transition frequencies in the optical regime, leading to two orders of magnitude lower uncertainties. The key to this performance is the confinement in the Lamb-Dicke regime at the magic wavelength enabling a Doppler- and recoil-free spectroscopy with a first-order suppressed AC Stark shift. In atomic clocks, several effects contribute to the uncertainty of the transition frequency. Through continuous global characterization efforts, the individual uncertainty of these effects have been subsequently reduced. Yet one effect, namely the frequency shift induced by blackbody radiation has been identified as a dominant contribution which is difficult to overcome by technical means. In this regard, magnesium-24 excels as a species of choice as its blackbody radiation sensitivity is one order of magnitude lower than in the most frequently used atomic clock species. Furthermore, magnesium offers a relatively simple electronic structure which enables theoretical support through high-precision calculations. This thesis features the first characterization of a magnesium optical lattice clock operating at the magic wavelength. The characterization of the magnesium frequency standard presented in this thesis depends essentially on the resolution of the transition linewidth, which could be reduced from kHz range to 51(3) Hz in a complementing work. The realization of a transition linewidth with a quality factor of Q = 1.3 × 10^13 has contributed to an improved determination of the magic wavelength within this thesis to 468.4106(2) nm. Compared to earlier work, this represents an improvement of two orders of magnitude. Furthermore, the lower transition linewidth also allowed the first observation of the probe AC Stark shift and thus the first characterization of effects in the lattice that falsify the frequency of the trapped magnesium atoms. Overall, the relative uncertainty of the frequency-related effects influencing the clock transition could be determined to be 7.1 × 10^−15. The dominant contributions can be assigned to tunneling broadening and the lattice and probe AC Stark effects, induced by the probe and lattice light. All these effects can be traced back to technical limitations and are part of future work. Following the characterization, a first frequency comparison between the magnesium lattice clock against the primary frequency standard as well as the ytterbium ion clock at the PTB has been performed and thus a first realization of a lattice based frequency standard with magnesium atoms was demonstrated. The determined transition frequency of 655 058 646 681 864.1(5.3) Hz complies with former measurements.
The primary frequency and time standard, defined via a transition frequency of caesium-133, is realized by microwave clocks reaching relative uncertainties in the 10−^16 level. This performance has been surpassed by state-of-the-art lattice clocks, with transition frequencies in the optical regime, leading to two orders of magnitude lower uncertainties. The key to this performance is the confinement in the Lamb-Dicke regime at the magic wavelength enabling a Doppler- and recoil-free spectroscopy with a first-order suppressed AC Stark shift. In atomic clocks, several effects contribute to the uncertainty of the transition frequency. Through continuous global characterization efforts, the individual uncertainty of these effects have been subsequently reduced. Yet one effect, namely the frequency shift induced by blackbody radiation has been identified as a dominant contribution which is difficult to overcome by technical means. In this regard, magnesium-24 excels as a species of choice as its blackbody radiation sensitivity is one order of magnitude lower than in the most frequently used atomic clock species. Furthermore, magnesium offers a relatively simple electronic structure which enables theoretical support through high-precision calculations. This thesis features the first characterization of a magnesium optical lattice clock operating at the magic wavelength. The characterization of the magnesium frequency standard presented in this thesis depends essentially on the resolution of the transition linewidth, which could be reduced from kHz range to 51(3) Hz in a complementing work. The realization of a transition linewidth with a quality factor of Q = 1.3 × 10^13 has contributed to an improved determination of the magic wavelength within this thesis to 468.4106(2) nm. Compared to earlier work, this represents an improvement of two orders of magnitude. Furthermore, the lower transition linewidth also allowed the first observation of the probe AC Stark shift and thus the first characterization of effects in the lattice that falsify the frequency of the trapped magnesium atoms. Overall, the relative uncertainty of the frequency-related effects influencing the clock transition could be determined to be 7.1 × 10^−15. The dominant contributions can be assigned to tunneling broadening and the lattice and probe AC Stark effects, induced by the probe and lattice light. All these effects can be traced back to technical limitations and are part of future work. Following the characterization, a first frequency comparison between the magnesium lattice clock against the primary frequency standard as well as the ytterbium ion clock at the PTB has been performed and thus a first realization of a lattice based frequency standard with magnesium atoms was demonstrated. The determined transition frequency of 655 058 646 681 864.1(5.3) Hz complies with former measurements. The primary frequency and time standard, defined via a transition frequency of caesium-133, is realized by microwave clocks reaching relative uncertainties in the 10^−16 level. This performance has been surpassed by state-of-the-art lattice clocks, with transition frequencies in the optical regime, leading to two orders of magnitude lower uncertainties. The key to this performance is the confinement in the Lamb-Dicke regime at the magic wavelength enabling a Doppler- and recoil-free spectroscopy with a first-order suppressed AC Stark shift. In atomic clocks, several effects contribute to the uncertainty of the transition frequency. Through continuous global characterization efforts, the individual uncertainty of these effects have been subsequently reduced. Yet one effect, namely the frequency shift induced by blackbody radiation has been identified as a dominant contribution which is difficult to overcome by technical means. In this regard, magnesium-24 excels as a species of choice as its blackbody radiation sensitivity is one order of magnitude lower than in the most frequently used atomic clock species. Furthermore, magnesium offers a relatively simple electronic structure which enables theoretical support through high-precision calculations. This thesis features the first characterization of a magnesium optical lattice clock operating at the magic wavelength. The characterization of the magnesium frequency standard presented in this thesis depends essentially on the resolution of the transition linewidth, which could be reduced from kHz range to 51(3) Hz in a complementing work. The realization of a transition linewidth with a quality factor of Q = 1.3 × 10^13 has contributed to an improved determination of the magic wavelength within this thesis to 468.4106(2) nm. Compared to earlier work, this represents an improvement of two orders of magnitude. Furthermore, the lower transition linewidth also allowed the first observation of the probe AC Stark shift and thus the first characterization of effects in the lattice that falsify the frequency of the trapped magnesium atoms. Overall, the relative uncertainty of the frequency-related effects influencing the clock transition could be determined to be 7.1 × 10^−15. The dominant contributions can be assigned to tunneling broadening and the lattice and probe AC Stark effects, induced by the probe and lattice light. All these effects can be traced back to technical limitations and are part of future work. Following the characterization, a first frequency comparison between the magnesium lattice clock against the primary frequency standard as well as the ytterbium ion clock at the PTB has been performed and thus a first realization of a lattice based frequency standard with magnesium atoms was demonstrated. The determined transition frequency of 655 058 646 681 864.1(5.3) Hz complies with former measurements.
State-of-the-art optical clocks based on neutral atoms have already surpassed the world's best microwave atomic clocks in both accuracy and stability, paving the way to high-precision measurements of elementary aspects of nature, like the search for the drift of fundamental constants or the application of relativistic geodesy.These clocks operate with ensembles trapped in an optical lattice.Normally, high-power trapping laser fields induce a large AC Stark shift on the clock's transition frequency, as the clock states have different polarizabilities.A key feature of lattice clocks is the magic wavelength, for which the atomic polarizabilities of the clock states are equal, therefore compensating a differential frequency shift on the clock transition.In the periodic potential of the optical lattice, the energy spectrum of motional states features a band structure, analogous to electrons in a crystalline structure well-known from solid state physics.Within this band structure, atoms can tunnel between adjacent lattice sites.As a consequence from tunneling motion, the clock transition experiences a frequency shift and a broadening, which becomes pronounced in the shallow lattice regime.This work presents the first demonstration of a 24 Mg optical lattice clock including the precise determination of the frequency of the clock transition, its magic wavelength and its second-order Zeeman shift.Furthermore, the effect of tunneling in an optical lattice for magnesium has been extensively studied via optical spectroscopy of Bloch bands and substantiated with theoretical models, that were initially developed for a strontium optical lattice clock.Measuring lattice light induced frequency shifts of the clock transition for various lattice wavelengths and intensities, yielded a value of the magic wavelength of the 1 S 0 → 3 P 0 clock transition in 24 Mg of 468.463(207) nm.This value is in well agreement with a recent theoretical calculation of 468.45(23) nm, using a refined atomic structure model.The experimental value for the magic wavelength was independently verified with optical spectroscopy of Bloch bands carried out on the clock transition.Here, the AC Stark modified band structure is directly probed by a single frequency scan of the carrier resonance, featuring an asymmetric line shape, that is strongly dependent on the lattice wavelength.This technique demonstrates a novel method for the determination of the magic wavelength and could also be applied to other atomic species.In bosonic isotopes of alkaline earth(-like) elements, like 24 Mg, optical dipole excitation of the spin-forbidden 1 S 0 → 3 P 0 clock transition can be enhanced, e.g. by applying an external magnetic field.While these bosons are insensitive to first-order Zeeman shifts, the second-order Zeeman effect displays a dominant contribution to the clock's error budget.In this thesis, the magnetic polarizability β is measured to be -206.6(2.0)MHz/T 2 , consistent with a theoretical calculation, and the clock transition frequency was found to be 655 058 646 691(101) kHz.
The authors report on the recent progress in setting up a magic wavelength optical lattice for magnesium. At the magic wavelength for the1S0→3P0transition of Mg, which has been predicted to be at 463 nm, the differential AC Stark shift of the intercombination transition cancels out. Currently, the authors investigate to establish the optical lattice inside an optical resonator to enhance the trap depth and the loading of this lattice. Furthermore, the tight confinement of the atoms in the lattice will enable us to reach the Lamb-Dicke regime, allowing first order Doppler-free spectroscopy.
The measurement of time and frequency is at the heart of many technological applications and scientific measurements alike. In fact, the SI-unit the second is by quite a margin the SI-unit with the best relative uncertainty (ca. 10^{-16}), given by the accuracies of Cs fountain clocks probing the F = 3 - F = 4 ground-state transition in 133Cs. Still, demands for even higher accuracy and especially stability (a Cs fountain needs up to two weeks for the statistics to reach its declared uncertainty) are uttered in support of technological advancements (e.g. geodesy and GNSS systems) as well as fundamental science (physics beyond the standard model, tests of relativity). Nowadays optical lattice clocks confining a large number of neutral atoms in Stark shift free optical traps (the Stark shift free condition is characterised by a so-called magic wavelength of the trap) propose good candidates for a future redefinition of the SI-second in terms of an optical transition. Their accuracy and stability already surpass the Cs-fountains by two and three orders of magnitude, respectively. With further improvements to be expected in the near future, the application of optical lattice clocks to relativistic gravimetry, quantum computing, quantum simulation and fundamental physics keeps evolving. This thesis describes the development and characterisation of an 171Yb lattice clock at INRIM as well as its first frequency measurement campaigns and technolo- gies towards improved optical frequency measurements. The lattice clock confines cold atoms in a 1D optical dipole trap at the magic wavelength, which also cancels any Doppler- and recoil-related effects on the ultra-narrow clock transition. The first chapter offers a general overview of the physics behind lattice clocks and opti- cal frequency measurements. In the second chapter the 171Yb lattice clock developed during this work is expounded, including the trapping, state-preparation and state-probing of ultracold atoms inside the optical lattice. An exhaustive uncertainty budget for the clock transition is given and discussed showing already a performance beyond state-of- the-art Cs fountain clocks. An absolute frequency measurement obtained during this work is laid out. The result represents the lowest uncertainty achieved in a measurement of this transition against a primary frequency standard so far and is in agreement with previous values obtained by other groups around the world. A proof-of-principle experiment demonstrating for the first time the feasibility of transportable optical lattice clocks for geodesy and metrology applications outside of laboratory environments is described in chapter three. This experiment was conducted in collaboration with PTB and NPL and included a geodetic measurement with a transportable optical lattice clock that agreed with conventional methods as well as an optical 171Yb-87Sr frequency ratio measurement, enlarging the database on this particular ratio and thereby contributing to a possible redefinition of the SI-unit the second in terms of an optical transition or frequency-ratio matrix in the future. The fourth chapter discusses improvements added to the Yb lattice clock after the aforementioned measurements, in particular the stabilisation of the cooling and trapping lasers on a single stable low-drift cavity using mirrors coated for three disparate wavelengths across the optical spectrum. The simultaneous offset sideband locking and a throughout characterisation of the cavity are discussed. The last chapter is about the characterisation and optimisation of the NPL universal oscillator, which was conducted during my secondment at the NPL research facilities in the UK. The universal oscillator consists out of a femtosecond frequency comb, an ultra stable master laser and six slave oscillators. The femtosecond comb is transferring the stability of the superior master oscillator cavity to all six slave oscillators, which includes five lasers ranging from the infrared to the visible region. The principle of operation is explained and the obtained high performance of the spectral purity transfer set forth and discussed. This experiment demonstrated an unprecedented spectral purity transfer performance in a multi-branch configuration, opening the way for the interrogation of whole clock ensembles by just one master oscillator.
An optical lattice clock probes a spectrally narrow electronic transition in an ensemble of optically trapped, laser-cooled atoms, for use as a time and frequency standard. To date, several lattice clocks have been demonstrated with superior stability and accuracy compared to primary frequency standards based on microwave transitions. Yet, the question of which atomic system (including the element and isotope) performs best as a lattice clock remains unsettled. This thesis describes the first detailed investigation of an optical lattice clock using a spin-1/2 isotope of the ytterbium atom. A spin-1/2 system possesses several advantages over higher-spin systems, including a simplified level structure (allowing for straightforward manipulation of the nuclear spin state) and the absence of any tensor light shift from the confining optical lattice. Moreover, the ytterbium atom (Yb) stands among the leading lattice clock candidates, offering a high-performance optical clock with some degree of experimental simplicity. The frequency stability of the Yb clock is highlighted by resolving an ultra-narrow clock spectrum with a full-width at half-maximum of 1 Hz, corresponding to a record quality factor Q = ν0/Δν = 5 × 1014. Moreover, this system can be highly accurate, which is demonstrated by characterizing the Yb clock frequency at the 3 × 10-16 level of fractional uncertainty, with further progress toward a ten-fold improvement also presented. To reach this low level of uncertainty required careful consideration of important systematic errors, including the identification of the Stark-canceling wavelength, where the clock’s sensitivity to the lattice intensity is minimized, a precise determination of the static polarizability of the clock transition, and the measurement and control of atom-atom collisions.
Accurate time keeping is critical to the function and advancement of many human endeavours. Atomic clocks based on a microwave transition in atomic Cs have served as primary frequency standards to realise the SI second since their formal adoption in 1967. State-of-the-art, laser cooled, Cs fountains now routinely operate with fractional frequency uncertainties below the 10⁻¹⁵ level in laboratories throughout the world. Over the last decade, efforts to build frequency standards based on optical transitions have come to fruition and potential inaccuracies below the 10⁻¹⁷ level have been demonstrated. Such standards point to the future of time keeping and much development is being pursued to realise the potential of these 'next generation' optical clocks. One such approach, on which this work focusses, relies on a 'magic' wavelength optical lattice trap to provide (almost) Doppler- and recoil-free confinement of atoms during clock interrogation. At this 'magic' wavelength, light induced perturbation of the clock states is equal and so cancels precisely. This thesis describes the design and implementation of an optical lattice frequency standard apparatus based on 88Sr held in a 1D optical lattice. A review of the development of atomic frequency metrology is given from a historical viewpoint and the technology and limitations of current methods discussed. To tackle the blackbody radiation shift, which currently presents the greatest limitation to the Sr lattice clock, imposing at the 10⁻¹⁶ level, a scheme to measure the blackbody radiation shift coefficient at the 10⁻¹⁷ level is developed. Techniques to laser cool and trap atomic strontium are described and the implementation detailed. All laser systems required for clock operation are described including the design and implementation of extended-cavity diode lasers for precision spectroscopy. Details relevant to the eventual operation of the apparatus are discussed.
We optically excite the electronic state 3s3p ^{3}P_{0} in ^{24}Mg atoms, laser cooled and trapped in a magic-wavelength lattice. An applied magnetic field enhances the coupling of the light to the otherwise strictly forbidden transition. We determine the magic wavelength, the quadratic magnetic Zeeman shift, and the transition frequency to be 468.46(21) nm, -206.6(2.0) MHz/T^{2}, and 655 058 646 691(101) kHz, respectively. These are compared with theoretical predictions and results from complementary experiments. We also develop a high-precision relativistic structure model for magnesium, give an improved theoretical value for the blackbody radiation shift, and discuss a clock based on bosonic magnesium.